Keratin 14 Polyclonal Antibody, Purified

Pricing & Availability
Clone
Poly19053 (See other available formats)
Regulatory Status
IVD
Isotype
Rabbit Polyclonal
1_Poly19053_Purified_Keratin_14_Antibody_IHC_030615
Strong cytoplasmic staining of the epidermis in normal human skin tissue detected with anti-K14 (clone Poly19053).
  • 1_Poly19053_Purified_Keratin_14_Antibody_IHC_030615
    Strong cytoplasmic staining of the epidermis in normal human skin tissue detected with anti-K14 (clone Poly19053).
  • 2_CEIVDImage_V4_021023
  • 3_CEIVD_Symbols_021023
Cat # Size Price Quantity Check Availability Save
905301 100 µL £301
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

This antibody is effective in immunohistochemistry (IHC).

This product may contain other non-IgG subtypes.

Product Details
Instructions for Use - English (PDF) Instructions For Use - French (PDF) Instructions For Use - German (PDF) Instructions For Use - Italian (PDF) Instructions For Use - Portuguese (PDF) Instructions For Use - Spanish (PDF)

Product Details

Product Information

Intended Use:

In Vitro Diagnostic (IVD). Use in immunohistochemistry (IHC) test methods only.

The polyclonal antibody Poly19053 is used for the in vitro examination of frozen or paraffin-embedded human skin tissue sections using immunohistochemistry (IHC) methods for the qualitative identification of Keratin 14. The clinical interpretation of any staining or its absence should be complemented by morphological studies and proper controls and should be evaluated within the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.

Reactivity
Human
Formulation
Phosphate-buffered solution + 0.03% Thimerosal.
Preparation
The antibody was purified by peptide affinity chromatography.
Concentration
1.0 mg/mL
Storage & Handling
When stored at ≤ -20°C, product is stable until the date shown on the label. Avoid repeated freeze-thaw cycles to prevent denaturing the antibody. If thawed and stored between 2°C and 8°C, product is stable for 24 months from the date of thaw or until the expiry date on the label, whichever comes first.
Recommended Usage

Each lot of this antibody is quality control tested by immunohistochemical staining of formalin-fixed parafin-embedded sections of normal human skin. Frozen human skin tisue has been veified during product development

The optimal working dilution should be determined for each specific assay condition.
IHC: 1:1,000 with either biotin based detection systems such as USA Ultra Streptavidin Detection (Cat. No. 929501).

Tissue Sections: Paraffin-embedded tissues, frozen tissues
Pretreatment: For optimal staining, the sections should be pretreated with an antigen unmasking solution such as Citrate Buffer Retrieval solution (Cat. No. 928502).
Incubation: 60 minutes at room temperature

Application References

(PubMed link indicates BioLegend citation)
  1. Wend P, et al. Wnt/?-catenin signalling induces MLL to create epigenetic changes in salivary gland tumours. EMBO J., Jun 2013.
  2. Welm AL, Kim S, Welm BE, Bishop JM. MET and MYC cooperate in mammary tumorigenesis. Proc Natl Acad Sci USA 102(12):4324-9, 2005. [IHC] PubMed
  3. Hu Y, Baud V, Oga T, Kim KI, Yoshida K, Karin M. IKKalpha controls formation of the epidermis independently of NF-kappaB. Nature 410:710-714, 2001.
  4. Yuspa SH, Kilkenny AD, Steinert PM, Roop DR. Expression of murine epidermal differentiation markers is tightly regulated by restricted extracellular calcium concentrations in-vitro. J Cell Biol 109:1207-1217, 1989.
  5. Roop DR, Cheng CK, Titterington L, Meyers CA, Stanley JR, Steinert PM, Yuspa SH. Synthetic peptides corresponding to keratin subunits elicit highly specific antibodies. J Biol Chem 259:8037-8040, 1984.
  6. Liang Y. 2011. Patholog Res Int. 2011:93674. (IHC) PubMed
  7. Easter SL, et al. 2014. PLoS One. 9:113247. (IF, WB) PubMed
  8. Frew IJ, et al. 2008. Mol Cell Biol.28:4536. (IHC) PubMed
  9. Levy V, et al. 2007. FASEB J. 21:1358. (IHC) PubMed
  10. Sengupta A, et al. 2010. PLoS One. 5:12249. (IHC) PubMed
  11. Smith BA, et al. 2012. Genes Cancer.3:550. (IHC) PubMed
RRID
AB_2565048 (BioLegend Cat. No. 905301)
Disclaimer

WARNINGS AND PRECAUTIONS

  1. Use appropriate personal protective equipment and safety practices per universal precautions when working with this reagent. Refer to the reagent safety data sheet.
  2. All specimens, samples and any material coming in contact with them should be considered potentially infectious and should be disposed of with proper precautions and in accordance with federal, state and local regulations.
  3. Do not use this reagent beyond the expiration date stated on the label.
  4. Do not use this reagent if it appears cloudy or if there is any change in the appearance of the reagent as these may be indication of possible deterioration.
Go To Top Version: 9    Revision Date: 07/28/2023

For In Vitro Diagnostic Use. Not for therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account