Purified anti-mouse H-2Kd Antibody

Pricing & Availability
Clone
SF1-1.1 (See other available formats)
Regulatory Status
RUO
Other Names
MHC class I
Isotype
Mouse (SJL) IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
SF1-1dot1_Pure_A_020708
Balb/c mouse splenocytes stained with purified SF1-1.1, followed by anti-mouse IgG2a FITC
  • SF1-1dot1_Pure_A_020708
    Balb/c mouse splenocytes stained with purified SF1-1.1, followed by anti-mouse IgG2a FITC
  • SF1-1dot1_Pure_B_020708
    Balb/c mouse splenocytes stained with purified SF1-1.1, followed by anti-mouse IgG2a FITC
Compare all formats
Cat # Size Price Quantity Check Availability Save
116601 50 µg 62€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

The SF1-1.1 antibody reacts with the H-2Kd MHC class I alloantigens expressed on nucleated cells from mice of the H-2Kd haplotype. H-2Kd is involved in antigen presentation to T cells expressing CD3/TCR and CD8 proteins.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
BALB/c Mouse cells
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography.
Concentration
0.5 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C.
Application

FC - Quality tested
IP, WB - Reported in the literature, not verified in house

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤0.25 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Application Notes

The SF1-1.1 antibody is weakly cross-reactive with H-2k but does not cross-react with other haplotypes (b, j, p, q, s, v). Clone SF1-1.1 recognizes the a3 domain of Kd.

Additional reported applications (for the relevant formats) include: immunoprecipitation1,4 and Western blotting2.

Application References
  1. Noun G, et al. 1996. J. Immunol. 157:2455. (IP)
  2. Abastado JP, et al. 1993. J. Immunol. 151:3569. (WB)
  3. Bashuda H, et al. 1997. Transplantation 63:113.
  4. Sester M, et al. 2000. J. Biol. Chem. 34:113. (IP)
  5. Ma XT, et al. 2006. Cancer Res. 66:1169. (FC)
  6. Norian LA and Allen PM. 2004. J. Immunol. 173:835. (FC)
  7. Norian L, et al. 2004. J. Immunol.. 173:835. PubMed
  8. Delon J, et al. 1998. Immunity 9:467.
Product Citations
  1. Cai S, et al. 2020. Sci Rep. 10:14249. PubMed
  2. Robert S, et al. 2018. Bone Marrow Transplant. 53:807. PubMed
  3. Borges TJ, et al. 2018. Nat Commun. 9:3482. PubMed
  4. Echeverria GV, et al. 2018. Nat Commun. 9:5079. PubMed
  5. Gu SS, et al. 2020. Genome Biol. 21:263. PubMed
  6. Frey BF, et al. 2018. J Immunol. 200:1853. PubMed
  7. Allen L 2004. J Immunol. 173:835. PubMed
RRID
AB_313736 (BioLegend Cat. No. 116601)

Antigen Details

Structure
MHC class I
Distribution

Nucleated cells of the H-2Kd haplotype

Function
Antigen presentation
Ligand/Receptor
CD3/TCR, CD8
Biology Area
Immunology, Innate Immunity
Molecular Family
MHC Antigens
Antigen References
  1. Watts C. 1997. Annu. Rev. Immunol. 15:821.
  2. Pamer E, et al. 1998. Annu. Rev. Immunol. 16:323.
  3. York I, et al. 1996. Annu. Rev. Immunol. 14:369.
Gene ID
14972 View all products for this Gene ID
UniProt
View information about H-2Kd on UniProt.org
Go To Top Version: 3    Revision Date: 08.31.2022

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account