GMP PerCP/Cyanine5.5 anti-human CD3 Antibody

Pricing & Availability
Clone
SK7 (See other available formats)
Workshop
HCDM listed
Other Names
T3, CD3ε
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
SK7_GMP-PerCPCyanine55_CD3_Antibody_082622
Typical results from human peripheral blood lymphocytes stained either with SK7 PerCP/Cyanine5.5 used at 5 µL/test (filled histogram) or with an isotype control (open histogram).
  • SK7_GMP-PerCPCyanine55_CD3_Antibody_082622
    Typical results from human peripheral blood lymphocytes stained either with SK7 PerCP/Cyanine5.5 used at 5 µL/test (filled histogram) or with an isotype control (open histogram).
Compare all formats See GMP PerCP/Cyanine5.5 spectral data
Cat # Size Price Quantity Check Availability Save
260162 100 tests 396€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD3ε is a 20 kD chain of the CD3/T-cell receptor (TCR) complex, which is composed of two CD3ε, one CD3γ, one CD3δ, one CD3ζ (CD247), and a T-cell receptor (α/β or γ/δ) heterodimer. It is found on all mature T cells, NK T cells, and some thymocytes. CD3, also known as T3, is a member of the immunoglobulin superfamily that plays a role in antigen recognition, signal transduction, and T cell activation.

Product Details
Quality Statement This BioLegend’s GMP-RUO reagent is a fluorochrome-labeled monoclonal antibody single reagent for Research Use Only. Suitable for use in laboratory-developed multicolor flow cytometry tests. Single GMP-RUO products can be used in various multicolor flow cytometry combinations. Laboratory need to establish the GMP-RUO performance characteristics in combination with other reagents in normal and pathological samples.
Technical Data Sheet (pdf)

Product Details

Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing True-Stain Monocyte Blocker™, 0.09% sodium azide and 0.2% (w/v) BSA (origin USA).
Preparation
The antibody was purified by affinity chromatography and conjugated with PerCP/Cyanine5.5 under optimal conditions.
Concentration
100 µg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

* PerCP/Cyanine5.5 has a maximum absorption of 482 nm and a maximum emission of 690 nm. 

Excitation Laser
Blue Laser (488 nm)
Application Notes

Additional reported application (for the relevant formats) include: immunohistochemical staining of frozen tissue sections4,5,8, immunofluorescent staining6, and Western blotting3.

Application References
  1. Kan EA, et al. 1983. J. Immunol. 131:536.
  2. Wood GS, et al. 1985. Am. J. Pathol. 120:371.
  3. Van Dongen JJM, et al. 1988. Blood 71:603. (WB)
  4. Haringman JJ, et al. 2005. Arthritis Res. Ther. 7:R862. (IHC)
  5. Carbone A, et al. 1999. Blood 93:2319. (IHC)
  6. Goval JJ, et al. 2006. J. Histochem. Cytochem. 54:75. (IF)
  7. Rutjens E, et al. 2007. J. Immunol. 178:1702.
  8. Kap Y, et al. 2009. J. Histochem. Cytochem. 57:1159. (IHC)
  9. Yoshino N, et al. 2000. Exp. Anim. (Tokyo) 49:97. (FC)
Disclaimer

GMP RUO Flow Cytometry Antibodies. BioLegend GMP RUO fluorophore conjugated antibodies are manufactured in a dedicated GMP facility and compliant with ISO 13485:2016. For research use only. Not for use in diagnostic or therapeutic procedures. Our processes include:

  • Batch-to-batch consistency
  • Material traceability
  • Documented procedures
  • Documented employee training
  • Equipment maintenance and monitoring records
  • Lot-specific certificates of analysis
  • Quality audits per ISO 13485:2016
  • QA review of released products

Antigen Details

Structure
Ig superfamily, with the subunits of CD3γ, CD3δ, CD3ζ, (CD247) and TCR (α/β or γ/δ) forms CD3/TCR complex, 20 kD
Distribution

Mature T and NK T cells, during thymocyte differentiation

Function
Antigen recognition, signal transduction, T cell activation
Ligand/Receptor
Peptide antigen bound to MHC
Cell Type
NKT cells, T cells, Tregs
Biology Area
Immunology, Innate Immunity
Molecular Family
CD Molecules, TCRs
Antigen References

1. Barclay N, et al. 1993. The Leucocyte FactsBook. Academic Press. San Diego.
2. Beverly P, et al. 1981. Eur. J. Immunol. 11:329.
3. Lanier L, et al. 1986. J. Immunol. 137:2501.

Gene ID
916 View all products for this Gene ID
UniProt
View information about CD3 on UniProt.org

Other Formats

View All CD3 Reagents Request Custom Conjugation
Description Clone Applications
APC/Fire™ 750 anti-human CD3 SK7 FC
Biotin anti-human CD3 SK7 FC,ICC
Purified anti-human CD3 SK7 FC,ICC,IHC-F,WB
FITC anti-human CD3 SK7 FC
PE anti-human CD3 SK7 FC
Alexa Fluor® 488 anti-human CD3 SK7 FC
APC anti-human CD3 SK7 FC
PerCP/Cyanine5.5 anti-human CD3 SK7 FC
PerCP anti-human CD3 SK7 FC
PE/Cyanine7 anti-human CD3 SK7 FC
APC/Cyanine7 anti-human CD3 SK7 FC
Alexa Fluor® 700 anti-human CD3 SK7 FC
Pacific Blue™ anti-human CD3 SK7 FC
Alexa Fluor® 647 anti-human CD3 SK7 FC
Brilliant Violet 510™ anti-human CD3 SK7 FC
Brilliant Violet 421™ anti-human CD3 SK7 FC
Brilliant Violet 605™ anti-human CD3 SK7 FC
Brilliant Violet 711™ anti-human CD3 SK7 FC
FITC anti-human CD3 SK7 FC
PE anti-human CD3 SK7 FC
Brilliant Violet 785™ anti-human CD3 SK7 FC
PE/Dazzle™ 594 anti-human CD3 SK7 FC
Brilliant Violet 750™ anti-human CD3 SK7 FC
TotalSeq™-A0049 anti-human CD3 SK7 PG
PerCP/Cyanine5.5 anti-human CD3 SK7 FC
TotalSeq™-C0049 anti-human CD3 SK7 PG
Spark Blue™ 550 anti-human CD3 SK7 FC
PE/Cyanine7 anti-human CD3 SK7 FC
TotalSeq™-B0049 anti-human CD3 SK7 PG
Alexa Fluor® 660 anti-human CD3 SK7 FC
APC/Fire™ 810 anti-human CD3 SK7 FC
Spark NIR™ 685 anti-human CD3 SK7 FC
PE/Fire™ 640 anti-human CD3 SK7 FC
PE/Fire™ 700 anti-human CD3 SK7 FC
APC anti-human CD3 SK7 FC
PerCP anti-human CD3 SK7 FC
APC/Fire™ 750 anti-human CD3 SK7 FC
GMP FITC anti-human CD3 SK7 FC
PE/Cyanine5 anti-human CD3 Antibody SK7 FC
GMP PE anti-human CD3 SK7 FC
GMP APC anti-human CD3 SK7 FC
GMP PerCP/Cyanine5.5 anti-human CD3 SK7 FC
Spark YG™ 593 anti-human CD3 SK7 FC
GMP PerCP anti-human CD3 SK7 FC
Spark Violet™ 500 anti-human CD3 SK7 FC
Brilliant Violet 650™ anti-human CD3 SK7 FC
Spark Violet™ 500 anti-human CD3 SK7 FC
Spark PLUS UV395™ anti-human CD3 SK7 FC
Go To Top Version: 1    Revision Date: 09/19/2022

For Research Use Only. Suitable for ex vivo cell processing. Not for injection or diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account