GMP FITC anti-human CD64 Antibody

Pricing & Availability
Clone
10.1 (See other available formats)
Workshop
VI MA36
Other Names
FcγRI, FcR I
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
10dot1_GMP-FITC_CD64_Antibody_100121.png
Typical results from human peripheral blood monocytes stained either with 10.1 FITC used at 5 µL/test (solid histogram) or with an isotype control (dashed histogram).
  • 10dot1_GMP-FITC_CD64_Antibody_100121.png
    Typical results from human peripheral blood monocytes stained either with 10.1 FITC used at 5 µL/test (solid histogram) or with an isotype control (dashed histogram).
Compare all formats See GMP FITC spectral data
Cat # Size Price Quantity Check Availability Save
260014 100 tests 188€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD64 is a 72 kD single chain type I glycoprotein also known as FcγRI and FcR I. CD64 is a member of the immunoglobulin superfamily and is expressed on monocytes/macrophages, dendritic cells, and activated granulocytes. The expression can be upregulated by IFN-γ stimulation. CD64 binds IgG immune complex. It plays a role in antigen capture, phagocytosis of IgG/antigen complexes, and antibody-dependent cellular cytotoxicity (ADCC).

Product Details
Quality Statement This BioLegend’s GMP-RUO reagent is a fluorochrome-labeled monoclonal antibody single reagent for Research Use Only. Suitable for use in laboratory-developed multicolor flow cytometry tests. Single GMP-RUO products can be used in various multicolor flow cytometry combinations. Laboratory need to establish the GMP-RUO performance characteristics in combination with other reagents in normal and pathological samples.
Technical Data Sheet (pdf)

Product Details

Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Human rheumatoid synovial fluid cells and fibronectin-purified monocytes.
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide, 0.2% (w/v) BSA (origin USA) and a stabilizer.
Preparation
The antibody was purified by affinity chromatography and conjugated with FITC under optimal conditions.
Concentration
200 µg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

Excitation Laser
Blue Laser (488 nm)
Application Notes

Clone 10.1 recognizes the EC3 epitope of CD64. While both contain the EC3 domain, in-house testing suggests that clone 10.1 preferentially binds to CD64A (FcγRIA), but not CD64B (FcγRIB). Additional reported applications (for the relevant formats) include: blocking of human IgG3 and murine IgG2a binding to FcγRI2,5,6,11 and immunohistochemical staining of acetone-fixed frozen tissue sections12.

Application References
  1. McMichael A, et al. Eds. 1987. Leucocyte Typing III. Oxford University Press. New York.
  2. Schlossman S, et al. Eds. 1995. Leucocyte Typing V. Oxford University Press. New York. p. 874.
  3. Kishimoto T, et al. Eds. 1997. Leucocyte Typing VI. Garland Publishing Inc. London.
  4. Holl V, et al. 2004. J. Immunol. 173:6274.
  5. Hober D, et al. 2002. J. Gen. Virol. 83:2169.
  6. Cho HJ, et al. 2007. Physiol Genomics 149:60.
  7. van Tits L, et al. 2005. Arterioscler Thromb Vasc Biol. 25:717. PubMed
  8. Bruhns P, et al. 2008. Blood 113:3716. PubMed
  9. Yoshino N, et al. 2000. Exp. Anim. (Tokyo) 49:97. (FC)
  10. Carter DL, et al. 1999. Cytometry 37:41. (FC)
  11. Dougherty GJ, et al. 1987. Eur. J. Immunol. 17:1453.
  12. Blom AB, et al. 2003. Arthritis Rheum. 48(4):1002-14. (IHC)
Disclaimer

GMP RUO Flow Cytometry Antibodies. BioLegend GMP RUO fluorophore conjugated antibodies are manufactured in a dedicated GMP facility and compliant with ISO 13485:2016. For research use only. Not for use in diagnostic or therapeutic procedures. Our processes include:

  • Batch-to-batch consistency
  • Material traceability
  • Documented procedures
  • Documented employee training
  • Equipment maintenance and monitoring records
  • Lot-specific certificates of analysis
  • Quality audits per ISO 13485:2016
  • QA review of released products

Antigen Details

Structure
Ig superfamily, type I glycoprotein, 72 kD
Distribution

Monocytes, macrophages, dendritic cells, activated granulocytes

Function
Phagocytosis, ADCC
Ligand/Receptor
IgG receptor
Cell Type
Dendritic cells, Granulocytes, Macrophages, Monocytes
Biology Area
Immunology, Innate Immunity
Molecular Family
CD Molecules, Fc Receptors
Antigen References

1. Hulett M, et al. 1994. Adv. Immunol. 57:1.
2. van de Winkel J, et al. 1993. Immunol. Today 14:215.

Gene ID
2209 View all products for this Gene ID
UniProt
View information about CD64 on UniProt.org

Related FAQs

Is our human Trustain FcX™ (cat# 422302) compatible with anti human CD16, CD32 and CD64 clones 3G8, FUN-2 and 10.1 respectively?

Yes

Other Formats

View All CD64 Reagents Request Custom Conjugation
Description Clone Applications
Biotin anti-human CD64 10.1 FC
FITC anti-human CD64 10.1 FC
PE anti-human CD64 10.1 FC
Purified anti-human CD64 10.1 FC,IHC-F,Block
Alexa Fluor® 488 anti-human CD64 10.1 FC
Alexa Fluor® 647 anti-human CD64 10.1 FC
APC anti-human CD64 10.1 FC
Pacific Blue™ anti-human CD64 10.1 FC
Brilliant Violet 421™ anti-human CD64 10.1 FC
PE/Cyanine7 anti-human CD64 10.1 FC
PerCP/Cyanine5.5 anti-human CD64 10.1 FC
APC/Cyanine7 anti-human CD64 10.1 FC
Brilliant Violet 510™ anti-human CD64 10.1 FC
Purified anti-human CD64 (Maxpar® Ready) 10.1 FC,CyTOF®
PE/Dazzle™ 594 anti-human CD64 10.1 FC
Brilliant Violet 605™ anti-human CD64 10.1 FC
APC/Fire™ 750 anti-human CD64 10.1 FC
PE anti-human CD64 10.1 FC
PE/Dazzle™ 594 anti-human CD64 10.1 FC
FITC anti-human CD64 10.1 FC
TotalSeq™-A0162 anti-human CD64 10.1 PG
Brilliant Violet 711™ anti-human CD64 10.1 FC
Alexa Fluor® 700 anti-human CD64 10.1 FC
Brilliant Violet 785™ anti-human CD64 10.1 FC
TotalSeq™-C0162 anti-human CD64 10.1 PG
Ultra-LEAF™ Purified anti-human CD64 10.1 FC,IHC-F,Block
TotalSeq™-B0162 anti-human CD64 10.1 PG
TotalSeq™-D0162 anti-human CD64 10.1 PG
GMP PE anti-human CD64 10.1 FC
GMP FITC anti-human CD64 10.1 FC
Brilliant Violet 650™ anti-human CD64 10.1 FC
GMP PE/Dazzle™ 594 anti-human CD64 10.1 FC
PE/Cyanine7 anti-human CD64 10.1 FC
APC/Fire™ 750 anti-human CD64 10.1 FC
PerCP/Cyanine5.5 anti-human CD64 10.1 FC
Pacific Blue™ anti-human CD64 10.1 FC
GMP APC/Fire™ 750 anti-human CD64 10.1 FC
GMP PE/Cyanine7 anti-human CD64 10.1 FC
Go To Top Version: 1    Revision Date: 11.04.2021

For Research Use Only. Suitable for ex vivo cell processing. Not for injection or diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account