Spark YG™ 581 anti-human CD14 Antibody

Pricing & Availability
Clone
63D3 (See other available formats)
Regulatory Status
RUO
Other Names
Monocyte differentiation antigen CD14, myeloid cell-specific leucine-rich glycoprotein, LPS receptor
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
63D3_SparkYG581_CD14_Antibody_1_110223
Human peripheral blood monocytes were stained with anti-human HLA-DR (clone L243) APC/Cyanine7 and anti-human CD14 (clone 63D3) Spark YG™ 581 (left) or mouse IgG1, κ Spark YG™ 581 isotype control (right).
  • 63D3_SparkYG581_CD14_Antibody_1_110223
    Human peripheral blood monocytes were stained with anti-human HLA-DR (clone L243) APC/Cyanine7 and anti-human CD14 (clone 63D3) Spark YG™ 581 (left) or mouse IgG1, κ Spark YG™ 581 isotype control (right).
Compare all formats See Spark YG™ 581 spectral data
Cat # Size Price Quantity Check Availability Save
367159 25 tests 104€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
367160 100 tests 260€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD14 is a 53-55 kD glycosylphosphatidylinositol (GPI)-linked membrane glycoprotein that is also known as the LPS receptor. CD14 is expressed at high levels on monocytes and macrophages, and at lower levels on granulocytes. Some dendritic cell populations such as interfollicular dendritic cells, reticular dendritic cells, and Langerhans cells have also been reported to express CD14. As a high-affinity receptor for LPS, CD14 is involved in the clearance of gram-negative pathogens and in the upregulation of adhesion molecules and cytokine expression in monocytes and neutrophils.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Purified human peripheral blood monocytes.
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA)
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark YG™ 581 under optimal conditions.
Concentration
Lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

* Spark YG™ 581 has a maximum excitation of 562 nm and a maximum emission of 581 nm.

Excitation Laser
Green Laser (532 nm)/Yellow-Green Laser (561 nm)
Application References

(PubMed link indicates BioLegend citation)
  1. Fridlender ZG, et al. 1999. Hum. Immunol. 11:1028.
  2. Devitt A, et al. 1998. Nature 6675:505.
RRID
AB_3097301 (BioLegend Cat. No. 367159)
AB_3097301 (BioLegend Cat. No. 367160)

Antigen Details

Structure
GPI-linked membrane glycoprotein.
Distribution

Monocytes, macrophages, dendritic cells, and granulocytes.

Function
LPS receptor, clearance of Gram-negative pathogens.
Interaction
LPS.
Ligand/Receptor
LPS.
Cell Type
Dendritic cells, Granulocytes, Macrophages, Monocytes, Neutrophils
Biology Area
Cell Biology, Immunology, Neuroinflammation, Neuroscience
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References
  1. Stocks SC, et al. 1990. Biochem. J. 268:275.
  2. Wright SD, et al. 1990. Science 4975:1431.
Gene ID
929 View all products for this Gene ID
UniProt
View information about CD14 on UniProt.org

Related FAQs

There are no FAQs for this product.
Go To Top Version: 1    Revision Date: 11.02.2023

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account