PE anti-human RANTES (CCL5) Antibody

Pricing & Availability
Clone
VL1 (See other available formats)
Regulatory Status
RUO
Other Names
CCL5, C-C motif chemokine 5, Small-inducible cytokine A5, T-cell-specific protein RANTES, SIS-delta, T cell-specific protein P228, TCP228, Eosinophil-chemotactic cytokine, EoCP
Isotype
Mouse IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
VL1_PE_CCL5_Antibody_FC_1_010814
Overnight-cultured human peripheral blood lymphocytes (in the presence of monensin) were surface stained with CD3 APC and then intracellularly stained with CCL5 (clone VL1) PE (top) or mouse IgG2b, κ PE isotype control (bottom).
  • VL1_PE_CCL5_Antibody_FC_1_010814
    Overnight-cultured human peripheral blood lymphocytes (in the presence of monensin) were surface stained with CD3 APC and then intracellularly stained with CCL5 (clone VL1) PE (top) or mouse IgG2b, κ PE isotype control (bottom).
  • VL1_PE_CCL5_Antibody_FC_2_010814
Compare all formats See PE spectral data
Cat # Size Price Save
515503 25 tests ¥28,380
515504 100 tests ¥60,500
Description

RANTES (CCL5) is a member of the CC chemokine family. Its mature form consists of 68 amino acid residues. RANTES is a strong chemotractant for monocytes, NK cells, T cells, and eosinphils. RANTES may have important role in mediating immune and inflammatory responses.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Human
Reported Reactivity
Rhesus
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA)
Preparation
The antibody was purified by affinity chromatography and conjugated with PE under optimal conditions.
Concentration
Lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

ICFC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by intracellular immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µl per million cells in 100 µl staining volume or 5 µl per 100 µl of whole blood.

Excitation Laser
Blue Laser (488 nm)
Green Laser (532 nm)/Yellow-Green Laser (561 nm)
Application References

(PubMed link indicates BioLegend citation)
  1. Krensky AM, et al. 1997. Methods Enzymol. 287:162.
Product Citations
  1. McMurray JL, et al. 2022. Cell Rep. 39:110858. PubMed
RRID
AB_2561327 (BioLegend Cat. No. 515503)
AB_2561327 (BioLegend Cat. No. 515504)

Antigen Details

Structure
Human RANTES cDNA is a member of the C-C chemokine family with a MW of around 8 kD. Human and mouse RANTES have 85% homology.
Distribution

Reported to be produced by T cells, platelets, synovial fibroblasts, and some tumor cells.

Function
Able to chemoattract monocytes, NK cells, eosinophils, and T cells.
Interaction
Monocytes, NK cells, T cells, and eosinophils.
Cell Type
Fibroblasts, Platelets, T cells
Biology Area
Cell Biology, Immunology, Innate Immunity, Neuroinflammation, Neuroscience
Molecular Family
Cytokines/Chemokines
Antigen References

1. Von Luettichau. et al. 1996. Cytokine 8:89.
2. Schall TJ. 1991. Cytokine 3:165.

Gene ID
20304 View all products for this Gene ID
UniProt
View information about RANTES on UniProt.org

Related FAQs

What type of PE do you use in your conjugates?
We use R-PE in our conjugates.
Go To Top Version: 2    Revision Date: 01/13/2014

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account