Alexa Fluor® 647 Goat anti-mouse IgG (minimal x-reactivity) Antibody

Pricing & Availability
Clone
Poly4053 (See other available formats)
Regulatory Status
RUO
Isotype
Goat Polyclonal IgG
Ave. Rating
Submit a Review
Product Citations
publications
Poly4053_A647_IgG_Antibody_1_111120
Human paraffin-embedded tonsil tissue slices were prepared with a standard protocol of deparaffinization and rehydration. Antigen retrieval was done with Tris-Buffered Saline 1X (1.0M, pH 7.4) at 95°C for 40 minutes. Tissue was washed with PBS/ 0.05% Tween 20 twice for five minutes and blocked with 5% FBS and 0.2% gelatin for 30 minutes. Then, the tissue was stained with 10 µg/ml of purified anti-human CD309/VEGFR2 (clone A16085I) and Alexa Fluor® 594 anti-human PNAD (clone MECA-79) (green) at 4°C overnight, followed by 2.5 µg/ml of Alexa Fluor® 647 anti-mouse IgG (clone Poly4053) (red) for two hours at room temperature. The image was captured with a 10X objective.
  • Poly4053_A647_IgG_Antibody_1_111120
    Human paraffin-embedded tonsil tissue slices were prepared with a standard protocol of deparaffinization and rehydration. Antigen retrieval was done with Tris-Buffered Saline 1X (1.0M, pH 7.4) at 95°C for 40 minutes. Tissue was washed with PBS/ 0.05% Tween 20 twice for five minutes and blocked with 5% FBS and 0.2% gelatin for 30 minutes. Then, the tissue was stained with 10 µg/ml of purified anti-human CD309/VEGFR2 (clone A16085I) and Alexa Fluor® 594 anti-human PNAD (clone MECA-79) (green) at 4°C overnight, followed by 2.5 µg/ml of Alexa Fluor® 647 anti-mouse IgG (clone Poly4053) (red) for two hours at room temperature. The image was captured with a 10X objective.
Compare all formats See Alexa Fluor® 647 spectral data
Cat # Size Price Quantity Check Availability Save
405322 100 µg 183 CHF
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

This polyclonal goat anti-mouse IgG antibody reacts with the heavy chains of mouse IgG and with the light (kappa and lambda) chains common to most mouse immunoglobulins. No cross-reactivity has been detected against non-immunoglobulin serum proteins. This antibody has been solid-phase absorbed to ensure minimal cross-reaction with rat, human, bovine, horse, and rabbit immunoglobulins, but it may have minimal cross-reactivity with other subclasses of mouse immunoglobulins.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Polyclonal
Host Species
Goat
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA)
Preparation
The antibody was purified by affinity chromatography and conjugated with Alexa Fluor® 647 under optimal conditions.
Concentration
0.5 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested
IHC-P - Verified

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.5 µg per million cells in 100 µL volume. For immunohistochemistry on formalin-fixed paraffin-embedded tissue sections, the suggested use of this reagent is 2.5 - 5.0 µg/mL. It is recommended that the reagent be titrated for optimal performance for each application.

* Alexa Fluor® 647 has a maximum emission of 668 nm when it is excited at 633 nm / 635 nm.


Alexa Fluor® and Pacific Blue™ are trademarks of Life Technologies Corporation.

View full statement regarding label licenses
Excitation Laser
Red Laser (633 nm)
Application Notes

This polyclonal goat anti-mouse IgG antibody is useful for capture or detection of mouse IgG in ELISA.

Application References

(PubMed link indicates BioLegend citation)
  1. Scotta C, et al. 2008. J Immunol. 181:1025-33. PubMed
  2. Gao X, et al. 2014. Cell Mol Neurobiol. 34:257-68 (ICC)
  3. Winters T, et al. 2014. EMBO J. 33:1256-70.
Product Citations
  1. Chen BR, et al. 2022. Bio Protoc. 12:e4413. PubMed
  2. Della Marina A, et al. 2021. Cells. 10:. PubMed
  3. Wong JJ, et al. 2021. Sci Adv. 7:. PubMed
  4. özdilek A, et al. 2020. Proc Natl Acad Sci U S A. 117:1280. PubMed
  5. Jung WH, et al. 2019. Cells. 8:813. PubMed
  6. Middleton DR, et al. 2021. J Bacteriol. 203:. PubMed
  7. Chen BR, et al. 2021. Elife. 10:. PubMed
  8. Omori S, et al. 2021. Cell Reports. 34(6):108734. PubMed
  9. Pruett L, et al. 2020. Laryngoscope. 130:2432. PubMed
  10. Bose S, et al. 2020. Nat Biomed Eng. 4:814. PubMed
  11. Khan AA, et al. 2022. Bioconjug Chem. . PubMed
  12. Smith R, et al. 2017. Biophys J. 10.1016/j.bpj.2017.05.005. PubMed
  13. Zhao Y, et al. 2020. Immunity. 51(6):1059-1073.e9.. PubMed
  14. Zheng W, et al. 2020. Nature. 577:543. PubMed
  15. Pandey N, et al. 2020. J Cell Biol. 219:00:00. PubMed
  16. Scott WA, et al. 2021. PLoS Genet. 17:e1009909. PubMed
RRID
AB_2563045 (BioLegend Cat. No. 405322)

Related FAQs

There are no FAQs for this product.

Other Formats

View All IgG Reagents Request Custom Conjugation
Description Clone Applications
APC Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
Biotin Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
FITC Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
HRP Goat anti-mouse IgG (minimal x-reactivity) Poly4053 ELISA,IHC,WB
PE Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
Purified Goat anti-mouse IgG (minimal x-reactivity) Poly4053 ELISA,FC,WB,IHC
Cyanine3 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 ICC
PE/Cyanine7 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
PerCP/Cyanine5.5 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
DyLight™ 488 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC,ICC
DyLight™ 649 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
Alexa Fluor® 594 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 ICC,IHC-F,IHC-P
APC/Cyanine7 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
Brilliant Violet 421™ Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC,ICC
Alexa Fluor® 488 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC,IHC-F
Alexa Fluor® 647 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC,IHC-P
Alexa Fluor® 555 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 ICC
Brilliant Violet 605™ Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
Brilliant Violet 510™ Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
PE/Dazzle™ 594 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
PerCP Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
APC/Fire™ 750 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC
Spark YG™ 570 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 FC,IHC-P
Spark Red™ 718 Goat anti-mouse IgG (minimal x-reactivity) Poly4053 IHC-P,IHC-F,ICC
Go To Top Version: 4    Revision Date: 11.11.2020

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account