Using the right buffers is critical for assay performance and reliable results. Our solutions are optimized to support your experiments in a variety of applications. Find the optimal buffers to complement your experiments, either as preassembled kits or individual reagents.
Flow Cytometry
Discover our buffers optimized to help you fix, stain, permeate, or detect proteins in your flow cytometry experiments.
Microscopy
Confidently execute imaging experiments with buffers to clear tissue, improve antibody binding, or boost fluorescent signal.
Immunoassays
Use our ELISA-optimized buffers to coat, wash and block plates for ideal binding and ultimate assay performance.
LEGENDplex™
Confidently execute our bead-based immunoassays by pairing with the right LEGENDplex™ buffer set.
Western Blotting
Trust our Western-Ready™ buffers for every step of your workflow, from protein extraction to detection.
MojoSort™
Achieve peak performance and reduce non-specific binding in your magnetic cell separation system using our buffer.
Beyond antibody reagents, flow cytometry requires the right types of buffers for optimal staining. This convenient list separates out flow cytometry applications by their intended target. It also indicates which buffers are best-suited to your task for surface or intracellular staining and the protocols necessary for each.
Additionally, our Tandem Stabilizer helps to reduce tandem dye de-coupling when added as a supplement to our commonly used buffers for storing stained, fixed cells, as well as those used for fixation and permeabilization procedures.
Tissue/Cells/Whole Blood | Apoptosis (Annexin V) | |
---|---|---|
Surface Staining | Cell Staining Buffer | Annexin Binding Buffer |
Fixation | Fixation Buffer | Fixation Buffer |
Cytokines | FOXP3/Helios/ Transcription Factors |
Phospho Targets | BrdU | |
---|---|---|---|---|
Surface Staining | Cell Staining Buffer | Cell Staining Buffer | Cell Staining Buffer | Cell Staining Buffer |
Fixation |
Cyto-Fast™ Fix/Perm Buffer Set
|
True-Nuclear™ Transcription Factor Buffer Set | Fixation Buffer | Fixation Buffer |
Permeabilization |
Cyto-Fast™ Fix/Perm Buffer Set
|
True-Nuclear™ Transcription Factor Buffer Set | True-Phos™ Permeabilization Buffer | 0.5% Triton-X 100 in PBS |
BioLegend |
BD Biosciences |
420403 7-AAD Viability Staining Solution | 559925 7-AAD Staining Solution |
421301 Propidium Iodide | 556463 Propidium Iodide |
420701 Monensin Solution (1,000X) | 554724 BD™ GolgiStop |
420601 Brefeldin A | 555029 BD™ GolgiPlug |
422201 Annexin V Binding Buffer | 556454 Annexin V Binding Buffer |
420301 RBC Lysis Buffer (10X) | 555899 Lysing Buffer |
422401 RBC Lysis/Fixation Solution (10X) | 558049 Lyse/Fix Buffer 5X |
156603 TruStain FcX™ PLUS (Mouse) | 553141 Mouse Fc Block |
422301 TruStain FcX™ (Human) | 564219 BD Fc Block™ |
420201 Cell Staining Buffer | 554656 Stain Buffer (FBS) |
420801 Fixation Buffer | 554722 BD Cytofix/Cytoperm™ Solution |
421002 Intracellular Staining Permeabilization Wash Buffer (10X) | 554723 Perm/Wash Buffer |
424401 True-Nuclear™ Transcription Factor Buffer Set | 560409/560098 (Mouse/Human) FOXP3 Buffer Set |
422101 FluoroFix™ Buffer | 338036 BD™ Stabilizing Fixative |
422501 Cyto-Last™ Buffer | None |
424401 True-Nuclear™ Transcription Factor Buffer Set | 562574 Transcription Factor Buffer Set |
425401 True-Phos™ Perm Buffer | 558050 BD Phosflow™ Perm Buffer III |
426101 True-Stain Monocyte Blocker™ | None |
426803 Cyto-Fast™ Fix/Perm Buffer Set | 554714 Fixation/Permeabilization Solution Kit |
426105 True-Stain™ Multi-Fluor Buffer | 563794 BD Horizon™ Brillaint Stain Buffer 566385 BD Horizon™ Brillaint Stain Buffer Plus |
True-Stain™ Multi-Fluor Buffer helps prevent interactions between fluorescent reagents when staining cells with multiple Brilliant Violet™ or Brilliant Ultraviolet™ antibody conjugates without reducing their signal. This alternative to BD Horizon™ Brilliant Stain Buffer can help minimize the non-specific interaction of Brilliant polymer dyes, reducing staining artifacts which may affect data interpretation. Consult our technical support team to learn about panel selection and what best practices can be used to further reduce the possibility of non-specific polymer staining. True-Stain Multi-Fluor Buffer is optimized for use with BioLegend protocols and flow cytometry reagents, including fixation and permeabilization reagents and BioLegend compensation beads. Increase confidence in your results with our full array of products.
True-Stain Multi-Fluor Buffer is comparable with BD’s Brilliant Stain Buffer.
Monocytes and macrophages can exhibit non-specific binding of antibodies and fluorophores used in cell surface staining of live cells. BioLegend has now formulated an effective blocking reagent, True-Stain Monocyte Blocker™. This non-antibody based blocking solution has been shown to reduce non-specific monocyte binding due to the fluorophore and does not affect the desirable specific staining of monocytes. Learn more about how True-Stain Monocyte Blocker™ can help you immuno-label monocytes with confidence.
Human PBMCs were stained with 5 µL/test of antibody in 100 µL of cells at 1 x 106 cells/mL with (bottom row)
or without (top row) True-Stain Monocyte Blocker™.
Our Western-Ready™ buffers are easily integrated into your workflow to support protein extraction, gel loading and running, and detection. Explore our Western blot page to learn more about our buffers, protocols and troubleshooting tips!
Follow Us