Uncover unique phenotypes and understand protein expression on a single-cell level with TotalSeq™ oligo-conjugated antibodies. Seamlessly integrate these reagents into existing single-cell sequencing protocols for simultaneous characterization of protein and RNA. Explore the capabilities of proteogenomic analysis and how TotalSeq™ reagents can enable highly multiplexed single-cell protein studies for novel applications in precision medicine, oncology, immunology, neuroscience, and stem cell research.

 

TotalSeq™ format antibodies are patent pending proprietary technologies of BioLegend. Contact us if you are interested in partnering with us around this technology.


TotalSeq™ Reagents for Single-Cell Protein and RNA Detection


TotalSeq™ oligo-conjugated antibodies enable measurement of proteins at a single-cell level and integrate seamlessly into existing single-cell RNA sequencing workflows, including Drop-Seq and those available from 10x Genomics.


Simultaneous Multiomic Data Generation: Increase the power of single-cell experiments by combining proteomic and transcriptomic data.

Reduced Dropouts: In contrast to mRNA, TotalSeq™-derived antibody tags are not highly prone to dropouts, which are essentially false negative readouts.
 

Ultra-High Parameter Surface and Intracellular Protein Detection: Detect hundreds of proteins in a single cell.  A lower dropout rate contributes to enhanced sample clustering and the ability to better identify specific cell types.

 

Diverse applications: With a wide-range of mouse and human targets available, you can use TotalSeq™ antibodies in a variety of research areas, including:

  • Personalized or Precision Medicine
  • Cancer Research
  • Stem Cell Research
  • Basic and Applied Immunology
  • Biomarker Discovery
  • Characterization of New or Rare Cell Types
  • Neuroimmunology
  • Vaccine Research
 
Buyer is solely responsible for determining whether Buyer has all intellectual property rights that are necessary for Buyer's intended uses of the BioLegend TotalSeq™ products. For example, for any technology platform Buyer uses with TotalSeq™, it is Buyer's sole responsibility to determine whether it has all necessary third party intellectual property rights to use that platform and TotalSeq™ with that platform.

Explore Additional Resources

 

Visit our 10x Genomics partnership page to learn how our TotalSeq reagents integrate with their single-cell solutions. 

 

Access our optimized protocols for staining of surface and intracellular proteins specifically developed for use with our TotalSeq reagents for CITE-Seq applications. Explore our full list of TotalSeq antibodies for surface proteins and intracellular proteins

 

For more information regarding the development of the CITE-Seq methodology, check out the CITE-Seq website.  

 

Discover how our TotalSeq™️ reagents and recombinant proteins can be used to build antigen multimers to characterize B cell response to infection with LIBRA-seq.

Highlighted Publications

 

Multi-Omics Resolves a Sharp Disease-State Shift between Mild and Moderate COVID-19

Su Y. et al. Cell. 2020; October. DOI: 10.1016/j.cell.2020.10.037

 

A major study aimed at performing multiomic analyses to characterize immune responses from COVID-19 patients. Using a panel of over 190 TotalSeq™ antibodies, this study identified novel immune cell populations that emerge in patients experiencing moderate COVID-19 severity that are expanded in severe cases. Additionally, the study identified changes within plasma metabolite profiles of patients experiencing severe COVID-19 disease that indicate that depletion of certain metabolites is correlated with the development of severe disease.

 

 

A Conserved Dendritic Cell Regulatory Program Limits Antitumour Immunity

Maier B, et al. Nature. 2020; doi: 10.1038/s41586-020-2134-y.

 

Immune checkpoint blockade is a recent cancer treatment method that induces a durable antitumor response. This therapy aims to mitigate the tolerogenic immune response induced by dendritic cells upon presentation of tumor antigen to T cells. However, it is only effective in a limited subset of cancer patients. This study aims to understand the mechanism by which enhancement of systemic antitumor T cell immunity occurs after neoadjuvant PD-L1 blockade. Through the use of single-cell proteogenomics, the authors identify a dendritic cell regulatory program that limits antitumor activity and is induced by expression of IL-4. Blockade of IL-4 results in increased antitumor responses, suggesting a potential treatment for the improvement of immune checkpoint therapy. 

Discover Antibody-Oligo Formats

 

Each TotalSeq™ antibody is conjugated to a unique oligonucleotide containing a capture sequence, a clone-specific barcode sequence, and a PCR handle compatible with Illumina® sequencing reagents and instruments. Barcodes are placed between the PCR handle and 3’ flanking sequence. The oligonucleotide sequence that is conjugated to our TotalSeq™ antibodies is also referred to as an Antibody-Derived Tag, or ADT. The oligo sequence that is conjugated to our hashtag reagents is referred to as a Hashtag Oligonucleotide, or HTO.

 

For single-cell protein and RNA analysis, we offer TotalSeq™-A, -B, and –C formats and continue to work with compatible partners to support new versions of genomics reagents and solutions. 

Understand the Differences Between TotalSeq™ Formats

 

TotalSeq™-A: Designed to work with any sequencing platform that relies on poly(dT) oligonucleotides as the mRNA capture method.  TotalSeq™-A antibodies contain a poly(A) sequence which mimics a natural mRNA.

 

TotalSeq™-B: Capture sequence is compatible with 10x Genomics Chromium Single Cell Expression Solution 3’ kit with Feature Barcode Technology (v3 or v3.1).

 

TotalSeq™-C: Capture sequence is compatible with the 10x Genomics Chromium Single Cell Immune Profiling Solution (5’) which allows for immune repertoire profiling of T and B cell receptors at a single-cell resolution.

10x Genomics' Solutions, compatible with TotalSeq™-B and –C  antibodies, contain all necessary reagents to process and amplify oligos derived from both TotalSeq™ reagents and mRNA. When using TotalSeq™-A reagents with the 10x Genomics' Single Cell Gene Expression Solution Kits (v2, v3, v3.1), additional reagents for preparation of libraries must be purchased. Please refer to our protocols for a complete list.

 

  TotalSeq™-A TotalSeq™-B TotalSeq™-C
10x Genomics compatibility Single Cell Gene Expression Solution (3’, v2 and v3) and any system employing the poly(A) tail capture method Single Cell Gene Expression Solution (3’, v3 or v3.1) with Feature Barcoding Technology and 10x Genomics Data Analysis Software1 Single Cell Immune Profiling Solution (5’) with Feature Barcoding technology and 10x Genomics Data Analysis Software1
PCR handle CCTTGGCACCCGAGAATTCCA GTGACTGGAGTTCAGACGTGTGCTCTTCCGATCTNNNNNNNNNN2 CGGAGATGTGTATAAGAGACAGNNNNNNNNNN
Capture sequence Poly-A [(A)30*A*A3] NNNNNNNNNGCTTTAAGGCCGGTCCTAGC*A*A4 NNNNNNNNNCCCATATAAGA*A*A4
Next-generation sequencing compatibility Compatible with Illumina instruments Compatible with Illumina instruments Compatible with Illumina instruments

 

Notes:

  1. 10x Genomics' Data Analysis Software does not support cell hashing analysis.
  2. N represents a randomly selected A, C, G, or T.
  3. The symbol * indicates a phosphorothioated bond, to prevent nuclease degradation.
  4. These sequences are unique to the TotalSeq™-B and -C conjugates, and were developed independently of the reagents used by researchers at the New York Genome Center (NYGC, CITE-seq.com). TotalSeq™-B, -C, and the antibodies used by NYGC are all compatible with 10x Genomics' Solutions, but utilize different oligo sequences. As such, protocols and additional reagents, including required primers, differ between the antibody formats. Please refer to our protocols when using TotalSeq™ reagents.

Overview of the TotalSeq™ Workflow

 

 

Protocol: Using TotalSeq™ Antibodies for CITE-Seq

 

Using TotalSeq™ Antibodies for CITE-Seq

 

The DepleteX® Single Cell Boost Kit can be paired with CITE-Seq single-cell workflows that utilize TotalSeq™ oligo-conjugated antibodies from BioLegend for protein detection.

TotalSeq™-B Reagents for Intracellular Cytoplasmic and Cell Surface Staining

 

Intracellular proteins contribute to a host of cellar functions including cell growth, gene regulation, chemotaxis, and immunomodulation. Measuring both intracellular and surface proteins at the single-cell level can give researchers a comprehensive understanding of the cell and the molecular processes that underlie cellular function.

 

The ability to detect cell surface proteins with gene expression in single-cell analysis has been well established using CITE-Seq. However, detecting intracellular proteins while preserving RNA quality for gene expression profiling has proven challenging, due largely to the conditions utilized to access the intracellular compartment of cells which can have deleterious effects on RNA quality. 

 

With advancements in single-cell RNA technology and workflow optimization, it is now possible to observe all 3 modalities using TotalSeq antibodies and our TotalSeq™-B or -C Cell Surface and Intracellular Cytoplasmic Protein Staining with 10x Chromium Single Cell Gene Expression Flex.

 

Why add intracellular targets to your single-cell experiment? 

  • Improve cell characterization by identifying functional molecules. 
  • Add depth to cell state identification by understanding signaling pathways. 
  • Discover unique and new phenotypes within seemingly homogeneous cell populations. 

 

Our full protocol compatible with surface protein expression is now available.

 

TotalSeq™ Format Compatibility

 

 

Assay Compatibility

 

TotalSeq Format Compatibility

TotalSeq-B

Single Cell Assay Compatibility

Chromium Single Cell Gene Expression Flex

Chromium Fixed RNA Profiling Reagent Kits for Singleplexed Samples With Feature Barcode technology for Protein

BioLegend TotalSeq Intracellular Staining Protocol

TotalSeq™-B or -C Cell Surface and Intracellular Cytoplasmic Protein Staining with 10x Chromium Single Cell Gene Expression Flex

Instrument Compatibility

Chromium X Series

Description

Probe based whole transcriptome gene expression, compatible with fresh or fixed samples

Additional Cellular Features

Surface and Intracellular Proteins

Multiplexing Compatibility

TotalSeq-B Hashtags

 

 *Use of  the TotalSeq-B Cell Surface and Intracellular Cytoplasmic Protein Staining with 10x Chromium Single Cell Gene Expression Flex Protocol and our cell hashing reagents with 10x Single Cell Gene Expression Flex is not officially supported by 10x Genomics. For additional information regarding use of TotalSeq-B or TotalSeq Hashtags please contact BioLegend Technical Support.

 

Workflow

 

Required User Guides and Support

 

TotalSeq Format

TotalSeq-B

BioLegend TotalSeq Intracellular Staining Protocol

TotalSeq™-B or -C Cell Surface and Intracellular Cytoplasmic Protein Staining with 10x Chromium Single Cell Gene Expression Flex

10x User Guides

Fixation of Cells & Nuclei for Chromium Fixed RNA Profiling

Chromium Fixed RNA Profiling Reagent Kits for Singleplexed Samples With Feature Barcode technology for Protein

10x General Support

Single Cell Gene Expression Flex

 

TotalSeq Reagents

 

TotalSeq-B: Capture sequence is compatible with capture sequence 1 found on the Single Cell 3' v3.1 Gel Beads used with the 10x Genomics Chromium Single Cell Gene Expression solution and 10x Genomics Single Cell Gene Expression Flex solution with Cell Surface Protein Labeling.

 

TotalSeq Intracellular Antibodies

TotalSeq-B Intracellular

Cocktails

TotalSeq-B Cocktails

Hashtags

TotalSeq-B Hashtags

All Products

TotalSeq-B

 

Additional TotalSeq Resources

TotalSeq Resources and Learning - View all our TotalSeq resources including training videos, protocols, and app notes.

Barcode Look-Up - Access our barcode look-up table to view and export barcode information for all of our TotalSeq reagents.

 

Intracellular and Surface Staining Representative Data

 

Multiplex Samples with Hashtag Antibodies

 

Cell Hashing

To pool multiple samples prior to loading them onto a platform capable of single-cell isolation, try one of our hashtag reagents. Each pre-mixed, ready-to-use hashtag reagent contains a pool of antibodies designed to recognize ubiquitously expressed cell surface markers and is conjugated to a unique barcode. For human samples, our hashtag reagents recognize CD298 and β2-Microglobulin, and for mouse samples, hashtag antibodies recognize CD45 and H-2 MHC Class I.

 

Benefits of using cell hashing:

  • Robust multiplet identification.
  • Minimize variability and reduce batch effects between samples.
  • Pool smaller samples to reach minimal cell numbers.

 

Read more about cell hashing and how they can be used to multiplex samples in the initial paper by Stoeckius M, et al.

Tech Insights: Cell Hashing with TotalSeq™ Reagents

Multiplexing samples in single-cell experiments improves sample throughout and provides cost savings. Learn from Nathan Lucas, PhD, as he describes the benefits and technical considerations for our TotalSeq™ hashtag reagents.

Nuclei Hashing

In addition to single-cell analysis in whole and intact cells, single-nucleus analysis makes it possible to characterize cellular states and physiology in tissues that are challenging to dissociate. This includes tissues that are rich in certain cell types like neurons, adipocytes and muscle cells. Single-nucleus analysis can also help when tissue storage is required, as it is difficult to recover and obtain single-cell suspensions from archived frozen material.

 

To pool isolated nuclei from different samples, we developed nuclear hashing reagents. Our nuclear hashtag antibodies recognize a family of nuclear pore complex proteins and can cross-react with vertebrate organisms and other invertebrate species, such as Xenopus and yeast.

 

Read more about single nucleus hashing analysis in a Nature Communications paper first describing the technology by Gaublomme, et al.

 

Understand the Differences between Hashtag Formats

 

We offer hashtag reagents in our TotalSeq™-A, B, and –C formats. Hashtag reagents from all formats will function similarly, but the workflow and required primers differ.

 

For TotalSeq™-A reagents, the PCR handle between antibodies and hashtag reagents are different. In practice, this means that you will generate two separate libraries– one for your cell surface markers (referred to as ADTs) and one for hashtag-derived oligos (referred to as HTOs). This is beneficial because the two libraries can be mixed at different ratios prior to sequencing to avoid an excess of reads from the hashtags.

 

For TotalSeq™-B and –C reagents, the PCR handle is the same between both your antibodies of interest and the hashtag antibodies. In practice, this means that the hashtag and antibody libraries must be prepared together. To avoid an excess of HTO readings, we recommend titrating down the hashtag reagents. For more information on how to titrate TotalSeq™ products, read our FAQs.

 

Simplify the Proteogenomics Workflow with Antibody Cocktails

 

Remove the need for additional optimization and minimize variability between experiments using pre-defined TotalSeq™ antibody cocktails. Each single-use tube contains pre-titrated amounts of each lyophilized antibody.

 

Benefits of Using TotalSeq™ Cocktails:

  • Provided in convenient, single-use tubes
  • Pre-titrated antibodies for optimal performance
  • Offer reduced cost when compared to buying individual antibodies
  • Minimize variability between different experiments, different labs, and during longitudinal studies

Characterize Cell Diversity to an Unprecedented Level with Universal Cocktails

 

Take a deeper look at immune cells with our TotalSeq™ Human and Mouse Universal Cocktails. Each cocktail contains over 95 antibodies and their associated isotype controls for large-scale protein detection. Within the cocktail, each antibody has been individually titrated using next-generation sequencing as a read-out to provide optimal discrimination of positive and negative cell populations.

 

Version 2.0 of our TotalSeq-A and C Human Universal Cocktails contain 50 and 63 new antibodies, respectively, allowing for higher dimensionality and a more detailed view of cellular heterogeneity, function, and interactions within complex biological systems. Antibody selection for V2.0 was guided by high-impact peer-reviewed publications and feedback from the scientific community to expand the coverage of surface markers relevant to translational research and immuno-oncology applications.

 

View our entire list of cocktails below and visit the product pages to learn more.

 

Human Universal Cocktails

 

TotalSeq™-A Human Universal Cocktail, V2.0

 

TotalSeq™-C Human Universal Cocktail, V2.0

 

TotalSeq™-A Human Universal Cocktail, V1.0

 

TotalSeq™-B Human Universal Cocktail, V1.0

 

TotalSeq™-C Human Universal Cocktail, V1.0

 

 

Mouse Cocktails

 

 

TotalSeq™-A Mouse Universal Cocktail, V1.0

 

TotalSeq™-B Mouse Universal Cocktail, V1.0

 

TotalSeq™-C Mouse Universal Cocktail, V1.0

 

TotalSeq™-B Mouse Myeloid Cocktail, V1.0

  • This panel has been optimized on enzymatically digested mouse splenocytes for the detection of myeloid lineage cell types.
  • Depletion of lymphoid lineage cells is suggested and critical for detection of rare myeloid cell populations.
  • Compatible with 10x Genomics Chromium Universal 3’ and Flex Gene Expression assays.
  • Contains 76 primary antibodies and 8 isotype controls. Download the full barcode list.
  • Download the complete dataset for the TotalSeq™-B Mouse Myeloid Cocktail, V1.0.

 

 

Representative Data for the TotalSeq-A Human Universal Cocktail, V2.0

 


Major immune cell lineages and selected cell states are identified using the TotalSeq-A Human Universal Cocktail, V2.0. Human peripheral blood mononuclear cells (PBMCs) were stained with the TotalSeq-A Human Universal Cocktail, V2.0, and processed using the 10x Genomics Single Cell 3’ v3.1 feature barcoding kit and Illumina sequencing. Protein count data were transformed and visualized in a UMAP projection overlaid with protein expression levels for each component of the cocktail. Cell clusters were identified based on protein expression only.  Refer to the complete dataset to see all cocktail components profiled on PBMCs under stimulation conditions.​ Refer to the complete dataset to see all cocktail components profiled on PBMCs under stimulation conditions.

 

Representative Data for the TotalSeq™-B Mouse Myeloid Cocktail, V1.0

 

Data shown for a subset of markers in the cocktail; download the complete dataset for all 76 primary targets and 8 isotype controls.


Major immune cell lineages and selected cell states are identified using the TotalSeq™-B Mouse Myeloid Cocktail. Enzymatically dissociated mouse splenocytes were depleted of T and B cell populations, stained with the TotalSeq™-B Mouse Myeloid Cocktail and processed using the 10x Genomics Single Cell 3’ v3.1 feature barcoding kit and Illumina sequencing. Protein count data were transformed and visualized in a UMAP projection overlaid with protein expression levels for each component of the cocktail. Cell clusters were identified based on protein expression only.

Identify Major Immune Cell Types with TBNK Cocktails

 

Our TBNK Panels are designed to identify T, B, and NK cells as defined by the expression of CD3, CD4, CD8, CD11c, CD14, CD16, CD19, CD45, and CD56. The TBNK cocktail is available in TotalSeq™-A, B, or C formats and is compatible with a variety of single-cell platforms.

 

Each cocktail has been optimized using human PBMCs. Using lysed whole blood or additional TotalSeq™ antibodies may require further optimizations. Please contact our technical service group for guidance.

 

Human PBMCs were stained with the TotalSeq™ Human TBNK panel containing antibodies against CD3, CD4, CD8, CD19, CD56, CD14, CD11c, CD16, and processed using the 10x Genomics' Single Cell 3’ v3 feature barcoding kit and Illumina sequencing. Protein count data were transformed and visualized in a UMAP projection overlaid with protein expression levels for each component of the cocktail. Clusters were identified based on protein expression only.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account