PerCP/Cyanine5.5 anti-Pan-Cytokeratin

Pricing & Availability
Clone
AE-1/AE-3 (See other available formats)
Regulatory Status
RUO
Other Names
Pan-Cytokeratin (AE-1/AE-3), AE1/AE3
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
A.
AE-1-AE-3_Percp-Cya55_Pan_ICFC-1_072924
MCF-7 cells (positive cell line, solid histogram) were fixed and permeabilized using Cyto-Fast™ Fix/Perm Buffer Set (Cat. No. 426803) and intracellularly stained with PerCP/Cyanine5.5 anti-Pan-Cytokeratin (clone AE-1/AE-3) or PerCP/Cyanine5.5 mouse IgG1, κ isotype control (negative control, dashed histogram) (Cat No. 400149).
  • A.
AE-1-AE-3_Percp-Cya55_Pan_ICFC-1_072924
    MCF-7 cells (positive cell line, solid histogram) were fixed and permeabilized using Cyto-Fast™ Fix/Perm Buffer Set (Cat. No. 426803) and intracellularly stained with PerCP/Cyanine5.5 anti-Pan-Cytokeratin (clone AE-1/AE-3) or PerCP/Cyanine5.5 mouse IgG1, κ isotype control (negative control, dashed histogram) (Cat No. 400149).
  • B.
AE-1-AE-3_Percp-Cya55_Pan_ICFC_072924
    Jurkat cells (negative cell line, solid histogram) were fixed and permeabilized using Cyto-Fast™ Fix/Perm Buffer Set (Cat. No. 426803) and intracellularly stained with PerCP/Cyanine5.5 anti-Pan-Cytokeratin (clone AE-1/AE-3) or PerCP/Cyanine5.5 mouse IgG1, κ isotype control (dashed histogram) (Cat No. 400149).
  • C.AE-1-AE-3_PerCPCyaanine55_Cytokeratin_Antibody_3_101024
    Multiplexed IHC staining of PerCP/Cyanine5.5 anti-Pan-Cytokeratin (clone AE1/AE3) on formalin-fixed paraffin-embedded human tonsil tissue, validated for use on the Cellscape™. The tissue was iteratively stained with PerCP/Cyanine5.5 anti-panCytokeratin (clone AE1/AE3, green) and PerCP/Cyanine5.5 anti-CD45 (Cat. No. 368504, red) for one hour at room temperature. Nuclei were counterstained with Hoechst 33342. Images were captured with a 20X objective. Scale bar: 50 µm
Compare all formats See PerCP/Cyanine5.5 spectral data
Cat # Size Price Save
914209 25 tests ¥39,600
914210 100 tests ¥99,000
Description

AE-1 immunoreacts with an antigenic determinant present on most of the subfamily A cytokeratins, including cytokeratins with molecular weights of 56.5, 50, 48 and 40 kD. AE-3 reacts with an antigenic determinant shared by the subfamily B cytokeratins including cytokeratins with molecular weights of of 64, 59, 58, 56, and 52 kD.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Human, Rat
Reported Reactivity
Dog, Non-Human Primate
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
This antibody was developed using human epidermal keratins.
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA)
Preparation
The antibody was purified by affinity chromatography and conjugated with PerCP/Cyanine5.5 under optimal conditions.
Concentration
Lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

ICFC - Quality tested
SB - Community Verified

Recommended Usage

Each lot of this antibody is quality control tested by intracellular immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

* PerCP/Cyanine5.5 has a maximum absorption of 482 nm and a maximum emission of 690 nm. 

Excitation Laser
Blue Laser (488 nm)
Additional Product Notes

For use of this antibody in intracellular flow cytometry (ICFC), fixation/permeabilization using Cyto-Fast™ Fix/Perm Buffer Set (Cat. No. 426803) is recommended.

For the use of this antibody in spatial biology (SB), we have partnered with Bruker Spatial Biology Biosciences for demonstration of this antibody on their next-generation ChipCytometry instrument called the CellScape™. The CellScape platform is an end-to-end solution for highly multiplexed spatial omics. Combining an advanced, purpose-built imaging system with easy-to-use fluidics for walk-away automation, the CellScape system will accelerate your exploration into the rapidly evolving field of spatial biology. More information on the the Bruker Spatial Biology CellScape and a complete list of our antibodies that have been demonstrated on the instrument can be found here.

RRID
AB_3662341 (BioLegend Cat. No. 914209)
AB_3662341 (BioLegend Cat. No. 914210)

Antigen Details

Biology Area
Cell Biology, Cell Motility/Cytoskeleton/Structure, Neuroscience, Neuroscience Cell Markers
Molecular Family
Intermediate Filaments
Gene ID
NA
UniProt
View information about Pan-Cytokeratin on UniProt.org

Related FAQs

How stable is PerCP/Cyanine5.5 tandem as compared to PerCP alone?

PerCP/Cyanine5.5 is quite photostable and also better than PerCP alone in withstanding fixation.

If an antibody clone has been previously successfully used in IBEX in one fluorescent format, will other antibody formats work as well?

It’s likely that other fluorophore conjugates to the same antibody clone will also be compatible with IBEX using the same sample fixation procedure. Ultimately a directly conjugated antibody’s utility in fluorescent imaging and IBEX may be specific to the sample and microscope being used in the experiment. Some antibody clone conjugates may perform better than others due to performance differences in non-specific binding, fluorophore brightness, and other biochemical properties unique to that conjugate.

Will antibodies my lab is already using for fluorescent or chromogenic IHC work in IBEX?

Fundamentally, IBEX as a technique that works much in the same way as single antibody panels or single marker IF/IHC. If you’re already successfully using an antibody clone on a sample of interest, it is likely that clone will have utility in IBEX. It is expected some optimization and testing of different antibody fluorophore conjugates will be required to find a suitable format; however, legacy microscopy techniques like chromogenic IHC on fixed or frozen tissue is an excellent place to start looking for useful antibodies.

Are other fluorophores compatible with IBEX?

Over 18 fluorescent formats have been screened for use in IBEX, however, it is likely that other fluorophores are able to be rapidly bleached in IBEX. If a fluorophore format is already suitable for your imaging platform it can be tested for compatibility in IBEX.

The same antibody works in one tissue type but not another. What is happening?

Differences in tissue properties may impact both the ability of an antibody to bind its target specifically and impact the ability of a specific fluorophore conjugate to overcome the background fluorescent signal in a given tissue. Secondary stains, as well as testing multiple fluorescent conjugates of the same clone, may help to troubleshoot challenging targets or tissues. Using a reference control tissue may also give confidence in the specificity of your staining.

How can I be sure the staining I’m seeing in my tissue is real?

In general, best practices for validating an antibody in traditional chromogenic or fluorescent IHC are applicable to IBEX. Please reference the Nature Methods review on antibody based multiplexed imaging for resources on validating antibodies for IBEX.

Go To Top Version: 2    Revision Date: 10/10/2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account