IMPORTANT NOTICE: Our email addresses will soon change. Learn more >>

True-Nuclear™ Transcription Factor Buffer Set

Pricing & Availability
Regulatory Status
RUO
Other Names
Transcription Factor Fixation/Permeabilization Buffer Set
Ave. Rating
Submit a Review
Product Citations
137 publications
Transcription_Factor_F_P_Buffer_1_ICFC_012915
Human peripheral blood lymphocytes were surface stained with CD3 APC and then treated with True-Nuclear™ Transcription Factor Buffer Set. Cells were then stained with T-bet (clone 4B10) Brilliant Violet 421™ (top) or mouse IgG1, κ Brilliant Violet 421™ isotype control (bottom).
  • Transcription_Factor_F_P_Buffer_1_ICFC_012915
    Human peripheral blood lymphocytes were surface stained with CD3 APC and then treated with True-Nuclear™ Transcription Factor Buffer Set. Cells were then stained with T-bet (clone 4B10) Brilliant Violet 421™ (top) or mouse IgG1, κ Brilliant Violet 421™ isotype control (bottom).
  • Transcription_Factor_F_P_Buffer_2_ICFC_012915
Cat # Size Price Quantity Check Availability Save
424401 120 tests 132€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

BioLegend's True-Nuclear™ Transcription Factor Buffer Set has been specially formulated for intracellular staining with minimum effect on the surface fluorochrome staining.

See the advantages of True-Nuclear™ Transcription Factor Buffer Set in this brief webinar: biolegend.com/true_nuclear_webinar.


 

Caution: The True-Nuclear™ Transcription Factor Buffer Set contains paraformaldehyde, which is toxic and mutagenic. Please handle with caution. Wear gloves, lab coats, and necessary protection to avoid direct contact. 

Product Details
Technical Data Sheet (pdf)

Product Details

Storage & Handling
Store between 2°C and 8°C. Do not freeze.
Application

ICFC - Quality tested

Recommended Usage

Prepare fresh Transcription Factor Fix working solution by diluting the 4X Fix Concentrate (1 part) with the Fix Diluent (3 parts). 1 mL of the 1X Fix working solution is needed for each tube.

Prepare a 1X working solution of the Perm Buffer by diluting the 10X Perm Buffer with distilled water. 6.5 mL of 1X Perm Buffer is needed for each sample of tube.

NOTE: The 10X Perm Buffer may have crystallization or precipitation when it is stored at 2-8°C; however, this is normal and does not affect the buffer's performance. If there is a heavy precipitation observed after dilution to 1X working solution, it can be filtered to clarify the solution.

Application Notes

Buffer Set Contents:

  • True-Nuclear™ 4X Fix Concentrate (30 mL)
  • True-Nuclear™ Fix Diluent (100 mL)
  • True-Nuclear™ 10X Perm Buffer (100 mL)

 

Additional Product Notes

View more applications data using this product to stain Veri-Cells™ lyophilized control cells, to detect transcription factors, and to study TIGIT in our Scientific Poster Library.

Product Citations
  1. Wang L, et al. 2019. Front Pharmacol. 1.342361111. PubMed
  2. Ogawa T, et al. 2020. J Immunol. 205:907. PubMed
  3. Ajith A, et al. 2021. Front Immunol. 12:687715. PubMed
  4. Manso BA, et al. 2021. STAR Protoc. 2:100485. PubMed
  5. Wu HJ, et al. 2021. Nat Commun. 12:4897. PubMed
  6. Zeng N, et al. 2022. EMBO Rep. 23:e53302. PubMed
  7. Douglass SM, et al. 2021. Cancer Res. 81:658. PubMed
  8. Capelle CM, et al. 2022. Immunology. 165:428. PubMed
  9. Ellis GI, et al. 2022. Cell Rep Med. 3:100614. PubMed
  10. Grant NL, et al. 2022. Cell Rep. 39:110826. PubMed
  11. Hu M, et al. 2022. Int J Mol Sci. 23: . PubMed
  12. Jou E, et al. 2022. Sci Immunol. 7:eabn0175. PubMed
See More

Antigen Details

Cell Type
Tregs
Biology Area
Immunology, Transcription Factors
Molecular Family
Nuclear Markers
Gene ID
NA

Related FAQs

There are no FAQs for this product.
Go To Top Version: 5    Revision Date: 05/20/2020

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587


Login / Register
Remember me
Forgot your password? Reset password?
Create an Account