Spark Red™ 718 anti-mouse CD206 (MMR) (Flexi-Fluor™) Antibody

Pricing & Availability
Clone
C068C2 (See other available formats)
Regulatory Status
RUO
Other Names
MMR (macrophage mannose receptor), MR (mannose receptor), MRC1
Isotype
Rat IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Save
285215 50 µg 231€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD206, also known as mannose receptor (MR), is a 175 kD type I membrane protein. It is a pattern recognition receptor (PRR) belonging to the C-type lectin superfamily. MR is expressed on macrophages, dendritic cells, Langerhans cells, and hepatic or lymphatic endothelial cells. MR recognizes a range of microbial carbohydrates bearing mannose, fucose, or N-acetyl glucosamine through its C-type lectin-like carbohydrate recognition domains, sulfated carbohydrate antigens through its cysteine-rich domain, and collagens through its fibronectin type II domain. MR mediates endocytosis and phagocytosis as well as activation of macrophages and antigen presentation. It plays an important role in host defense and provides a link between innate and adaptive immunity. Recently, MR on lymphatic endothelial cells was found to be involved in leukocyte trafficking and a contributor to the metastatic behavior of cancer cells. It suggests that MR may be a potential target in controlling inflammation and cancer metastasis by targeting the lymphatic vasculature.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Recombinant mouse CD206 (MMR)
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark Red™ 718 under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage

Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.

Excitation Laser
Red Laser (633 nm)
Application Notes

Clone C068C2 recognizes a region similar to clone MR5D3, based on the ability of the clones to block each other. Additional reported applications (for the relevant formats) include: spatial biology (IBEX)4,5.

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References

(PubMed link indicates BioLegend citation)
  1. Keller J, et al. 2012. Biochem Biophys Res Commun. 417:217. PubMed
  2. Ito H, et al. 2012. J Am Soc Nephrol. 23:1797. PubMed
  3. Yang X, et al. 2015. PNAS. 112:2900. PubMed
  4. Radtke AJ, et al. 2020. Proc Natl Acad Sci U S A. 117:33455-65. (SB) PubMed
  5. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed
RRID
AB_3662451 (BioLegend Cat. No. 285215)

Antigen Details

Structure
Type I transmembrane protein, 175 kD, C-type lectin superfamily
Distribution

Macrophages, dendritic cells, Langerhans cells, liver endothelial cells

Function
Pathogen recognition, endocytosis and phagocytosis, antigen presentation
Ligand/Receptor
Antigen containing mannose, fucose, or an N-acetyl glucosamine
Cell Type
Dendritic cells, Endothelial cells, Langerhans cells, Macrophages
Biology Area
Cell Biology, Immunology, Innate Immunity, Signal Transduction
Molecular Family
CD Molecules
Antigen References

1. Wileman TE, et al. 1986. P. Natl. Acad. Sci. USA 83:2501.
2. Apostolopoulos V, et al. 2001. Curr. Mol. Med. 1:469.
3. Burgdorf S, et al. 2006. J. Immunol. 176:6770.
4. McKenzie EJ, et al. 2007. J. Immunol. 178:4975.

Gene ID
NA
UniProt
View information about CD206 on UniProt.org

Related FAQs

Why is mouse CD206 stained intracellularly and not via surface staining?

Typically, mouse CD206 surface level is relatively low under normal conditions and so intracellular staining protocol is required to get better signal.

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

Go To Top Version: 1    Revision Date: 08.30.2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account