Spark Red™ 718 anti-human CD326 (Ep-CAM) (Flexi-Fluor™) Antibody

Pricing & Availability
Clone
9C4 (See other available formats)
Regulatory Status
RUO
Other Names
Ep-CAM, tumor associated calcium signal transducer 1, epithelial cell surface antigen, epithelial glycoprotein 2, EGP2, adenocarcinoma associated antigen, TROP1
Isotype
Mouse IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Save
285057 50 µg 300€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD326 is also known as Ep-CAM, tumor associated calcium signal transducer 1, epithelial cell surface antigen, epithelial glycoprotein 2, EGP2, adenocarcinoma associated antigen, and TROP1. CD326 is a type I transmembrane protein containing six disulfide bridges and one THYRO domain. This cell surface glycosylated 40 kD protein is highly expressed in bone marrow, colon, lung, and most normal epithelial cells and is expressed on carcinomas of gastrointestinal origin. Recently, it has been reported that CD326 expression occurs during the early steps of erythrogenesis. CD326 functions as a homotypic calcium-independent cell adhesion molecule and is believed to be involved in carcinogenesis by its ability to induce genes involved in cellular metabolism and proliferation. CD326 antigen is an immunotherapeutic target for the treatment of human carcinomas.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
DU.4475 breast carcinoma
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark Red™ 718 under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage
Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.
Excitation Laser
Red Laser (633 nm)
Application Notes

Additional reported applications (for the revelant formats) include: immunofluorescence, immunohistochemistry3, and spatial biology (IBEX)4,5.

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References

(PubMed link indicates BioLegend citation)
  1. Lammers R, et al. 2002. Exp. Hematol. 30:537.
  2. Schultz LD, et al. 2010. P. Natl. Acad. Sci. USA 107:13022. PubMed
  3. Human Protein Atlas http://www.proteinatlas.org/ENSG00000119888/antibody (IHC)
  4. Radtke AJ, et al. 2020. Proc Natl Acad Sci USA. 117:33455-33465. (SB) PubMed
  5. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed
RRID
AB_3106318 (BioLegend Cat. No. 285057)

Antigen Details

Structure
Type I transmembrane protein, contains six disulfide bridges, one THYRO domain, approximate molecular weight 40 kD.
Distribution

Highly expressed in bone marrow, colon, lung, and most normal epithelial cells. Also highly expressed on carcinomas of gastrointestinal origin. Expressed during early erythrogenesis.

Function
Homotypic calcium-independent cell adhesion. CD326 is believed to be involved in carcinogenesis by its ability to induce genes involved in cellular metabolism and proliferation.
Modification
Glycosylated.
Cell Type
Embryonic Stem Cells, Epithelial cells
Biology Area
Cell Biology, Immunology, Stem Cells
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References

1. Strnad J, et al. 1989. Cancer Res. 49:314.
2. Munz M, et al. 2004. Oncogene 23:5748.
3. Rao CG, et al. 2005. Int. J. Oncol. 27:49.

Gene ID
4072 View all products for this Gene ID
UniProt
View information about CD326 on UniProt.org

Related FAQs

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

Other Formats

View All CD326 Reagents Request Custom Conjugation
Description Clone Applications
Purified anti-human CD326 (EpCAM) 9C4 FC,ICC,IHC
FITC anti-human CD326 (EpCAM) 9C4 FC
PE anti-human CD326 (EpCAM) 9C4 FC
APC anti-human CD326 (EpCAM) 9C4 FC
Alexa Fluor® 488 anti-human CD326 (EpCAM) 9C4 FC,SB
Alexa Fluor® 647 anti-human CD326 (EpCAM) 9C4 FC,ICC,SB
PerCP/Cyanine5.5 anti-human CD326 (EpCAM) 9C4 FC,SB
Biotin anti-human CD326 (EpCAM) 9C4 FC
Pacific Blue™ anti-human CD326 (EpCAM) 9C4 FC
Brilliant Violet 421™ anti-human CD326 (EpCAM) 9C4 FC
PE/Cyanine7 anti-human CD326 (EpCAM) 9C4 FC
Brilliant Violet 605™ anti-human CD326 (EpCAM) 9C4 FC
Brilliant Violet 650™ anti-human CD326 (EpCAM) 9C4 FC
Alexa Fluor® 594 anti-human CD326 (EpCAM) 9C4 IHC-P,ICC,SB
Purified anti-human CD326 (EpCAM) (Maxpar® Ready) 9C4 FC,CyTOF®
PE/Dazzle™ 594 anti-human CD326 (EpCAM) 9C4 FC
APC/Fire™ 750 anti-human CD326 (EpCAM) 9C4 FC
Brilliant Violet 510™ anti-human CD326 (EpCAM) 9C4 FC
Brilliant Violet 785™ anti-human CD326 (EpCAM) 9C4 FC
Brilliant Violet 711™ anti-human CD326 (Ep-CAM) 9C4 FC
TotalSeq™-A0123 anti-human CD326 (Ep-CAM) 9C4 PG
APC/Cyanine7 anti-human CD326 (Ep-CAM) 9C4 FC
Alexa Fluor® 700 anti-human CD326 (EpCAM) 9C4 FC
TotalSeq™-C0123 anti-human CD326 (Ep-CAM) 9C4 PG
TotalSeq™-B0123 anti-human CD326 (Ep-CAM) 9C4 PG
PE/Cyanine5 anti-human CD326 (Ep-CAM) 9C4 FC
TotalSeq™-D0123 anti-human CD326 (Ep-CAM) 9C4 PG
Spark UV™ 387 anti-human CD326 (Ep-CAM) 9C4 FC
Spark Red™ 718 anti-human CD326 (Ep-CAM) (Flexi-Fluor™) 9C4 FC
Spark Blue™ 574 anti-human CD326 (Ep-CAM) (Flexi-Fluor™) 9C4 FC
Spark Blue™ 550 anti-human CD326 (Ep-CAM) (Flexi-Fluor™) 9C4 FC
Go To Top Version: 1    Revision Date: 02/07/2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account