Spark Blue™ 550 anti-human TCR Vα24-Jα18 (Flexi-Fluor™) Antibody

Pricing & Availability
Clone
6B11 (See other available formats)
Regulatory Status
RUO
Other Names
TCR Vα24-Jα18, TCR Vα24-JαQ, invariant NKT cell, iNKT
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Save
285264 50 µg 316€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Encoded by the TCR Vα24-Jα18 germline configuration, Vα24-JαQ is expressed on a subset of NKT cells, namely invariant NKT (iNKT). Vα24-JαQ TCR interacts with the glycolipid loaded MHC class 1b molecule CD1d, inducing activation and subsequent cytokine production. iNKT cells have been implicated in immune regulation, tumor surveillance, and host response to pathogens. While iNKT cells occur at low frequency in the blood, assorted chemokines contribute to their tissue homing potential.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Reported Reactivity
Rhesus, Pigtailed Macaque, Sooty Mangabey
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark Blue™ 550 under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage

Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.

Excitation Laser
Blue Laser (488 nm)
Application Notes

The 6B11 antibody recognizes the invariant CDR3 region of TCR Va24-JaQ.

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References
  1. Rout N, et al. 2010. PLoS One 5:e9787. (FC)

Antigen Details

Structure
Invariant CDR3 region of TCR Vα24-JαQ
Distribution

Invariant NKT cells

Ligand/Receptor
Glycolipid loaded CD1d
Cell Type
NKT cells
Biology Area
Immunology
Molecular Family
TCRs
Antigen References
  1. Thomas SY, et al. 2003. J. Immunol. 171:2571.
  2. Exley MA, et al. 2008. Eur. J. Immunol. 38:1756.
  3. Montoya CJ, et al. 2007. Immunology. 122:1.
  4. Gansuvd B, et al. 2003. J. Immunol. 171:2904.
Gene ID
NA
UniProt
View information about TCR Valpha24-Jalpha18 on UniProt.org

Related FAQs

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

Other Formats

View All TCR Vα24-Jα18 Reagents Request Custom Conjugation
Description Clone Applications
Purified anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
PE anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
FITC anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
APC anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
PE/Cyanine7 anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
PerCP/Cyanine5.5 anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
Brilliant Violet 421™ anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
Brilliant Violet 510™ anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
PE/Dazzle™ 594 anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
Brilliant Violet 711™ anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
TotalSeq™-A0584 anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 PG
TotalSeq™-C0584 anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 PG
Brilliant Violet 605™ anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
Brilliant Violet 785™ anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
TotalSeq™-B0584 anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 PG
APC/Fire™ 750 anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
APC/Cyanine7 anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
PerCP/Fire™ 780 anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
PerCP/Fire™ 806 anti-human TCR Vα24-Jα18 (iNKT cell) 6B11 FC
Spark Red™ 718 anti-human TCR Vα24-Jα18 (Flexi-Fluor™) 6B11 FC
Spark Blue™ 574 anti-human TCR Vα24-Jα18 (Flexi-Fluor™) 6B11 FC
Spark Blue™ 550 anti-human TCR Vα24-Jα18 (Flexi-Fluor™) 6B11 FC
Go To Top Version: 1    Revision Date: 09.12.2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account