APC anti-human CD62L

Pricing & Availability

Analyte Specific Reagent. Analytical and performance characteristics are not established.

Clone
DREG-56
Other Names
L-selectin, LECAM-1, LAM-1, Leu-8, TQ-1
Isotype
Mouse IgG1, κ
DREG-56_APC_CD62L_ASR_092823
Typical result from human peripheral lymphocytes stained either with DREG-56 APC used at 5 μL/test (filled histogram) or with an isotype control (open histogram).
  • DREG-56_APC_CD62L_ASR_092823
    Typical result from human peripheral lymphocytes stained either with DREG-56 APC used at 5 μL/test (filled histogram) or with an isotype control (open histogram).
Compare all formats See APC spectral data
Cat # Size Price Quantity Check Availability
980706 500 µL $370.00
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD62L is a 74-95 kD single chain type I glycoprotein referred to as L-selectin or LECAM-1. It is expressed on most peripheral blood B cells, subsets of T and NK cells, monocytes, granulocytes, and certain hematopoietic malignant cells. CD62L binds to carbohydrates present on certain glycoforms of CD34, glycam-1, and MAdCAM-1 and with a low affinity to anionic oligosaccharide sequences related to sialylated Lewis X (sLex, CD15s) through its C-type lectin domain. CD62L is important for the homing of naïve lymphocytes to high endothelial venules in peripheral lymph nodes and Peyer's patches. It also plays a role in leukocyte rolling on activated endothelial cells.

Technical data sheet

Product Details

Reactivity
Human
Formulation
Phosphate-buffered solution, pH 7.2, 0.09% sodium azide, 0.2% (w/v) BSA (origin USA), and a stabilizer.
Preparation
The antibody was purified by affinity chromatography, and conjugated with APC under optimal conditions.
Concentration
25 µg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

Suggested for Flow Cytometry

Disclaimer

WARNINGS AND PRECAUTIONS

  1. Use appropriate personal protective equipment and safety practices per universal precautions when working with this reagent. Refer to the reagent safety data sheet.
  2. This antibody contains sodium azide. Follow federal, state and local regulations to dispose of this reagent. Sodium azide build-up in metal wastepipes may lead to explosive conditions; if disposing of reagent down wastepipes, flush with water after disposal.
  3. All specimens, samples and any material coming in contact with them should be considered potentially infectious and should be disposed of with proper precautions and in accordance with federal, state and local regulations.
  4. Do not use this reagent beyond the expiration date stated on the label.
  5. Do not use this reagent if it appears cloudy or if there is any change in the appearance of the reagent as these may be an indication of possible deterioration.
  6. Avoid prolonged exposure of the reagent or stained cells to light.

Antigen Details

Antigen References
  1. Kishimoto T, et al. 1990. P. Natl. Acad. Sci. USA. 87:2244.
  2. Kishimoto T, et al. 1991. Blood. 78:805-11.
Go To Top Version: 1    Revision Date: 11/01/2023

Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses.

 

BioLegend Inc., 8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.