ELISA MAX™ Deluxe Set Human MCP-1/CCL2

Pricing & Availability
Regulatory Status
RUO
Other Names
Monocyte chemotactic protein 1, chemokine (C-C motif) ligand 2, Ccl2, JE, Scya2, monocyte chemotactic and activating factor, MCAF
Ave. Rating
Submit a Review
Product Citations
publications
MCP-1_Human_edeluxe_032912
  • MCP-1_Human_edeluxe_032912
Cat # Size Price Quantity Check Availability Save
438804 5 plates 244€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Please contact our sales representative for bulk pricing quotations.

Human MCP-1, also known as CCL2, is a member of the CC β chemokine family. It is widely expressed in endothelial cells, smooth muscle cells, and monocytes in response to several atherogenic stimulants such as CD40 ligand, platelet derived growth factor (PDGF), interleukin-1β (IL-1β), and oxidized low density lipoprotein. Several recent in vivo studies have disclosed critical roles of MCP1 in atherosclerosis. In addition, MCP-1 has been implicated in monocytic infiltration of tissues during several inflammatory diseases, and has been implicated in macrophage-mediated tumor growth suppression in mice. MCP-1 has been shown to have direct effects on tumor cells in an autocrine and paracrine fashion in multiple cancers, including breast, lung, cervix, ovary, sarcoma, and prostate. In addition, MCP-1 plays a key role in the regulation of MMPs during transmigration. MCP-1 has been described as a new diagnostic marker and therapeutic target for progressive renal injury in diabetic nephropathy. Kidney epithelial cells, including glomerular podocytes and tubular cells, make MCP-1 in response to high glucose and advanced glycation end products. MCP-1 promotes inflammation and progressive injury in diabetic kidneys.

Both the ELISA MAX™ Standard Set and ELISA MAX™ Deluxe Set are specifically engineered for accurate recovery and measurement of analytes in complex fluids, such as serum and plasma (as well as activated cell cultures) without any interference by confounding serum factors, such as heterophilic antibody or rheumatoid factor.

Product Details
Technical Data Sheet (pdf)

Kit Contents

Kit Contents
  • Human MCP-1/CCL2 ELISA MAX™ Capture Antibody (200X)
  • Human MCP-1/CCL2 ELISA MAX™ Detection Antibody (200X)
  • Human MCP-1/CCL2 Standard
  • Avidin-HRP (1000X)
  • Substrate Solution A
  • Substrate Solution B
  • Coating Buffer A (5X)
  • Assay Diluent A (5X)

Product Details

Verified Reactivity
Human
Application

ELISA

 
As a part of BioLegend's efforts to go green, each new lot of the ELISA MAX™ sets will include a summarized version of its manual. Click here for more information.
Application References

(PubMed link indicates BioLegend citation)
  1. Cho HY, et al. 2015. Cell Immunol. 293:95. PubMed
Product Citations
  1. Cho H, et al. 2015. Cell Immunol. 293:95. PubMed
  2. Veerasubramanian PK, et al. 2021. Bioengineering (Basel). 9:. PubMed
  3. Lee C, et al. 2017. Int J Mol Sci. 10.3390/ijms18071363. PubMed
  4. Gril B, et al. 2018. Nat Commun. 9:2705. PubMed
  5. Zhao Q, et al. 2022. iScience. 25:105319. PubMed
  6. Bader A, et al. 2015. PLoS One. 10: 0138477. PubMed
  7. Li X, et al. 2022. Sci Rep. 12:17058. PubMed
  8. Skejoe C, et al. 2022. Am J Clin Exp Immunol. 11:34. PubMed
Sensitivity
3.9 pg/mL
Standard Range
7.8-500 pg/mL
Materials Not Included
  • Microwell plates: 96-well Nunc MaxiSorp™ is recommended.
  • A microplate reader capable of measuring absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 2 µL to 1 mL
  • Deionized (DI) water
  • PBS (Phosphate-Buffered Saline): 8.0 g NaCl, 1.16 g Na2HPO4, 0.2 g KH2PO4, 0.2 g KCl, add deionized water to 1 L; pH to 7.4, 0.2 µm filtered.
  • Wash Buffer (Phosphate-Buffered Saline (PBS) + 0.05% Tween-20, pH=7.4). BioLegend Cat. No. 421601 is recommended.
  • Wash bottle or automated microplate washer
  • Stop Solution (e.g. 2N H2SO4) Biolegend Cat. No. 423001 is recommended
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Plate Sealer
  • Absorbent paper

Antigen Details

Cell Sources
Endothelial cells, smooth muscle cells, and monocytes
Biology Area
Cell Biology, Neuroinflammation, Neuroscience
Molecular Family
Cytokines/Chemokines
Gene ID
6347 View all products for this Gene ID
UniProt
View information about CCL2 on UniProt.org

Related FAQs

Do the ELISA MAX™ Deluxe Sets come with plates?

No, ELISA MAX™ Deluxe Sets do not come with plates. Coating Buffer and Assay Diluent (for blocking and dilutions) are included in these sets. Plates can be ordered separately (Cat No. 423501), and instructions for coating the plates are in the sets’ product manuals.

Go To Top Version: 5    Revision Date: 09.12.2022

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account