ELISA MAX™ Deluxe Set Human CCL20 (MIP-3a)

Pricing & Availability
Regulatory Status
RUO
Other Names
CCL20 ELISA Kit, CK64, LARC, MIP-3α
Ave. Rating
Submit a Review
Product Citations
publications
Hu_CCL20_MIP3alpha_ELISAMAX_Deluxe_042817
  • Hu_CCL20_MIP3alpha_ELISAMAX_Deluxe_042817
Cat # Size Price Quantity Check Availability Save
441404 5 plates 278€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Please contact our sales representative for bulk pricing quotations.

CCL20 (MIP-3α) belongs to the CC chemokine family. Human CCL20 is a protein of 96 amino acids, which shares 28% amino acid identity with MIP-1β and 64% amino acid sequence identity with mouse CCL20. CCL20 is produced by activated monocytes, T cells, neutrophils, endothelial cells, epithelial cells and fibroblasts. Its expression is induced by lipopolysaccharide (LPS) and inflammatory cytokines such as tumor necrosis factor, IL-1β and interferon-γ, and downregulated by IL-10.

CCL20 is the ligand for chemokine receptor CCR6, which is expressed on memory T cells, B cells, and immature dendritic cells (DCs). Therefore, it is involved in the regulation of DC trafficking and recruitment and activation of T cells. CCL20 also has potent antimicrobial activity.

Upregulation of CCL20 plays important roles in autoimmune pathogenesis of the central nerve system (MS), pathogenesis of encephalomyelitis, psoriasis, rheumatoid arthritis, and inflammatory bowel diseases. CCL20 is also involved in various cancers, such as gastrointestinal cancers, pancreatic cancer, hepatocellular carcinoma, and breast cancer.

The BioLegend ELISA MAX™ Deluxe Set is a sandwich Enzyme-Linked Immunosorbent Assay (ELISA). The human CCL20 (MIP-3α) capture antibody is first coated on a 96-well plate. Standards and samples are added to the wells and CCL20 (MIP-3α) binds to the immobilized capture antibody. Next, biotinylated anti-human CCL20 (MIP-3α) detection antibody is added, producing an antibody-antigen-antibody “sandwich”. Avidin horseradish peroxidase is subsequently added, followed by TMB Substrate Solution, producing a blue color in proportion to the concentration of CCL20 (MIP-3α) present in the sample. Finally, the Stop Solution changes the reaction color from blue to yellow, and the microwell absorbance is read at 450 nm with a microplate reader.

Product Details
Technical Data Sheet (pdf)

Kit Contents

Kit Contents
  • Human CCL20 (MIP-3α) ELISA MAX™ Capture Antibody (200X)
  • Human CCL20 (MIP-3α) ELISA MAX™ Detection Antibody (200X)
  • Human CCL20 (MIP-3α) Standard
  • Avidin-HRP (1000X)
  • Substrate Solution F
  • Coating Buffer A (5X)
  • Assay Diluent A (5X)

Product Details

Verified Reactivity
Human
Application

ELISA

 
As a part of BioLegend's efforts to go green, each new lot of the ELISA MAX™ sets will include a summarized version of its manual. Click here for more information.
Sensitivity
2.5 pg/mL
Standard Range
2.5-160 pg/mL
Materials Not Included
  • Microwell plates: 96-well Nunc MaxiSorp™ is recommended.
  • PBS (Phosphate-Buffered Saline): 8.0 g NaCl, 1.16 g Na2HPO4,
    0.2 g KH2PO4, 0.2 g KCl, add deionized water to 1 L; pH to 7.4, 0.2 μm
    filtered
  • Wash Buffer: BioLegend Cat. No. 421601 is recommended, or PBS +
    0.05% Tween-20
  • Stop Solution: BioLegend Cat. No. 423001 is recommended, or acid
    solution, e.g. 2N H2SO4
  • Plate Sealers: BioLegend Cat. No. 423601 is recommended
  • Deionized (DI) water
  • A microplate reader capable of measuring absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 2 μL to 1 mL
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Absorbent paper

Antigen Details

Biology Area
Cell Biology, Signal Transduction
Molecular Family
Cytokines/Chemokines
Gene ID
6364 View all products for this Gene ID
UniProt
View information about CCL20 on UniProt.org

Related FAQs

Do the ELISA MAX™ Deluxe Sets come with plates?

No, ELISA MAX™ Deluxe Sets do not come with plates. Coating Buffer and Assay Diluent (for blocking and dilutions) are included in these sets. Plates can be ordered separately (Cat No. 423501), and instructions for coating the plates are in the sets’ product manuals.

Go To Top Version: 4    Revision Date: 11/16/2022

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account