IMPORTANT NOTICE: Our email addresses will soon change. Learn more >>

Spark Blue™ 550 anti-rat CD90/mouse CD90.1 (Thy1.1) (Flexi-Fluor™) Antibody

Pricing & Availability
Clone
OX-7 (See other available formats)
Regulatory Status
RUO
Other Names
Thy-1, Thy-1.1
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Save
285271 50 µg 269€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD90, also known as Thy-1, is a 28-30 kD GPI-linked membrane glycoprotein. It is a member of the immunoglobulin superfamily and has been shown to interact with CD45 in signal transduction during lymphocyte proliferation and differentiation. CD90 is expressed on hematopoietic stem cells, neurons, thymocytes, peripheral T cells, fibroblasts, stromal cells.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Rat
Reported Reactivity
Rabbit, Guinea Pig
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Rat thymocyte Thy-1 antigen
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark Blue™ 550 under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage

Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.

Excitation Laser
Blue Laser (488 nm)
Application Notes

The OX-7 antibody reacts with rat CD90 and mouse CD90.1 (Thy-1.1) (which is expressed by mouse strains of AKR/J, PL, and FVB/N), but not mouse CD90.2.

Additional reported applications (for the relevant formats) include: immunohistochemical7 and immunofluorescent8 staining of acetone-fixed frozen sections and zinc-fixed paraffin-embedded sections, immunoprecipitation1, Western blotting1, in vitro activation of leukocytes2, induction of endothelial cell permeability3, induction of apoptosis in glomerular mesangial cells, and induction of glomerulonephritis in vivo4.

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References
  1. Jeng CJ, et al. 1998. J. Cell Biol. 140:685. (IP, WB)
  2. Nakashima I, et al. 1991. J. Immunol. 147:1153.
  3. Ishizu A, et al. 1995. Int. Immunol. 7:1939.
  4. Eitner F. 1997. Kidney. Int. 51:69.
  5. Kawachi H, et al. 1992. Clin. Exp. Immunol. 88:399. (WB)
  6. Dyer KD, et al. 2007. J. Immunol. 179:1693. (FC) PubMed
  7. Daniel C, et al. 2012. Lab Invest. 92:812. (IHC-P)
  8. Li B, et al. 2006. Kidney Int. 69:323. (ICC)
  9. Uchimura H, et al. 2005. J Am Soc Nephrol. 16(4):997-1004. (IHC-F)
  10. Inagi R, et al. 2008. J Am Soc Nephrol. 19(5):915-22. (IHC-P)

Antigen Details

Structure
Ig superfamily, GPI-anchored membrane glycoprotein, 28-30 kD
Distribution

Hematopoietic stem cells, thymocytes, a subset of peripheral blood T cells, early myeloid and erythroid progenitors, immature B cells, neurons, activated endothelium, mast cells, dendritic cells, glomeruli

Function
Adhesion, signal transduction, lymphocyte co-stimulation, proliferation and differentiation of hematopoietic stem cells
Ligand/Receptor
Interacts with CD45
Cell Type
B cells, Dendritic cells, Endothelial cells, Hematopoietic stem and progenitors, Mast cells, Neurons, T cells, Thymocytes
Biology Area
Immunology
Molecular Family
CD Molecules
Antigen References

1. Campbell DG, et al. 1981. Biochem. J. 195:15.
2. Hosseinzadeh H, et al. 1993. J. Immunol. 150:1670.

Gene ID
21838 View all products for this Gene ID 24832 View all products for this Gene ID
UniProt
View information about CD90/CD90.1 on UniProt.org

Related FAQs

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

Other Formats

View All CD90/CD90.1 Reagents Request Custom Conjugation
Description Clone Applications
PE/Cyanine7 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Purified anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC,IHC-F,ICC,IHC-P,IP,WB
FITC anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Alexa Fluor® 488 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC,IHC-F
Alexa Fluor® 647 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC,IHC-F
PerCP/Cyanine5.5 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
APC/Cyanine7 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Pacific Blue™ anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
PerCP anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
PE anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
APC anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Alexa Fluor® 700 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Biotin anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Brilliant Violet 421™ anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Brilliant Violet 650™ anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Brilliant Violet 510™ anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Brilliant Violet 605™ anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Brilliant Violet 711™ anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
PE/Dazzle™ 594 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
APC/Fire™ 750 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Alexa Fluor® 594 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 IHC-F
TotalSeq™-A0380 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 PG
TotalSeq™-B0380 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 PG
TotalSeq™-C0380 anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 PG
Brilliant Violet 785™ anti-rat CD90/mouse CD90.1 (Thy1.1) OX-7 FC
Spark Blue™ 550 anti-rat CD90/mouse CD90.1 (Thy1.1) (Flexi-Fluor™) OX-7 FC
Spark Blue™ 574 anti-rat CD90/mouse CD90.1 (Thy1.1) (Flexi-Fluor™) OX-7 FC
Spark Red™ 718 anti-rat CD90/mouse CD90.1 (Thy1.1) (Flexi-Fluor™) OX-7 FC
Go To Top Version: 1    Revision Date: 01.17.2025

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account