Brilliant Violet 421™ anti-human CD184 (CXCR4) Antibody

Pricing & Availability
Clone
12G5 (See other available formats)
Regulatory Status
RUO
Workshop
VII 70204
Other Names
CXCR4, Fusin
Isotype
Mouse IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
12G5_BV421_041511
Human peripheral blood lymphocytes were stained with CD184 (clone 12G5) Brilliant Violet 421™ (filled histogram) or mouse IgG2a, κ Brilliant Violet 421™ isotype control (open histogram).
  • 12G5_BV421_041511
    Human peripheral blood lymphocytes were stained with CD184 (clone 12G5) Brilliant Violet 421™ (filled histogram) or mouse IgG2a, κ Brilliant Violet 421™ isotype control (open histogram).
Compare all formats See Brilliant Violet 421™ spectral data
Cat # Size Price Save
306517 25 tests ¥33,820
306518 100 tests ¥73,520
Description

CD184, also known as fusin or CXCR4, is a 45 kD seven transmembrane G-protein-linked CXC chemokine receptor. CD184 is widely expressed on blood and tissue cells, including B and T cells, monocytes, macrophages, dendritic cells, granulocytes, megakaryocytes/platelets, lymphoid, myeloid precursor cells, endothelial cells, epithelial cells, astrocytes, and neurons, among other tissue cells. CD184 is the receptor for CXC chemokine SDF-1, mediates blood cell migration, and is involved in B lymphopoiesis and myelopoiesis, cardiogenesis, blood vessel formation, and cerebellar development. CXCR4 is also a coreceptor of X4 HIV-1 and an alternative receptor for some isolates of HIV-2.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Human, Cynomolgus, Rhesus
Reported Reactivity
African Green, Baboon, Chimpanzee, Sooty Mangabey
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
CP-MAC-infected Sup-T1 cells
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA).
Preparation
The antibody was purified by affinity chromatography and conjugated with Brilliant Violet 421™ under optimal conditions.
Concentration
Lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µl per million cells in 100 µl staining volume or 5 µl per 100 µl of whole blood.

Brilliant Violet 421™ excites at 405 nm and emits at 421 nm. The standard bandpass filter 450/50 nm is recommended for detection. Brilliant Violet 421™ is a trademark of Sirigen Group Ltd.


Learn more about Brilliant Violet™.

This product is subject to proprietary rights of Sirigen Inc. and is made and sold under license from Sirigen Inc. The purchase of this product conveys to the buyer a non-transferable right to use the purchased product for research purposes only. This product may not be resold or incorporated in any manner into another product for resale. Any use for therapeutics or diagnostics is strictly prohibited. This product is covered by U.S. Patent(s), pending patent applications and foreign equivalents.
Excitation Laser
Violet Laser (405 nm)
Application Notes

Additional reported applications (for the relevant formats) include: immunohistochemical staining of paraffin-embedded tissue sections11, immunocytochemistry3, immunofluorescence microscopy2,6, and blocking of CD4-independent infection by HIV-2 and CD4-dependent infection by some T cell-tropic isolates of HIV-14,5. Clone 12G5 may not be suitable for Western blotting.10 The Ultra-LEAF™ purified antibody (Endotoxin <0.01 EU/µg, Azide-Free, 0.2 µm filtered) is recommended for functional assays (Cat. Nos. 306539 & 306540).

Application References

(PubMed link indicates BioLegend citation)
  1. McKnight A, et al. 1997. J. Virol. 71:1692.
  2. Endres MJ, et al. 1996. Cell 87:745. (Immunogen, IF)
  3. Volin MV, et al. 1998. Biochem. Biophys. Res. Commun. 242:46. (ICC)
  4. Berndt C, et al. 1998. P. Natl. Acad. Sci. USA 95:12556. (Block)
  5. Ullrich CK, et al. 2000. Blood 96:1438. (Block)
  6. Murga M, et al. 2005. Blood 105:1992. (IF)
  7. Thompson BD. 2007. J. Biol. Chem. 282:9547. (FC) PubMed
  8. Isnardi I, et al. 2010. Blood 115:5026. PubMed
  9. Yoshino N, et al. 2000. Exp. Anim. (Tokyo) 49:97. (FC)
  10. Fischer T, et al. 2008. PLoS One 3:e4069.
  11. Schmid BC, et al. 2004. Breast Cancer Res. Treat. 84:247. (IHC)
Product Citations
  1. Avital G, et al. 2022. Cell Rep. 41:111477. PubMed
  2. Hinks TSC, et al. 2019. Cell Rep. 28:3249. PubMed
  3. Saxena S, et al. 2016. Stem Cell Reports. 6: 692-703. PubMed
  4. Terenzi DC, et al. 2021. STAR Protoc. 2:100311. PubMed
  5. Tabler C, et al. 2014. J Virol. 88:4976. PubMed
  6. Mair B et al. 2019. Cell reports. 27(2):599-615 . PubMed
  7. Smulski C, et al. 2017. Cell Rep. 18(9):2189-2202. PubMed
  8. Xu J, et al. 2017. Clin Cancer Res. 23:4482. PubMed
  9. Garcia F, et al. 2020. Sci Rep. 10:14262. PubMed
  10. Demberg T, et al. 2014. Clin Immunol. 153:264. PubMed
  11. Gage BK, et al. 2020. Cell Stem Cell. 27(2):254-269.e9. PubMed
RRID
AB_10901163 (BioLegend Cat. No. 306517)
AB_10901163 (BioLegend Cat. No. 306518)

Antigen Details

Structure
Rhodopsin family, G-protein linked seven transmembrane glycoprotein, 45 kD
Distribution

T cells and B cells, dendritic cells, monocytes, granulocytes, hematopoietic progenitors, endothelial cells

Function
B lymphopoiesis and myelopoiesis, cardiogenesis, blood vessel formation, cerebellar development
Ligand/Receptor
SDF-1 receptor, coreceptor for X4 HIV-1
Cell Type
B cells, Dendritic cells, Endothelial cells, Granulocytes, Hematopoietic stem and progenitors, Mesenchymal Stem Cells, Monocytes, Neural Stem Cells, T cells, Tregs
Biology Area
Cell Biology, Immunology, Innate Immunity, Neuroinflammation, Neuroscience, Neuroscience Cell Markers, Stem Cells
Molecular Family
CD Molecules, Cytokine/Chemokine Receptors, GPCR
Antigen References

1. Berger E, et al. 1999. Annu. Rev. Immunol. 17:657.
2. Loetscher P, et al. 2000. Adv. Immunol. 74:127.
3. Murphy P, et al. 2000. Pharmacol. Rev. 52:145.

Gene ID
7852 View all products for this Gene ID
UniProt
View information about CD184 on UniProt.org

Related FAQs

What is the F/P ratio range of our BV421™ format antibody reagents?

It is lot-specific. On average it ranges between 2-4.

Does staining at room temperature or even at 37°C help for checking chemokine receptors expression?

Due to continuous recycling of many chemokine receptors, it may be worthwhile to consider staining at room temperature or at 37°C if the staining at lower temperature (which can potentially reduce receptor turnover) is not optimal.

Go To Top Version: 4    Revision Date: 08/22/2013

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account