LEGEND MAX™ Human Total IgG ELISA Kit

Pricing & Availability
Regulatory Status
RUO
Other Names
IgG, Immunoglobulin G, IgG1, IgG2, IgG3, IgG4
Ave. Rating
Submit a Review
Product Citations
publications
LEGEND-MAX_Human-Total-IgG-ELISA-kit_030824
  • LEGEND-MAX_Human-Total-IgG-ELISA-kit_030824
Cat # Size Price Quantity Check Availability Save
432307 1 Pre-coated Plate 436€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

IgG is a monomeric immunoglobulin composed of two identical heavy chains and two identical light chains linked together by inter-chain disulfide bonds. There are four IgG subclasses (IgG1, IgG2, IgG3, and IgG4) in humans named in order of decreasing abundance. They differ in the size of the hinge region and the number and arrangements of the interchain disulfide bonds linking their heavy chains. Of the 5 immunoglobulin isotypes, IgG is most abundant in human serum. IgG is synthesized and secreted by plasma B cells and is involved in the secondary immune response. The measurement of IgG can be a diagnostic tool for certain conditions such as autoimmune diseases, gastrointestinal conditions or immunoglobulin-deficiency disorders. 

The BioLegend LEGEND MAX™ Human Total IgG ELISA Kit is a Sandwich Enzyme- Linked Immunosorbent Assay (ELISA) with a 96-well strip plate that is pre-coated with a human monoclonal anti-human IgG antibody. The detection antibody is a biotinylated anti-human IgG antibody. This kit is specifically designed for the accurate quantitation of human IgG in serum, plasma, breast milk, saliva and urine. This kit is analytically validated with ready-to-use reagents.

Product Details
Technical Data Sheet (pdf)

Kit Contents

Kit Contents
  • Human Total IgG Pre-coated 96-well Strip Microplate 
  • Human Total IgG Detection Antibody 
  • Human Total IgG Lyophilized Standard
  • Avidin HRP
  • Assay Buffer B
  • Substrate Solution D
  • Wash Buffer (20X)
  • Stop Solution
  • Plate Sealers

Product Details

Verified Reactivity
Human
Application

ELISA

Sensitivity
0.12 ± 0.03 ng/mL
Standard Range
0.625 – 40 ng/mL
Materials Not Included
  • Microplate reader able to measure absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 1 µL to 1,000 µL
  • Deionized water
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Plate Shaker
  • Polypropylene vials

Antigen Details

Cell Type
B cells
Biology Area
Adaptive Immunity, Immunology
Gene ID
NA
UniProt
View information about IgG on UniProt.org

Related FAQs

In your LEGEND MAX™ ELISA Kits, there is a step that calls for washing the plates before adding sample. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The additional washing step is designed to remove these components before you start the assay. If you do not perform the washing, the effect on assay performance is negligible.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The wash buffer provided in all our LEGEND MAX™ kits is the same and the part numbers on the wash buffer bottles in these kits should be identical. For ELISA MAX™ Deluxe and ELISA MAX™ Standard Sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

In some cases, dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

Go To Top Version: 1    Revision Date: 03.08.2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account