PE/Cyanine7 Annexin V

Pricing & Availability
Regulatory Status
RUO
Other Names
Annexin A5
Ave. Rating
Submit a Review
Product Citations
publications
PECyanine7_Annexin-V_kit_042020_updated
Human T leukemia cell line Jurkat, treated (left) or non-treated (right) with BioLegend's anti-human CD95 (EOS9.1) mAb (Cat. No. 305704) for 4 hours, then stained with Annexin V- PE/Cyanine7 and Helix NP™ Green (Cat. No. 425303 at 1.25 nM) in Annexin V Binding buffer for 15 minutes at at 37°C.
  • PECyanine7_Annexin-V_kit_042020_updated
    Human T leukemia cell line Jurkat, treated (left) or non-treated (right) with BioLegend's anti-human CD95 (EOS9.1) mAb (Cat. No. 305704) for 4 hours, then stained with Annexin V- PE/Cyanine7 and Helix NP™ Green (Cat. No. 425303 at 1.25 nM) in Annexin V Binding buffer for 15 minutes at at 37°C.
See PE/Cyanine7 spectral data
Cat # Size Price Quantity Check Availability Save
640949 25 tests 104€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
640950 100 tests 254€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
640951 300 tests 418€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Annexin V (or Annexin A5) is a member of the annexin family of intracellular proteins that binds to phosphatidylserine (PS) in a calcium-dependent manner. PS is normally only found on the intracellular leaflet of the plasma membrane in healthy cells, but during early apoptosis, membrane asymmetry is lost and PS translocates to the external leaflet. Fluorochrome-labeled Annexin V can then be used to specifically target and identify apoptotic cells. Annexin V Binding Buffer (Cat. No. 422201) is recommended for use with Annexin V staining. Annexin V binding alone cannot differentiate between apoptotic and necrotic cells. Therefore, we recommend using our Helix NP™ Blue (Cat. No. 425305), Helix NP™ Green (Cat. No. 425303) or Helix NP™ NIR (Cat. No. 425301). Early apoptotic cells will exclude 7-AAD and PI, while late stage apoptotic cells and necrotic cells will stain positively, due to the passage of these dyes into the nucleus where they bind to DNA.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human, Mouse, Rat
Reported Reactivity
Other Species
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA)
Preparation
The antibody was purified by affinity chromatography and conjugated with PE/Cyanine7 under optimal conditions.
Concentration
Lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this product is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per 100,000 - million cells in a 100 µL volume of Annexin V Binding Buffer (Cat No. 422201). It is recommended that the reagent be titrated for optimal performance for each application.

Excitation Laser
Blue Laser (488 nm)
Green Laser (532 nm)/Yellow-Green Laser (561 nm)
Application Notes

Annexin V Staining

  1. Wash cells twice with cold BioLegend Cell Staining Buffer (Cat. No. 420201) and then resuspend cells in Annexin V Binding Buffer (Cat. No. 422201) at a concentration of 1x106 cells/mL.
  2. Transfer 100 µL of cell suspension in 5 mL test tube.
  3. Add 5 µL of fluorochrome conjugated Annexin V.
  4. Stain with a viability dye, such as PI (Cat. No. 421301), 7-AAD (Cat. Nos. 420403 & 420404), or Helix NP dyes (Cat. Nos. 425301, 425303, & 425305), if desired.
  5. Gently vortex the cells and incubate for 15 min at RT (25°C) in the dark.
  6. Add 400* µL of Annexin V Binding Buffer (Cat. No. 422201) to each tube. *For more concentrated samples, add a minimum of 200 µl of Annexin V Binding Buffer in this step.
  7. Analyze by flow cytometry.

For a better experience detecting apoptosis, we now recommend Apotracker™. Cell staining with Apotracker™ is Calcium independent. Thus, no special buffers are required, and the protocol can be shortened for single-step co-staining with other reagents.

Application References
  1. Koopman G, et al. 1994. Blood 84:1415.
  2. Vermes I, et al. 1995. J. Immunol. Methods 184:39.
  3. Dachary-Prigent J, et al. 1993. Blood 81:2554.
  4. Sekine C, et al. 2009. Int Immunol. PubMed
  5. Grujic M, et al. 2010. J. Immunol. 185:1730. PubMed
Product Citations
  1. Mo Y, et al. 2022. Front Immunol. 12:799896. PubMed
  2. Stirm K, et al. 2023. J Immunother Cancer. 11:. PubMed
  3. Lin YN, et al. 2022. Oncoimmunology. 11:2027136. PubMed
  4. Fernandes H, et al. 2022. Mol Ther Nucleic Acids. 28:307. PubMed
  5. Yang R, et al. 2022. J Adv Res. 35:259. PubMed
  6. Evgin L, et al. 2020. Nat Commun. 2.671527778. PubMed
  7. Si J, et al. 2020. Cancer Cell. 38(4):551-566.e11. PubMed
  8. Carlet M, et al. 2021. Nat Commun. 12:5655. PubMed
  9. Yoshinaga M, et al. 2022. Nat Commun. 13:6435. PubMed
  10. Carpio MA, et al. 2021. Cell Rep. 34:108827. PubMed
  11. Xu L, et al. 2022. Front Immunol. 13:841141. PubMed
RRID
AB_2721650 (BioLegend Cat. No. 640949)
not an antibody (BioLegend Cat. No. 640950)
not an antibody (BioLegend Cat. No. 640951)

Antigen Details

Biology Area
Apoptosis/Tumor Suppressors/Cell Death, Cell Biology, Neuroscience
Gene ID
308 View all products for this Gene ID
UniProt
View information about Annexin V on UniProt.org

Related FAQs

How is your Annexin made and what sequence does it cover?

It is made in E. coli, covering human aa Met1-Asp320.

How does pH and staining temperature affect Annexin V-Phosphatidylserine binding?

Annexin-Phosphatidylserine binding is lost below pH 5.2 and with prolonged incubation over a temperature of 42°C.

Why do I need to use Annexin V Binding Buffer?

Annexin V binding requires the presence of calcium in the solution.  So, we provide Annexin V Binding Buffer (cat # 422201), which is optimized for the best performance of Annexin V staining.

Can I use RPMI during Annexin V staining?

It is best to follow protocol as described on the product data sheet. Moreover, RPMI 1640 has a relatively high concentration of phosphate and low calcium ion concentration, which negatively impacts Annexin binding to its target phosphatidylserine (PS). Measurement of cell death by using Annexin V may also be significantly affected by time of incubation on ice, calcium concentration, and type of medium.

Can I freeze Annexin V conjugates?

It should not be frozen as it will lead to loss of biological activity due to dimerization.

Is Annexin V suitable for conjugation with the Maxpar® kit for CyTOF®?

Maxpar® Labeling kits require the protein to be partially reduced, so the metal chelate can be introduced through an SH group in the hinge region of the reduced antibody. Human Annexin V contains only one Cysteine which was reported to be chemically inactive. Thus, the Maxpar® labeling protocol would not work with Annexin V, unless a free –SH group can be introduced to Annexin V.  For more information regarding SH-mediated conjugation of Annexin V please consult published papers such as this one.

Go To Top Version: 5    Revision Date: 10/22/2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account