Purified anti-mouse CD45 Antibody

Pricing & Availability
Clone
I3/2.3 (See other available formats)
Regulatory Status
RUO
Other Names
T200, Ly-5, LCA
Isotype
Rat IgG2b, λ
Ave. Rating
Submit a Review
Product Citations
publications
I3.2.3_Purified_CD45_Antibody_FC_041714.jpg
C57BL/6 splenocytes were stained with purified CD45 (clone I3/2.3) (filled histogram) or purified rat IgG2b isotype control (open histogram), followed by anti-rat IgG FITC.
  • I3.2.3_Purified_CD45_Antibody_FC_041714.jpg
    C57BL/6 splenocytes were stained with purified CD45 (clone I3/2.3) (filled histogram) or purified rat IgG2b isotype control (open histogram), followed by anti-rat IgG FITC.
Compare all formats
Cat # Size Price Quantity Check Availability Save
147701 50 µg 44€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
147702 500 µg 175€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD45 is a 180-240 kD glycoprotein also known as the leukocyte common antigen (LCA), T200, or Ly-5. It is a member of the protein tyrosine phosphatase (PTP) family, expressed on all hematopoietic cells except mature erythrocytes and platelets. There are different isoforms of CD45 that arise from alternative splicing of exons 4, 5, and 6, which encode A, B, and C determinants, respectively. CD45 plays a key role in TCR and BCR signal transduction. These isoforms are very specific to the activation and maturation state of the cell as well as cell type. The primary ligands for CD45 are galectin-1, CD2, CD3, CD4, TCR, CD22, and Thy-1.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Mouse lymphoma cell line
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography.
Concentration
0.5 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C.
Application

FC - Quality tested
IHC-P, IHC-F - Reported in the literature, not verified in house
SB - Community verified

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.125 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Application Notes

Additional reported applications (for the relevant formats) include: immunohistochemical staining of paraffin embedded sections1 and frozen tissue sections2.

Additional Product Notes

This product has been verified for IHC-F (Immunohistochemistry - frozen tissue sections) on the NanoString GeoMx® Digital Spatial Profiler. The GeoMx® enables researchers to perform spatial analysis of protein and RNA targets in FFPE and fresh frozen human and mouse samples. For more information about our spatial biology products and the GeoMx® platform, please visit our spatial biology page.

Application References
  1. Kliment C, et al. 2009. J. Mol. Cell Cardiol. 47:730. (IHC)
  2. Reynolds JM, et al. 2007. J. Immunol. 179:313. (IHC)
Product Citations
  1. Pilling D, et al. 2022. Exp Lung Res. 291:48. PubMed
  2. Pilling D, et al. 2022. Respir Res. 23:215. PubMed
  3. Carpenter SM, et al. 2017. PLoS Pathog. 13:e1006704. PubMed
  4. Zhao L, et al. 2018. Nat Med. 24:1536. PubMed
  5. Zhang Z, et al. 2018. Nat Med. 24:617. PubMed
  6. Liu J, et al. 2022. Stem Cell Res Ther. 13:247. PubMed
RRID
AB_2563416 (BioLegend Cat. No. 147701)
AB_2563416 (BioLegend Cat. No. 147702)

Antigen Details

Structure
Protein tyrosine phosphatase (PTP) family, 180-240 kD
Distribution

All hematopoietic cells except mature erythrocytes and platelets

Function
Phosphatase, T and B cell activation
Ligand/Receptor
Galectin-1, CD2, CD3, CD4, TCR, CD22, Thy-1
Cell Type
B cells, Mesenchymal Stem Cells
Biology Area
Cell Biology, Immunology, Inhibitory Molecules, Neuroscience, Neuroscience Cell Markers, Stem Cells
Molecular Family
CD Molecules, TCRs
Antigen References

1. Barclay A, et al. 1997. The Leukocyte Antigen FactsBook Academic Press.
2. Trowbridge IS and Thomas ML. 1994. Annu. Rev. Immunol. 12:85. 
3. Kishihara K, et al. 1993. Cell 74:143.
4. Pulido R, et al. 1988. J. Immunol. 140:3851.

Gene ID
19264 View all products for this Gene ID
UniProt
View information about CD45 on UniProt.org

Related FAQs

If an antibody clone has been previously successfully used in IBEX in one fluorescent format, will other antibody formats work as well?

It’s likely that other fluorophore conjugates to the same antibody clone will also be compatible with IBEX using the same sample fixation procedure. Ultimately a directly conjugated antibody’s utility in fluorescent imaging and IBEX may be specific to the sample and microscope being used in the experiment. Some antibody clone conjugates may perform better than others due to performance differences in non-specific binding, fluorophore brightness, and other biochemical properties unique to that conjugate.

Will antibodies my lab is already using for fluorescent or chromogenic IHC work in IBEX?

Fundamentally, IBEX as a technique that works much in the same way as single antibody panels or single marker IF/IHC. If you’re already successfully using an antibody clone on a sample of interest, it is likely that clone will have utility in IBEX. It is expected some optimization and testing of different antibody fluorophore conjugates will be required to find a suitable format; however, legacy microscopy techniques like chromogenic IHC on fixed or frozen tissue is an excellent place to start looking for useful antibodies.

Are other fluorophores compatible with IBEX?

Over 18 fluorescent formats have been screened for use in IBEX, however, it is likely that other fluorophores are able to be rapidly bleached in IBEX. If a fluorophore format is already suitable for your imaging platform it can be tested for compatibility in IBEX.

The same antibody works in one tissue type but not another. What is happening?

Differences in tissue properties may impact both the ability of an antibody to bind its target specifically and impact the ability of a specific fluorophore conjugate to overcome the background fluorescent signal in a given tissue. Secondary stains, as well as testing multiple fluorescent conjugates of the same clone, may help to troubleshoot challenging targets or tissues. Using a reference control tissue may also give confidence in the specificity of your staining.

How can I be sure the staining I’m seeing in my tissue is real?

In general, best practices for validating an antibody in traditional chromogenic or fluorescent IHC are applicable to IBEX. Please reference the Nature Methods review on antibody based multiplexed imaging for resources on validating antibodies for IBEX.

Go To Top Version: 3    Revision Date: 01/24/2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account