Description

EpCAM (CD326) mediates calcium-independent homophilic cell to cell adhesion. It may also function as a growth factor receptor. It is thought to be involved in maintaining cells in position during proliferation. Expression of EpCAM seems to correlate inversely with the level of E-cadherin (CD324). EpCAM is considered important in tumor biology.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
TE-71 thymic epithelial cell line
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark Blue™ 550 under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage

Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.

Excitation Laser
Blue Laser (488 nm)
Application Notes

Additional reported applications for clone G8.8 (for the relevant formats) include: immunohistochemistry of frozen sections: acetone fixed1, with or without OCT embedding2,4, and spatial biology (IBEX)13,14.

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References

(PubMed link indicates BioLegend citation)
  1. Farr A, et al. 1991. J. Histochem. Cytochem. 39:645. (FC, IHC)
  2. Dooley J, et al. 2005. J. Immunol. 175:4331. (FC, IHC)
  3. Hinterberger M, et. al. 2010. Nat. Immunol. 11:512. (FC) PubMed
  4. Gracz AD, et al. 2010. Am J. Physiol Gastrointest Liver Physiol. 298:590. (IHC) PubMed
  5. Nudel I, et al. 2011. J. Immunol. 186:891. PubMed
  6. Morimoto H, et al. 2012. Biol Reprod. 86:148. PubMed
  7. Ishii K, et al. 2012. Development. 139:1734. PubMed
  8. Takehashi M, et al. 2012. Biol Reprod. 86:178. PubMed
  9. Murakami R, et al. 2013. PLoS One. 8:73270. PubMed
  10. Taguchi K, et al. 2014. Mol Cell Biol. 34:900. PubMed
  11. Hirokawa Y, et al. 2014. Am J Physiol Gastrointerest Liver Physiol. 306:547. PubMed
  12. Ding X, et al. 2015. Cancer Res. 75:330. PubMed
  13. Radtke AJ, et al. 2020. Proc Natl Acad Sci U S A. 117:33455-65. (SB) PubMed
  14. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed

Antigen Details

Structure
40 kD single-pass type 1 glycoprotein. 293 amino acids, with a 21 aa signal peptide, a 246 aa extracellular domain, a 21 aa transmembrane domain, and a 26 aa cytoplasmic domain. The extracellular domain contains two epidermal growth factor-like repeats.
Distribution

Expressed on majority of epithelial cell membranes with the exception of adult squamous cells of the skin and a few specific epithelial cell types.

Function
Mediates calcium-independent homophilic cell-cell adhesion.
Interaction
CD326 displays hemophilic binding.
Ligand/Receptor
CD305 (LAIR-1), CD306 (LAIR-2), and Ep-CAM.
Cell Type
Embryonic Stem Cells, Epithelial cells
Biology Area
Immunology, Stem Cells
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References

1. Borkowski TA, et al. 1996. Eur. J. Immunol. 26:110.
2. Bergsagel PL, et al. 1992. J. Immunol. 148:590.

Gene ID
NA
UniProt
View information about CD326 on UniProt.org

Related FAQs

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

Other Formats

View All CD326 Reagents Request Custom Conjugation
Description Clone Applications
APC anti-mouse CD326 (Ep-CAM) G8.8 FC
Purified anti-mouse CD326 (Ep-CAM) G8.8 FC,IHC-F,ICC
Biotin anti-mouse CD326 (Ep-CAM) G8.8 FC
PE anti-mouse CD326 (Ep-CAM) G8.8 FC
FITC anti-mouse CD326 (Ep-CAM) G8.8 FC
Alexa Fluor® 488 anti-mouse CD326 (Ep-CAM) G8.8 FC,IHC-F,3D IHC
Alexa Fluor® 647 anti-mouse CD326 (Ep-CAM) G8.8 FC,IHC-F,3D IHC,SB
PE/Cyanine7 anti-mouse CD326 (Ep-CAM) G8.8 FC
APC/Cyanine7 anti-mouse CD326 (Ep-CAM) G8.8 FC
PerCP/Cyanine5.5 anti-mouse CD326 (Ep-CAM) G8.8 FC
Alexa Fluor® 594 anti-mouse CD326 (Ep-CAM) G8.8 ICC,IHC-F,3D IHC
Brilliant Violet 421™ anti-mouse CD326 (Ep-CAM) G8.8 FC
Brilliant Violet 605™ anti-mouse CD326 (Ep-CAM) G8.8 FC
Purified anti-mouse CD326 (Ep-CAM) (Maxpar® Ready) G8.8 FC,CyTOF®
APC/Fire™ 750 anti-mouse CD326 (Ep-CAM) G8.8 FC
Brilliant Violet 711™ anti-mouse CD326 (Ep-CAM) G8.8 FC
Brilliant Violet 510™ anti-mouse CD326 (Ep-CAM) G8.8 FC
PE/Dazzle™ 594 anti-mouse CD326 (Ep-CAM) G8.8 FC
TotalSeq™-A0449 anti-mouse CD326 (Ep-CAM) G8.8 PG
Alexa Fluor® 700 anti-mouse CD326 (Ep-CAM) G8.8 FC
TotalSeq™-C0449 anti-mouse CD326 (Ep-CAM) G8.8 PG
Brilliant Violet 785™ anti-mouse CD326 (Ep-CAM) G8.8 FC
TotalSeq™-B0449 anti-mouse CD326 (Ep-CAM) G8.8 PG
Brilliant Violet 650™ anti-mouse CD326 (Ep-CAM) G8.8 FC
PE/Cyanine5 anti-mouse CD326 (Ep-CAM) G8.8 FC
Spark Red™ 718 anti-mouse CD326 (Ep-CAM) (Flexi-Fluor™) G8.8 FC
Spark Blue™ 574 anti-mouse CD326 (Ep-CAM) (Flexi-Fluor™) G8.8 FC
Spark Blue™ 550 anti-mouse CD326 (Ep-CAM) (Flexi-Fluor™) G8.8 FC
Go To Top Version: 1    Revision Date: 09.12.2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account