Purified anti-human CD123 (Maxpar® Ready) Antibody

Pricing & Availability
Clone
6H6 (See other available formats)
Regulatory Status
RUO
Other Names
IL-3Rα, IL-3 Receptor alpha
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
6H6_Purified_CD123_CyTOF_Antibody_112113
Human lysed whole blood stained with 151Eu anti-CD123 (6H6) and 172Yb anti-CD38 (HIT2). Total cells, excluding lymphocytes, are displayed in the analysis.
  • 6H6_Purified_CD123_CyTOF_Antibody_112113
    Human lysed whole blood stained with 151Eu anti-CD123 (6H6) and 172Yb anti-CD38 (HIT2). Total cells, excluding lymphocytes, are displayed in the analysis.
Compare all formats
Cat # Size Price Quantity Check Availability Save
306027 100 µg 104€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD123 is the 70 kD transmembrane α chain of the IL-3 receptor. Alone, CD123 binds IL-3 with low affinity; when CD123 associates with CD131 (common β chain), it binds IL-3 with high affinity. CD123 does not transduce intracellular signals upon binding IL-3 and requires the β chain for this function. CD123 is expressed by myeloid precursors, macrophages, dendritic cells, mast cells, basophils, megakaryocytes, and some B cells.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Reported Reactivity
Rhesus
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Human IL-3Rα transfected COS cells.
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and EDTA.
Preparation
The antibody was purified by affinity chromatography.
Concentration
1.0 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C.
Application

FC - Quality tested
CyTOF® - Verified

Recommended Usage

This product is suitable for use with the Maxpar® Metal Labeling Kits. For metal labeling using Maxpar® Ready antibodies, proceed directly to the step to Partially Reduce the Antibody by adding 100 µl of Maxpar® Ready antibody to 100 µl of 4 mM TCEP-R in a 50 kDa filter and continue with the protocol. Always refer to the latest version of Maxpar® User Guide when conjugating Maxpar® Ready antibodies.

Application Notes

Clone 6H6 does not inhibit IL-3 binding to low- or high-affinity IL-3Rs. Additional reported applications (for the relevant formats) include: Western blotting1, immunoprecipitation1, and immunohistochemical staining of acetone-fixed frozen sectionsand also paraformaldehyde fixed paraffin embedded tissue7.

Additional Product Notes

Maxpar® is a registered trademark of Standard BioTools Inc.

Application References
  1. Sun Q, et al. 1996. Blood 87:83. (IP, WB)
  2. Herling M, et al. 2003. Blood 101:5007. (IHC)
  3. Charles N, et al. 2010. Nat. Med. 16:701. (FC) PubMed
  4. Martin-Gayo E, et al. 2010. Blood 115:5366. PubMed
  5. Chen SC, et al. 2010. Arch Dermatol Res. 302:113. PubMed
  6. Liu Y, et al. 2012. Food Chem Toxicol. 50:1920. PubMed
  7. Peduzzi E, et al. 2007. J. Invest. Dermatol. 127:638. (IHC)
Product Citations
  1. Gañán-Gómez I, et al. 2022. Nat Med. . PubMed
  2. Jordan S, et al. 2020. Cell. 178(5):1102-1114.e17.. PubMed
RRID
AB_2562823 (BioLegend Cat. No. 306027)

Antigen Details

Structure
Ig superfamily, type I transmembrane glycoprotein, associates with CDw131, 70 kD
Distribution

Myeloid precursors, basophils, mast cells, macrophages, dendritic cells, megakaryocytes, subset of lymphocytes

Function
Hematopoietic cell proliferation, differentiation
Ligand/Receptor
IL-3
Cell Type
Basophils, Dendritic cells, Hematopoietic stem and progenitors, Lymphocytes, Macrophages, Mast cells, Megakaryocytes
Biology Area
Immunology
Molecular Family
CD Molecules, Cytokine/Chemokine Receptors
Antigen References

1. Miyajima A, et al. 1993. Blood 82:1960.

Gene ID
3563 View all products for this Gene ID
UniProt
View information about CD123 on UniProt.org

Related FAQs

Can I obtain CyTOF data related to your Maxpar® Ready antibody clones?

We do not test our antibodies by mass cytometry or on a CyTOF machine in-house. The data displayed on our website is provided by Fluidigm®. Please contact Fluidigm® directly for additional data and further details.

http://techsupport.fluidigm.com/

Can I use Maxpar® Ready format clones for flow cytometry staining?

We have not tested the Maxpar® Ready antibodies formulated in solution containing EDTA for flow cytometry staining. While it is likely that this will work in majority of the situations, it is best to use the non-EDTA formulated version of the same clone for flow cytometry testing. The presence of EDTA in some situations might negatively affect staining.

I am having difficulty observing a signal after conjugating a metal tag to your Maxpar® antibody. Please help troubleshoot.

We only supply the antibody and not test that in house. Please contact Fluidigm® directly for troubleshooting advice: http://techsupport.fluidigm.com/

Is there a difference between buffer formulations related to Maxpar® Ready and purified format antibodies?

The Maxpar® Ready format antibody clones are formulated in Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and EDTA. The regular purified format clones are formulated in solution that does not contain any EDTA. Both formulations are however without any extra carrier proteins.

Other Formats

View All CD123 Reagents Request Custom Conjugation
Description Clone Applications
Biotin anti-human CD123 6H6 FC
PE anti-human CD123 6H6 FC,SB
Purified anti-human CD123 6H6 FC,CyTOF®,IHC-F,IP,WB
PE/Cyanine5 anti-human CD123 6H6 FC
PE/Cyanine7 anti-human CD123 6H6 FC
APC anti-human CD123 6H6 FC
FITC anti-human CD123 6H6 FC
PerCP/Cyanine5.5 anti-human CD123 6H6 FC
Brilliant Violet 421™ anti-human CD123 6H6 FC
Brilliant Violet 650™ anti-human CD123 6H6 FC
Brilliant Violet 510™ anti-human CD123 6H6 FC
Alexa Fluor® 647 anti-human CD123 6H6 FC
Brilliant Violet 605™ anti-human CD123 6H6 FC
Purified anti-human CD123 (Maxpar® Ready) 6H6 FC,CyTOF®
Brilliant Violet 711™ anti-human CD123 6H6 FC
Brilliant Violet 785™ anti-human CD123 6H6 FC
PE/Dazzle™ 594 anti-human CD123 6H6 FC
Alexa Fluor® 488 anti-human CD123 6H6 FC
PE/Cyanine7 anti-human CD123 6H6 FC
TotalSeq™-A0064 anti-human CD123 6H6 PG
Alexa Fluor® 700 anti-human CD123 6H6 FC
APC/Fire™ 750 anti-human CD123 6H6 FC
Pacific Blue™ anti-human CD123 6H6 FC
TotalSeq™-C0064 anti-human CD123 6H6 PG
TotalSeq™-B0064 anti-human CD123 6H6 PG
TotalSeq™-D0064 anti-human CD123 6H6 PG
PerCP anti-human CD123 6H6 FC
GMP PE/Cyanine7 anti-human CD123 6H6 FC
APC/Fire™ 810 anti-human CD123 Antibody 6H6 FC
APC anti-human CD123 6H6 FC
PE anti-human CD123 6H6 FC
Pacific Blue™ anti-human CD123 6H6 FC
Spark Red™ 718 anti-human CD123 (Flexi-Fluor™) 6H6 FC
PerCP anti-human CD123 6H6 FC
PerCP/Cyanine5.5 anti-human CD123 6H6 FC
Go To Top Version: 4    Revision Date: 07/22/2022

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account