Brilliant Violet 421™ anti-mouse CD38 Antibody

Pricing & Availability
Clone
90 (See other available formats)
Regulatory Status
RUO
Other Names
T10
Isotype
Rat IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
90_BV421_CD38_Antibody_051718
C57BL/6 mouse splenocytes were stained with CD38 (clone 90) Brilliant Violet 421™ (filled histogram) or Rat IgG2a, κ Brilliant Violet 421™ isotype control (open histogram).
  • 90_BV421_CD38_Antibody_051718
    C57BL/6 mouse splenocytes were stained with CD38 (clone 90) Brilliant Violet 421™ (filled histogram) or Rat IgG2a, κ Brilliant Violet 421™ isotype control (open histogram).
Compare all formats See Brilliant Violet 421™ spectral data
Cat # Size Price Quantity Check Availability Save
102732 50 µg 203€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD38 is a 45 kD type II transmembrane glycoprotein also known as T10. It is an ADP-ribosyl hydrolase expressed at variable levels on hematopoietic cells and in some non-hematopoietic tissues (such as brain, muscle, and kidney). In humans, it is expressed at high levels on plasma cells and activated T and B cells, natural killer (NK) lymphocytes, myeloblasts, and erythroblasts. By functioning as both a cyclase and a hydrolase, CD38 mediates lymphocyte activation, adhesion, and the metabolism of cADPR and NAADP. CD31 is the ligand of CD38.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Mouse bone marrow pre-B cells
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA).
Preparation
The antibody was purified by affinity chromatography and conjugated with Brilliant Violet 421™ under optimal conditions.
Concentration
0.2 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤0.25 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Brilliant Violet 421™ excites at 405 nm and emits at 421 nm. The standard bandpass filter 450/50 nm is recommended for detection. Brilliant Violet 421™ is a trademark of Sirigen Group Ltd.


Learn more about Brilliant Violet™.

This product is subject to proprietary rights of Sirigen Inc. and is made and sold under license from Sirigen Inc. The purchase of this product conveys to the buyer a non-transferable right to use the purchased product for research purposes only. This product may not be resold or incorporated in any manner into another product for resale. Any use for therapeutics or diagnostics is strictly prohibited. This product is covered by U.S. Patent(s), pending patent applications and foreign equivalents.
Excitation Laser
Violet Laser (405 nm)
Product Citations
  1. Kuczynski EA, et al. 2022. EMBO Mol Med. 14:e15816. PubMed
  2. Vilen Z, et al. 2023. ACS Chem Biol. 701:18. PubMed
RRID
AB_2734153 (BioLegend Cat. No. 102732)

Antigen Details

Structure
ADP-ribosyl hydrolase, 42 kD
Distribution

B cells, NK cells, T cell subset, brain, muscle, kidney

Function
Regulation of cellular activation/proliferation, adhesion, metabolism of cADPR and NAADP
Ligand/Receptor
CD31, hyaluronic acid
Antigen References

1. Barclay AN, et al. 1997. The Leukocyte Antigen FactsBook Academic Press.
2. Shubinsky G, et al. 1997. Immunity 7:315.
3. Cesano A, et al. 1998. J. Immunol. 160:1106.
4. Cockayne DA, et al. 1998. Blood 92:1324.

Gene ID
12494 View all products for this Gene ID
UniProt
View information about CD38 on UniProt.org

Related FAQs

What is the F/P ratio range of our BV421™ format antibody reagents?

It is lot-specific. On average it ranges between 2-4.

Go To Top Version: 1    Revision Date: 05.17.2018

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account