MojoSort™ Human CD56 Nanobeads

Pricing & Availability
Regulatory Status
RUO
Ave. Rating
Submit a Review
Product Citations
publications
MojoSort_-Human_CD56_Nanobeads_1_042921.png
A single cell suspension from human PBMCs was prepared for the positive selection of CD56+ cells using the MojoSort™ Human CD56 Nanobeads. The cells were incubated with True-Stain Monocyte Blocker™ prior to the addition of the Human CD56 Nanobeads. After separation, the cells were stained with anti-human CD56 (NCAM) (clones 5.1H11 and HCD56) PE and anti-human CD3 (clone UCHT1) APC. Dead cells were excluded by Helix NP™ Blue. Purity of the CD56+ cells ranges between 80-90% due to donor variation.
  • MojoSort_-Human_CD56_Nanobeads_1_042921.png
    A single cell suspension from human PBMCs was prepared for the positive selection of CD56+ cells using the MojoSort™ Human CD56 Nanobeads. The cells were incubated with True-Stain Monocyte Blocker™ prior to the addition of the Human CD56 Nanobeads. After separation, the cells were stained with anti-human CD56 (NCAM) (clones 5.1H11 and HCD56) PE and anti-human CD3 (clone UCHT1) APC. Dead cells were excluded by Helix NP™ Blue. Purity of the CD56+ cells ranges between 80-90% due to donor variation.
  • MojoSort_-Human_CD56_Nanobeads_2_042921.png
    A single cell suspension from human PBMCs was prepared for the positive selection of CD56+ cells using the MojoSort™ Human CD56 Nanobeads. The cells were incubated with True-Stain Monocyte Blocker™ prior to the addition of the Human CD56 Nanobeads. After separation, the cells were stained with anti-human CD56 (NCAM) (clones 5.1H11 and HCD56) PE and anti-human CD335 (NKp46) (clone 9E2) APC. Dead cells were excluded by Helix NP™ Blue.
Cat # Size Price Quantity Check Availability Save
480155 10 tests 239€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
480156 100 tests 698€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Human CD56+ cells are either selected or depleted by incubating the sample with the directly conjugated CD56 Nanobeads. The magnetically labeled fraction is retained by the use of a magnetic separator. After collection of the CD56+ cells, downstream applications include functional assays, gene expression, phenotypic characterization, etc.

MojoSort™ reagents are also compatible with column-based cell separation systems available from other vendors. Optimized protocols for cell separation using columns from in-house testing are provided for each kit under the “Related Protocols” section, as well as representative data on the product webpage (where available). Data generated using column separators are indicated on the figure legend.

Due to the property of the beads, MojoSort™ reagents typically require dilution for optimal use on column separators. Where available, recommended dilution factors for each kit component based on in-house testing are provided under the “Application Notes” section of the webpage.

Product Details
Technical Data Sheet (pdf)

Kit Contents

Kit Contents

For Cat. No. 480155:
•  1 vial containing 200 μL of True-Stain Monocyte Blocker™
•  1 vial containing 100 µL of Human CD56 Nanobeads

For Cat. No. 480156:
•  2 vials containing 1 mL of True-Stain Monocyte Blocker™
•  1 vial containing 1 mL of Human CD56 Nanobead

Product Details

Verified Reactivity
Human
Formulation
Particle: Aqueous solution containing 0.05% sodium azide and 0.3% BSA.
Preparation
Conjugated nanobeads: Protein-coated magnetic beads.
Storage & Handling
All components should be stored undiluted between 2°C and 8°C
Application

Cell Separation (MojoSort™) - Quality tested

Recommended Usage

20 µL of True-Stain Monocyte Blocker™ for 1 x 107 cells in 100 µL of buffer.

10 µL of Human CD56 Nanobeads for 1 x 107 cells in 100 µL of buffer

Application Notes

This kit is designed for the positive selection or depletion of human CD56+ cells from PBMCs. 

Each lot has been individually optimized. Do not mix and match components from different lots or different kits.

Nanobead dilution to use in column: 5x

Related FAQs

Is there a way to detach your magnetic particles from the cell surface?

MojoSort™ Nanobeads: These magnetic particles cannot be removed from cells. This includes standalone Nanobeads and MojoSort kits using Nanobeads. We have found that cells are functional without the need to detach the magnetic Nanobeads.

 

MojoSort Microbeads: These magnetic particles may be released following the detailed product-specific protocol.

What is the size of your magnetic particles?

MojoSort Nanobeads: the average diameter is approximately 130 nm.

 

MojoSort Microbeads: the average diameter is approximately 1 μm.

Are MojoSort™ Nanobeads compatible with other commercially available magnetic separation systems?

MojoSort™ magnetic particles can be used with other commercially available magnetic separators, both free standing magnets and column-based systems. Because MojoSort™ protocols are optimized for the MojoSort™ separator, the protocols may need to be adjusted for other systems.  Please contact BioLegend Technical Service for more product-specific information and guidance. We do not recommend using MojoSort™ particles for BD’s IMag™ or Life Technologies’ DynaMag™.

What antibodies are present in the depletion cocktails provided for isolation kits?

Please contact our technical service team for further assistance.

Go To Top Version: 1    Revision Date: 04.29.2021

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account