Description

Macrophage migration inhibitory factor (MIF), also known as glycosylation inhibiting factor (GIF), is a pituitary hormone and a macrophage- and T cell-derived cytokine that plays an important role in the endocrine and immune systems. MIF consists of 115 amino acids and has a molecular weight of 12.5 kD. Mouse MIF shares most of its identity with human (90%), rat (99%), and cattle (88%) MIFs, and a moderate percentage of its identity with MIFs from a wide variety of other species. It exists in monomeric, dimeric, and trimeric forms of identical protomers.

MIF is active as a pro-inflammatory regulator and upregulates multiple cytokines that are vital to combating infections in vivo, including tumor-necrosis factor (TNF), interferon-γ (IFN-γ), and interleukin-12 (IL-12). It is known to maintain cell survival and promote pro-inflammatory immune responses. MIF also activates the ERK1/ERK2 signaling pathway, which inhibits the immunosuppressive effects of glucocorticoids. MIF also plays a critical role in superantigen-induced toxic shock. It upregulates several factors that enhance the growth and invasiveness of gram-negative bacteria. MIF can enhance many inflammatory diseases, such as acute respiratory distress syndrome, arthritis, atopic dermatitis, allograft rejection, glomerulonephritis, inflammatory bowel diseases, asthma, and atherosclerosis. Known receptors for MIF include CXCR2, CXCR4, CD44, and CD74.

The LEGEND MAX™ Mouse MIF ELISA kit is a ready-to-use Sandwich Enzyme-Linked Immunosorbent Assay (ELISA) with a 96-well strip plate that is pre-coated with a rat monoclonal anti-mouse MIF antibody. The Detection Antibody is a biotinylated goat polyclonal anti-mouse MIF antibody. This assay is specifically designed to quantify mouse MIF from serum, plasma, cell culture supernatant, and cell lysate. This kit is analytically validated with prepared reagents.

Product Details
Technical data sheet

Kit Contents

Kit Contents
  • Anti-Mouse MIF Pre-coated 96 well Strip Microplate
  • Mouse MIF Detection Antibody
  • Mouse MIF Standard
  • Avidin-HRP
  • Assay Buffer B
  • Wash Buffer (20X)
  • Substrate Solution F
  • Stop Solution
  • Plate Sealers

Product Details

Verified Reactivity
Mouse
Application

ELISA

Product Citations
  1. Stanfield BA, et al. 2021. PLoS One. 16:e0245169. PubMed
Sensitivity
25.28 ± 1.68 pg/mL
Standard Range
156 - 10,000 pg/mL
Materials Not Included
  • Microplate reader able to measure absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 1 µL to 1,000 µL
  • Deionized water
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Plate shaker
  • Polypropylene vials

Antigen Details

Biology Area
Angiogenesis, Apoptosis/Tumor Suppressors/Cell Death, Cell Biology, Cell Cycle/DNA Replication, Immunology, Innate Immunity, Signal Transduction
Molecular Family
Cytokines/Chemokines
Gene ID
17319 View all products for this Gene ID
UniProt
View information about MIF on UniProt.org

Related FAQs

In your LEGEND MAX™ ELISA Kits, there is a step that calls for washing the plates before adding sample. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The additional washing step is designed to remove these components before you start the assay. If you do not perform the washing, the effect on assay performance is negligible.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The wash buffer provided in all our LEGEND MAX™ kits is the same and the part numbers on the wash buffer bottles in these kits should be identical. For ELISA MAX™ Deluxe and ELISA MAX™ Standard Sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

In some cases, dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

Go To Top Version: 2    Revision Date: 11.03.2016

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account