Tandem Stabilizer

Pricing & Availability
Regulatory Status
RUO
A_Tandem_Stabilizer_Solution_062322
Human peripheral blood lymphocytes stained with anti-human CD4 (clone SK3) APC/Cyanine7 followed by 1 hour fixation with FluroFix Buffer. The last wash step was done using 1X Tandem Stabilizer working solution in Cell Staining Buffer, centrifuged, supernatant discarded, then resuspended in 500 µL of 1X Tandem Stabilizer. Cells were either acquired on a cytometer on the same day (Day 0) or stored for indicated times before being acquired. Resulting of the cell treatment and/or storage time the APC/Cyanine7 tandem dye degraded (as evidenced by the shift of the APC/Cyanine7 into APC) when the cells were left only in Cell Staining buffer; however, the addition of Tandem Stabilizer to the Cell Staining buffer prevented such degradation.
  • A_Tandem_Stabilizer_Solution_062322
    Human peripheral blood lymphocytes stained with anti-human CD4 (clone SK3) APC/Cyanine7 followed by 1 hour fixation with FluroFix Buffer. The last wash step was done using 1X Tandem Stabilizer working solution in Cell Staining Buffer, centrifuged, supernatant discarded, then resuspended in 500 µL of 1X Tandem Stabilizer. Cells were either acquired on a cytometer on the same day (Day 0) or stored for indicated times before being acquired. Resulting of the cell treatment and/or storage time the APC/Cyanine7 tandem dye degraded (as evidenced by the shift of the APC/Cyanine7 into APC) when the cells were left only in Cell Staining buffer; however, the addition of Tandem Stabilizer to the Cell Staining buffer prevented such degradation.
  • B_Tandem_Stabilizer_Solution_062322
    Human peripheral blood lymphocytes stained with anti-human CD4 (clone SK3) APC/Cyanine7 followed by fix/perm using Fixation (BioLegend Cat. No. 420801) and Permeabilization Wash (BioLegend Cat. No. 421002) Buffer following recommended protocol for intracellular cytokine staining. The last wash step was done using 1X Tandem Stabilizer working solution in Cell Staining Buffer, centrifuged, supernatant discarded, then resuspended in 500 µL of 1X Tandem Stabilizer. Cells were either acquired on a cytometer on the same day (Day 0) or stored for indicated times before being acquired. Resulting of the cell treatment and/or storage time the APC/Cyanine7 tandem dye degraded (as evidenced by the shift of the APC/Cyanine7 into APC) when the cells were left only in Cell Staining buffer; however, the addition of Tandem Stabilizer to the Cell Staining buffer prevented such degradation.
  • C_Tandem_Stabilizer_Solution_062322
    Human peripheral blood lymphocytes stained with anti-human CD4 (clone SK3) APC/Cyanine7 followed by fix/perm with True-Nuclear™ Transcription Factor Buffer Set following recommended protocol. The last wash step was done using 1X Tandem Stabilizer working solution in Cell Staining Buffer, centrifuged, supernatant discarded, then resuspended in 500 µL of 1X Tandem Stabilizer. Cells were either acquired on a cytometer on the same day (Day 0) or stored for indicated times before being acquired. Resulting of the cell treatment and/or storage time the APC/Cyanine7 tandem dye degraded (as evidenced by the shift of the APC/Cyanine7 into APC) when the cells were left only in Cell Staining buffer; however, the addition of Tandem Stabilizer to the Cell Staining buffer prevented such degradation.
Cat # Size Price Quantity Check Availability
421802 1 vial $112.00
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description
Tandem Stabilizer helps to reduce tandem dye de-coupling when added as a supplement to buffers commonly used to store stained, fixed cells, as well as those used for fixation and permeabilization procedures. 
Technical data sheet

Product Details

Storage & Handling
This product is shipped as a dry powder, and requires reconstitution with distilled water prior to use. Store the vial of dry Tandem Stabilizer at room temperature or lower, in a dry place, protected from light. Keep the vial tightly closed. Reconstituted 1000X Tandem Stabilizer can be stored at 4°C protected from light for up to 1 month, or at -20°C for up to 3 months.
Application Notes
To use, dissolve the contents of the vial with 500 µL of deionized water to make a 1000X stock solution. The stock solution can be stored at 4°C protected from light for up to 1 month. Make a 1X Tandem Stabilizer working solution by diluting the 1000X stock solution into the desired buffer (e.g. Cell Staining Buffer: BioLegend Cat. No. 420201). Mix contents well by inverting several times. Buffers supplemented with Tandem Stabilizer can be used and handled in the same manner as the original buffers (without additive) in their corresponding protocols. 
 
Storage of stained, fixed cells in cell staining buffer containing Tandem Stabilizer
  • Prepare a 1X working solution with Cell Staining Buffer (BioLegend Cat. No. 420201, or equivalent) from the 1000X stock solution referred to above. 
  • Use this 1X Tandem Stabilizer working solution to perform the last wash step post-cell staining. 
  • After centrifugation and discarding wash supernatant, resuspend the pellet in adequate volume of 1X Tandem Stabilizer working solution (i.e. 500 µL in 5 mL FACS tubes); 
  • Store the samples at 4°C protected from light, for no more than 4 days prior to sample acquisition and analysis.


Note: Overall effectiveness in preventing tandem dye de-coupling using Tandem Stabilizer-supplemented buffers may vary. Users should test the compatibility of the Tandem Stabilizer with the buffers in which to use them in, and determine the effectiveness of the protection and the storage time.

Antigen Details

Gene ID
NA
Go To Top Version: 2    Revision Date: 11/21/2022

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

Login/Register
Forgot your password? Reset Password
Request an Account