PerCP/Fire™ 806 Streptavidin

Pricing & Availability
Regulatory Status
RUO
Other Names
Streptavidin- PerCP/Fire™ 806, SAv- PerCP/Fire™ 806, streptavidin PerCP/Fire™ 806
Ave. Rating
Submit a Review
Product Citations
publications
A_PerCP-Fire-806_Streptavidin_Antibody_030124
Human peripheral blood lymphocytes were stained with anti-human CD19 (clone HIB19) PE and biotinylated anti-human CD3 (left) or biotinylated mouse IgG1, κ isotype control (right), followed with SAV-PerCP/Fire™ 806.
  • A_PerCP-Fire-806_Streptavidin_Antibody_030124
    Human peripheral blood lymphocytes were stained with anti-human CD19 (clone HIB19) PE and biotinylated anti-human CD3 (left) or biotinylated mouse IgG1, κ isotype control (right), followed with SAV-PerCP/Fire™ 806.
  • B_PerCPFire806_Streptavidin_Antibody_031924
    Human peripheral blood lymphocytes were stained with biotinylated anti-human CD3 (filled histogram) or biotinylated mouse IgG1, κ isotype control (open histogram), followed with SAV-PerCP/Fire™ 806.
See PerCP/Fire™ 806 spectral data
Cat # Size Price Quantity Check Availability Save
405383 25 µg £134
Check Availability


Need larger quantities of this item?
Request Bulk Quote
405384 100 µg £291
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Streptavidin is a 52.8 kDa tetrameric protein obtained from Streptomyces avidinii. It binds to biotin with a very high affinity and is one of the strongest interactions in nature with a dissociation constant of 10-14 mol/L. It is used to detect biotinylated proteins in a wide range of applications.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human, Mouse, Rat, All Species
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
Streptavidin is conjugated with PerCP/Fire™ 806 under optimal conditions.
Concentration
0.2 mg/mL (concentration relates to the Streptavidin only component of the conjugate)
Storage & Handling
The Streptavidin PerCP/Fire™ 806 solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

This streptavidin product is quality control tested by immunofluorescent staining with flow cytometric analysis. The concentration provided is based upon molecular mass of streptavidin independent of any additional molecular mass that might be added by the PerCP/Fire™ 806 conjugation. For flow cytometric staining, the suggested use of this reagent is ≤ 0.25 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application.

* PerCP/Fire™ 806 has a maximum excitation of 478 nm and a maximum emission of 806 nm.

Excitation Laser
Blue Laser (488 nm)

Related FAQs

There are no FAQs for this product.
Go To Top Version: 1    Revision Date: 03/01/2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account