APC anti-phycoerythrin (PE) Antibody

Pricing & Availability
Clone
PE001 (See other available formats)
Regulatory Status
RUO
Other Names
PE
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
PE001_APC_Phycoerythrin_Antibody_080819.png
C57BL/6 thymocytes stained with CD4 PE and anti-phycoerythrin (left) APC or mouse IgG1, κ isotype control (right) APC.
  • PE001_APC_Phycoerythrin_Antibody_080819.png
    C57BL/6 thymocytes stained with CD4 PE and anti-phycoerythrin (left) APC or mouse IgG1, κ isotype control (right) APC.
Compare all formats See APC spectral data
Cat # Size Price Quantity Check Availability Save
408107 25 µg 63€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
408108 100 µg 167€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

The PE001 antibody reacts with both phycoerythrin (PE) alone and PE conjugated with antibody or streptavidin, as well as PE tandem dyes such as PE/Cyanine5, PE/Cyanine5.5 and PE/Cyanine7. When PE001 antibody is used in a three-step staining procedure or separation of PE-antibody labeled cells, it does not quench PE fluorescence or react with tested mouse and human cells. The PE001 antibody can be used for separation of PE-antibody labeled cells or as a secondary step to amplify PE conjugated primary antibody signals (i.e. biotinylated PE001 as secondary step, followed by Streptavidin-PE).

Product Details
Technical Data Sheet (pdf)

Product Details

Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Phycoerythrin
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography and conjugated with APC under optimal conditions.
Concentration
0.2 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.5 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Excitation Laser
Red Laser (633 nm)
Application References
  1. Taylor RT, et al. 2007. J. Immunol. 178:5659.
Product Citations
  1. Greenshields-Watson A, et al. 2020. Cell Rep. 32:107885. PubMed
RRID
AB_2814387 (BioLegend Cat. No. 408107)
AB_2814387 (BioLegend Cat. No. 408108)

Related FAQs

What type of PE do you use in your conjugates?
We use R-PE in our conjugates.
Go To Top Version: 2    Revision Date: 09.16.2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account