Spark Blue™ 550 anti-mouse Ly-6G Antibody

Pricing & Availability
Clone
1A8 (See other available formats)
Regulatory Status
RUO
Other Names
Lymphocyte antigen 6 complex, locus G
Isotype
Rat IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
1A8_SB550_Ly-6G_Antibody_032720
C57BL/6 mouse bone marrow cells stained with Ly-6G (clone 1A8) Spark Blue™ 550 (filled histogram) or unstained cells (open histogram). Data shown was gated on myeloid cell population.
  • 1A8_SB550_Ly-6G_Antibody_032720
    C57BL/6 mouse bone marrow cells stained with Ly-6G (clone 1A8) Spark Blue™ 550 (filled histogram) or unstained cells (open histogram). Data shown was gated on myeloid cell population.
Compare all formats See Spark Blue™ 550 spectral data
Cat # Size Price Quantity Check Availability Save
127663 25 µg 109€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
127664 100 µg 296€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Lymphocyte antigen 6 complex, locus G (Ly-6G), a 21-25 kD GPI-anchored protein, is expressed on the majority of myeloid cells in bone marrow and peripheral granulocytes.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Ly-6G transfected EL-4J cell line.
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark Blue™ 550 under optimal conditions.
Concentration
0.5 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.5 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application.

* Spark Blue™ 550 has a maximum excitation of 516 nm and a maximum emission of 540 nm.

Excitation Laser
Blue Laser (488 nm)
Application Notes

While 1A8 recognizes only Ly-6G, clone RB6-8C5 recognizes both Ly-6G and Ly-6C. Clone RB6-8C5 binds with high affinity to mouse Ly-6G molecules and to a lower extent to Ly-6C15. Clone RB6-8C5 impairs the binding of anti-mouse Ly-6G clone 1A815. However, clone RB6-8C5 is able to stain in the presence of anti-mouse Ly-6C clone HK1.416.

Additional reported applications (for the relevant formats) include: immunohistochemistry9 of frozen sections10 and paraffin-embedded sections11, depletion4, 12-14, and spatial biology (IBEX)20,21. The Ultra-LEAF™ purified antibody (Endotoxin < 0.01 EU/µg, Azide-Free, 0.2 µm filtered) is recommended for in vivo studies or highly sensitive assays (Cat. No. 127632, 127649, 127650, 127661 and 127662).

Application References

(PubMed link indicates BioLegend citation)
  1. Fleming TJ, et al. 1993. J. Immunol. 151:2399. (FC)
  2. Daley JM, et al. 2008. J. Leukocyte Biol. 83:1. (FC)
  3. Dietlin TA, et al. 2007. J. Leukocyte Biol. 81:1205. (FC)
  4. Daley J, et al. 2007. J. Leukocyte Biol. doi:10.1189. (Deplete) PubMed
  5. Tadagavadi RK, et al. 2010. J. Immunol. 185:4904. PubMed
  6. Sumagin R, et al. 2010. J. Immunol. 185:7057. PubMed
  7. Guiducci C, et al. 2010. J. Exp Med. 207:2931. PubMed
  8. Fujita M, et al. 2011. Cancer Res. 71:2664. PubMed
  9. Van Leeuwen, et al. 2008. Arterioscler. Thromb. Vasc. Biol. 28:84. (IHC)
  10. Kowanetz M, et al. 2010. P. Natl. Acad. Sci. USA 107:21248. [supplementary data] (IHC)
  11. Esbona K, et al. 2016. Breast Cancer Res. 18:35. (IHC)
  12. Wojtasiak M, et al. 2010. J. Gen. Virol. 91:2158. (FC, Deplete)
  13. Jaeger BN, et al. 2012. J. Exp. Med. 209:565. (Deplete)
  14. Wozniak KL, et al. 2012. BMC Immunol. 13:65 (FC, Deplete)
  15. Ribechini E, et al. 2009. Eur. J. Immunol. 39:3538.
  16. Ng LG, et al. 2011. J Invest. Dermatol. 131:2058. PubMed
  17. Ma C, et al. 2012. J. Leukoc. Biol. 92:1199.
  18. McCartney-Francis, N, et al. 2014. J Leukoc. Biol. 96:917. PubMed
  19. Her Z, et al. 2014. EMBO Mol. Med. 7:24. PubMed
  20. Radtke AJ, et al. 2020. Proc Natl Acad Sci U S A. 117:33455-65. (SB) PubMed
  21. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed
Product Citations
  1. van Elsas MJ, et al. 2023. J Immunother Cancer. 11:. PubMed
RRID
AB_2860671 (BioLegend Cat. No. 127663)
AB_2860671 (BioLegend Cat. No. 127664)

Antigen Details

Structure
A 21-35 kD GPI-anchorded membrane protein
Distribution

Expressed on the majority of myeloid cells in bone marrow and peripheral granulocytes. The monoclonal antibody RB6-8C5 recognizes both Ly-6G and Ly-6C.

Cell Type
Granulocytes, Macrophages, Monocytes
Biology Area
Immunology, Innate Immunity
Antigen References

Fleming TJ, et al. 1993. J. Immunol. 151:2399.

Gene ID
546644 View all products for this Gene ID
UniProt
View information about Ly-6G on UniProt.org

Related FAQs

There are no FAQs for this product.

Other Formats

View All Ly-6G Reagents Request Custom Conjugation
Description Clone Applications
Alexa Fluor® 594 anti-mouse Ly-6G 1A8 IHC-F,SB
Purified anti-mouse Ly-6G 1A8 FC,IHC-F,IHC-P,SB
Biotin anti-mouse Ly-6G 1A8 FC,IHC
FITC anti-mouse Ly-6G 1A8 FC
PE anti-mouse Ly-6G 1A8 FC
Alexa Fluor® 647 anti-mouse Ly-6G 1A8 FC,IHC-F,SB
Pacific Blue™ anti-mouse Ly-6G 1A8 FC
APC anti-mouse Ly-6G 1A8 FC
PerCP/Cyanine5.5 anti-mouse Ly-6G 1A8 FC
PE/Cyanine7 anti-mouse Ly-6G 1A8 FC
Alexa Fluor® 700 anti-mouse Ly-6G 1A8 FC,IHC
APC/Cyanine7 anti-mouse Ly-6G 1A8 FC
Alexa Fluor® 488 anti-mouse Ly-6G 1A8 FC,IHC-F,SB
Brilliant Violet 421™ anti-mouse Ly-6G 1A8 FC,IHC-F
Brilliant Violet 570™ anti-mouse Ly-6G 1A8 FC
Ultra-LEAF™ Purified anti-mouse Ly-6G 1A8 FC,Depletion,IHC
Brilliant Violet 510™ anti-mouse Ly-6G 1A8 FC
Purified anti-mouse Ly-6G (Maxpar® Ready) 1A8 FC,CyTOF®,WB
Brilliant Violet 650™ anti-mouse Ly-6G 1A8 FC
Brilliant Violet 711™ anti-mouse Ly-6G 1A8 FC
Brilliant Violet 605™ anti-mouse Ly-6G 1A8 FC
Brilliant Violet 785™ anti-mouse Ly-6G 1A8 FC
PE/Dazzle™ 594 anti-mouse Ly-6G 1A8 FC
APC/Fire™ 750 anti-mouse Ly-6G 1A8 FC
PerCP anti-mouse Ly-6G 1A8 FC
TotalSeq™-A0015 anti-mouse Ly-6G 1A8 PG
TotalSeq™-C0015 anti-mouse Ly-6G 1A8 PG
TotalSeq™-B0015 anti-mouse Ly-6G 1A8 PG
Spark Blue™ 550 anti-mouse Ly-6G 1A8 FC
Spark NIR™ 685 anti-mouse Ly-6G 1A8 FC
Spark YG™ 593 anti-mouse Ly-6G 1A8 FC
APC/Fire™ 810 anti-mouse Ly-6G Antibody 1A8 FC
PE/Cyanine5 anti-mouse Ly-6G 1A8 FC
PE/Fire™ 810 anti-mouse Ly-6G Antibody 1A8 FC
Spark UV™ 387 anti-mouse Ly-6G 1A8 FC
PE/Fire™ 640 anti-mouse Ly-6G 1A8 FC
Spark YG™ 570 anti-mouse Ly-6G 1A8 IHC-F,FC
Spark Red™ 718 anti-mouse Ly-6G (Flexi-Fluor™) 1A8 FC
Spark Blue™ 574 anti-mouse Ly-6G (Flexi-Fluor™) 1A8 FC
Go To Top Version: 2    Revision Date: 09.14.2020

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account