Pricing & Availability
Technical data sheet
- Regulatory Status
- RUO
- Other Names
- Granulocyte colony stimulating factor, CSF-3, CSFG, MGI-IG
Cat # | Size | Price | Quantity Check Availability | ||
---|---|---|---|---|---|
441704 | 5 plates | $360.00 |
Description
Mouse Granulocyte-Colony Stimulating Factor (G-CSF), also known as mouse CSF-3, is a growth factor and pleiotropic cytokine that influences cells from the bone marrow to differentiate, proliferate and activate the neutrophilic granulocyte lineage (Neutrophils). Mouse G-CSF is produced primarily by monocytes and macrophages upon activation and is measured and tested for differentiation studies. Mouse G-CSF belongs to the IL-6 superfamily and is a polypeptide chain containing 179 amino acids and has a molecular weight of 19 kD. It is naturally produced by the body and is also available as an injection. Human and mouse G-CSF proteins share 76% sequence identity at the amino acid level.
Kit Contents
- Kit Contents
-
- Mouse G-CSF Capture Antibody (200X)
- Mouse G-CSF Detection Antibody (200X)
- Mouse G-CSF Standard
- Avidin-HRP (1000X)
- Substrate Solution F
- Coating Buffer B (5X)
- Assay Diluent B (5X)
- Blocking Buffer A (2X)
Product Details
- Verified Reactivity
- Mouse
- Application
-
ELISA
- As a part of BioLegend's efforts to go green, each new lot of the ELISA MAX™ sets will include a summarized version of its manual. Click here for more information.
- Sensitivity
- 3.8 - 8.6 pg/mL
- Standard Range
- 12.5 - 800 pg/mL
- Materials Not Included
-
- Microwell plates: BioLegend Cat. No. 423501 is recommended
- Wash Buffer: BioLegend Cat. No. 421601 is recommended, or PBS + 0.05% Tween-20
- Stop Solution: BioLegend Cat. No. 423001 is recommended, or acid solution, e.g. 2N H2SO4
- Plate Sealers: BioLegend Cat. No. 423601 is recommended
- PBS (Phosphate-Buffered Saline): 8.0 g NaCl, 1.16 g Na2HPO4, 0.2 g KH2PO4, 0.2 g KCl, add deionized water to 1 L; pH to 7.4, 0.2 μm filtered
- Deionized (DI) water
- A microplate reader capable of measuring absorbance at 450 nm
- Adjustable pipettes to measure volumes ranging from 2 μL to 1 mL
- Wash bottle or automated microplate washer
- Log-Log graph paper or software for data analysis
- Tubes to prepare standard dilutions
- Timer
Antigen Details
- Cell Type
- Embryonic Stem Cells, Hematopoietic stem and progenitors
- Biology Area
- Immunology, Stem Cells
- Molecular Family
- Cytokines/Chemokines, Growth Factors
- Gene ID
- NA
- UniProt
- View information about G-CSF on UniProt.org