PE/Fire™ 810 Streptavidin

Pricing & Availability
Regulatory Status
RUO
Other Names
Streptavidin- PE/Fire™, SAv- PE/Fire™ 810, streptavidin PE/Fire™ 810
Streptavidin_PEFire810_Antibody_060823
Human peripheral blood lymphocytes were stained with biotinylated anti-human CD3, followed by SAV-PE/Fire™ 810 (filled histogram), or biotinylated mouse IgG1, κ isotype control, followed with SAV-PE/Fire™ 810 (open histogram).
  • Streptavidin_PEFire810_Antibody_060823
    Human peripheral blood lymphocytes were stained with biotinylated anti-human CD3, followed by SAV-PE/Fire™ 810 (filled histogram), or biotinylated mouse IgG1, κ isotype control, followed with SAV-PE/Fire™ 810 (open histogram).
  • Streptavidin_PEFire810_Antibody_2_060823
    Human peripheral blood lymphocytes were stained with anti-human CD8 FITC and biotinylated anti-human CD3 (left) or biotinylated mouse IgG1, κ isotype control (right), followed with SAV-PE/Fire™ 810.
See PE/Fire™ 810 spectral data
Cat # Size Price Quantity Check Availability
405367 25 µg $171.00
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Streptavidin is a 52.8 kDa tetrameric protein obtained from Streptomyces avidinii. It binds to biotin with a very high affinity and is one of the strongest interactions in nature with a dissociation constant of 10-14 mol/L. It is used to detect biotinylated proteins in a wide range of applications.

Technical data sheet

Product Details

Verified Reactivity
Human, Mouse, Rat, All Species
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
Streptavidin is conjugated with PE/Fire™ 810 under optimal conditions.
Concentration
0.2 mg/mL (concentration relates to the Streptavidin only component of the conjugate)
Storage & Handling
The Streptavidin PE/Fire™ 810 solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

This streptavidin product is quality control tested by immunofluorescent staining with flow cytometric analysis. The concentration provided is based upon molecular mass of streptavidin independent of any additional molecular mass that might be added by the PE/Fire™ 810 conjugation. For flow cytometric staining, the suggested use of this reagent is ≤ 0.125 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application.

* PE/Fire™ 810 has a maximum excitation of 488/561 nm and a maximum emission of 810 nm.


Excessive exposure to light, and commonly used fixation, permeabilization buffers can affect PE/Fire™ 810 fluorescence signal intensity and spread. Please keep conjugates protected from light exposure. For more information and representative data, visit our Fire Dyes page.
Excitation Laser
Blue Laser (488 nm)
Green Laser (532 nm)/Yellow-Green Laser (561 nm)
Go To Top Version: 1    Revision Date: 06/08/2023

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

Login/Register
Forgot your password? Reset Password
Request an Account