Human Leptin is a 167 amino acid protein and approximately 16 kD in mass. Leptin is encoded by the obese (ob) gene and the gene locates on chromosome 7. Leptin is an adipocyte-derived hormone and mainly secreted by adipocyte. Small amounts of Leptin are expressed by the cells in the epithelium of the stomach and in the placenta. Leptin’s effects on body weight are mediated through impacts on hypothalamic center that control feeding behavior, hunger, body temperature, and energy expenditure. Leptin importantly regulates food intake, body weight, metabolism, energy expenditure, reproductive function, and adiposity through the hypothalamic Leptin receptor. Leptin is also the member of long-chain helical cytokine family.

The BioLegend LEGEND MAX™ Human Leptin ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (ELISA) with a 96-well strip plate that is pre-coated with a mouse monoclonal anti-human Leptin antibody. The detection antibody is a biotinylated mouse monoclonal anti-human Leptin antibody. This kit is specifically designed for the accurate quantitation of human Leptin in serum, plasma, and cell culture supernatant. This kit is analytically validated with ready-to-use reagents.

Product Details
Technical data sheet

Kit Contents

Kit Contents
  • Human Leptin Pre-coated 96-well Strip Microplate
  • Human Leptin Detection Antibody
  • Human Leptin Lyophilized Standard
  • Avidin-HRP
  • Substrate Solution F
  • Assay Buffer B
  • Wash Buffer (20X)
  • Stop Solution
  • Plate Sealers

Product Details

Verified Reactivity
Human
Application

ELISA

Sensitivity
31.7 ± 12.2 pg/mL
Standard Range
47 – 3000 pg/mL
Materials Not Included
  • Microplate reader able to measure absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 1 μL to 1,000 μL
  • Deionized water
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Plate Shaker
  • Polypropylene vials

Antigen Details

Cell Type
Endothelial cells, Fibroblasts
Biology Area
Angiogenesis, Cell Biology, Signal Transduction
Molecular Family
Cytokines/Chemokines, Enzymes and Regulators
Gene ID
NA
UniProt
View information about Leptin on UniProt.org

Related FAQs

In your LEGEND MAX™ ELISA Kits, there is a step that calls for washing the plates before adding sample. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The additional washing step is designed to remove these components before you start the assay. If you do not perform the washing, the effect on assay performance is negligible.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The wash buffer provided in all our LEGEND MAX™ kits is the same and the part numbers on the wash buffer bottles in these kits should be identical. For ELISA MAX™ Deluxe and ELISA MAX™ Standard Sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

In some cases, dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

Go To Top Version: 1    Revision Date: 09/14/2023

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account