MojoSort™ Mouse CD4 Naïve T Cell Isolation Kit

Pricing & Availability
Regulatory Status
RUO
Ave. Rating
Submit a Review
Product Citations
publications
MojoSort_Mouse_CD4_Naive_T_Cell_Isolation_Kit_1_09142016
The MojoSort™ Mouse CD4 Naïve T cell Isolation Kit was used to isolate cells from C57BL/6 mouse spleen. Top: CD4+T cells after isolation. Middle: CD4+ Naïve T cells after isolation, defined by the CD62L (clone: MEL-14) PE and CD44 (clone: IM7) FITC profile. Bottom: cells before isolation, stained with CD4 (clone: GK1.5) Brilliant Violet 785™ and CD3 (clone: 17A2) APC. Dead cells were excluded by 7-AAD.
  • MojoSort_Mouse_CD4_Naive_T_Cell_Isolation_Kit_1_09142016
    The MojoSort™ Mouse CD4 Naïve T cell Isolation Kit was used to isolate cells from C57BL/6 mouse spleen. Top: CD4+T cells after isolation. Middle: CD4+ Naïve T cells after isolation, defined by the CD62L (clone: MEL-14) PE and CD44 (clone: IM7) FITC profile. Bottom: cells before isolation, stained with CD4 (clone: GK1.5) Brilliant Violet 785™ and CD3 (clone: 17A2) APC. Dead cells were excluded by 7-AAD.
  • MojoSort_Mouse_CD4_Naive_T_Cell_Isolation_Kit_2_09142016
  • MojoSort_Mouse_CD4_Naive_T_Cell_Isolation_Kit_3_09142016
Cat # Size Price Quantity Check Availability Save
480039 20 tests 186€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
480040 200 tests 592€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Non CD4+ Naïve T cells are depleted by incubating your sample with the biotin antibody cocktail followed by incubation with magnetic Streptavidin Nanobeads. The magnetically labeled fraction is retained by the use of a magnetic separator. The untouched CD4+ Naïve T cells are collected by decanting the liquid in a clean tube. These are your cells of interest; do not discard the liquid. Some of the downstream applications include functional assays, gene expression, phenotypic characterization, etc.

MojoSort™ reagents are also compatible with column-based cell separation systems available from other vendors. Optimized protocols for cell separation using columns from in-house testing are provided for each kit under the “Related Protocols” section, as well as representative data on the product webpage (where available). Data generated using column separators are indicated on the figure legend.

Due to the property of the beads, MojoSort™ reagents typically require dilution for optimal use on column separators. Where available, recommended dilution factors for each kit component based on in-house testing are provided under the “Application Notes” section of the webpage.

Product Details
Technical data sheet

Kit Contents

Kit Contents

For Cat# 480039:
 

• 200 µl Biotin-Antibody Cocktail
• 200 µl Streptavidin Nanobeads

 

For Cat# 480040:
 

•  2 vials of 1 ml Biotin-Antibody Cocktail each
•  2 vials of 1 ml Streptavidin Nanobeads each

 

Product Details

Verified Reactivity
Mouse
Formulation
Cocktail: Phosphate buffer solution containing 0.09% sodium azide, pH 7.2.
Streptavidin Nanobeads: Aqueous solution containing BSA and 0.05% sodium azide.
Preparation
The antibodies were purified by affinity chromatography, and conjugated with biotin under optimal conditions.
Strepavidin Nanobeads: Streptavidin-coated magnetic beads.
Storage & Handling
Antibody cocktail and Streptavidin Nanobeads should be stored undiluted between 2°C and 8°C.
Application

Cell Separation (MojoSort™) - Quality tested

Recommended Usage

10 µl of antibody cocktail for 1 x 107 cells in 100 µl of buffer.
10 µl of Streptavidin Nanobeads for 1 x 107 cells in 100 µl of buffer.

Application Notes

This kit is designed for the isolation of untouched naïve CD4+ T cells from lymphoid tissues. For optimal results, we recommend incubating the sample in PBS without Ca/Mg on ice for 30 minutes at the final step of the sample preparation procedure. See the protocols for further instructions.

Each lot has been individually optimized. Do not mix and match components from different lots or different kits.

Antibody or cocktail dilution to use in column: 8X
Nanobead dilution to use in columns: 5X

Product Citations
  1. Dou D, et al. 2021. Clin Sci (Lond). 135:597. PubMed
  2. Hsieh T, et al. 2022. Front Immunol. 13:901030. PubMed
  3. Chen C, et al. 2022. Sci Adv. 8:eabo4363. PubMed
  4. Guo F, et al. 2022. Appl Microbiol Biotechnol. 106:7643. PubMed
  5. Reticker-Flynn NE, et al. 2022. Cell. 185:1924. PubMed
  6. Kodama N, et al. 2023. Front Nutr. 10:1081263. PubMed
  7. Sang H, et al. 2023. Adv Clin Exp Med. 32:551. PubMed
  8. Kiritsy MC, et al. 2021. Elife. 10:. PubMed
  9. Kang S, et al. 2021. Bio Protoc. 11:e4029. PubMed
  10. Dong L, et al. 2017. Sci Rep. 10.1038/srep36598. PubMed
  11. Duan H, et al. 2021. J Clin Invest. 131:. PubMed
  12. Tian M, et al. 2021. Elife. 10:. PubMed
  13. Nagata K, et al. 2021. Front Immunol. 12:730706. PubMed
  14. Feng P, et al. 2021. Theranostics. 11:9503. PubMed
  15. Blaszczak AM, et al. 2020. Immunometabolism. 2:00. PubMed
  16. Jain A, et al. 2020. Nat Immunol. 0.920138889. PubMed
  17. Lee WH, et al. 2019. Exp Mol Med. 51:143. PubMed
  18. Wang N, et al. 2020. Front Immunol. 1.765972222. PubMed

Antigen Details

Biology Area
Immunology
Molecular Family
CD Molecules
Gene ID
NA
UniProt
View information about CD4 on UniProt.org

Related FAQs

Is there a way to detach your magnetic particles from the cell surface?

MojoSort™ Nanobeads: These magnetic particles cannot be removed from cells. This includes standalone Nanobeads and MojoSort kits using Nanobeads. We have found that cells are functional without the need to detach the magnetic Nanobeads.

 

MojoSort Microbeads: These magnetic particles may be released following the detailed product-specific protocol.

What is the size of your magnetic particles?

MojoSort Nanobeads: the average diameter is approximately 130 nm.

 

MojoSort Microbeads: the average diameter is approximately 1 μm.

Are MojoSort™ Nanobeads compatible with other commercially available magnetic separation systems?

MojoSort™ magnetic particles can be used with other commercially available magnetic separators, both free standing magnets and column-based systems. Because MojoSort™ protocols are optimized for the MojoSort™ separator, the protocols may need to be adjusted for other systems.  Please contact BioLegend Technical Service for more product-specific information and guidance. We do not recommend using MojoSort™ particles for BD’s IMag™ or Life Technologies’ DynaMag™.

What antibodies are present in the depletion cocktails provided for isolation kits?

Please contact our technical service team for further assistance.

Go To Top Version: 5    Revision Date: 01.26.2022

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account