Ultra-LEAF™ Purified anti-mouse CD48 Antibody

Pricing & Availability
Clone
HM48-1 (See other available formats)
Regulatory Status
RUO
Other Names
BCM1, SLAMF2, Blast-1
Isotype
Armenian Hamster IgG
Ave. Rating
Submit a Review
Product Citations
publications
C57BL/6 mouse splenocytes stained with Ultra-LEAF™ purified HM48-1, followed by anti-Armennian hamster IgG FITC
  • C57BL/6 mouse splenocytes stained with Ultra-LEAF™ purified HM48-1, followed by anti-Armennian hamster IgG FITC
Compare all formats
Cat # Size Price Save
103452 1 mg ¥24,740
103453 5 mg ¥89,480
103454 25 mg ¥233,730
103455 50 mg ¥390,770
103456 100 mg ¥561,580

Select size of product is eligible for a 40% discount! Promotion valid until December 31, 2024. Exclusions apply. To view full promotion terms and conditions or to contact your local BioLegend representative to receive a quote, visit our webpage.

Description

CD48 is a 45 kD GPI-anchored glycoprotein also known as BCM1, Blast-1 (human), and OX-45 (rat). It is a member of the Ig superfamily, expressed on T and B cells and monocytes/macrophages. It plays a role in adhesion and T cell recognition. The primary ligands for CD48 are CD2 and CD244.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Armenian Hamster
Immunogen
Mouse T lymphoma MBL-2
Formulation
0.2 µm filtered in phosphate-buffered solution, pH 7.2, containing no preservative.
Endotoxin Level
Less than 0.01 EU/µg of the protein (< 0.001 ng/µg of the protein) as determined by the LAL test.
Concentration
The antibody is bottled at the concentration indicated on the vial, typically between 2 mg/mL and 3 mg/mL. Older lots may have also been bottled at 1 mg/mL. To obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C. This Ultra-LEAF™ solution contains no preservative; handle under aseptic conditions.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.25 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application.

Application Notes

The HM48-1 antibody is useful for blocking in vitro and in vivo CD48 mediated interactions. Additional reported applications (for the relevant formats) include: immunoprecipitation1, costimulation of T cell proliferation1,2, blocking of CD48-CD2 interaction1, and inhibition of CTL activity and graft rejection1,2. For in vivo studies or highly sensitive assays, we recommend Ultra-LEAF™ purified antibody (Cat. Nos. 103452-103456) with a lower endotoxin limit (Endotoxin < 0.01 EU/µg).

Application References

(PubMed link indicates BioLegend citation)
  1. Kato K, et al. 1992. J. Exp. Med. 176:1241. (IP, Costim, Block)
  2. Qin L, et al. 1994. J. Exp. Med. 179:341. (Costim, Block)
RRID
AB_2832308 (BioLegend Cat. No. 103452)
AB_2832308 (BioLegend Cat. No. 103453)
AB_2832308 (BioLegend Cat. No. 103454)
AB_2832308 (BioLegend Cat. No. 103455)
AB_2832308 (BioLegend Cat. No. 103456)

Antigen Details

Structure
Ig superfamily, 45 kD
Distribution

T cells and B cells, monocytes/macrophages

Function
Adhesion, T cell recognition
Ligand/Receptor
CD2, CD244
Cell Type
B cells, Macrophages, Monocytes, T cells
Biology Area
Immunology
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References

1. Barclay AN, et al. 1997. The Leukocyte Antigen FactsBook Academic Press.
2. Flament C, et al. 1996. Hum. Immunol. 46:82.
3. Van der Merwe PA, et al. 1995. Curr. Biol. 5:74.
4. Latchman Y, et al. 1998. J. Immunol. 161:5809.

Gene ID
12506 View all products for this Gene ID
UniProt
View information about CD48 on UniProt.org

Related FAQs

Do you guarantee that your antibodies are totally pathogen free?

BioLegend does not test for pathogens in-house aside from the GoInVivo™ product line. However, upon request, this can be tested on a custom basis with an outside, independent laboratory.

Does BioLegend test each Ultra-LEAF™ antibody by functional assay?

No, BioLegend does not test Ultra-LEAF™ antibodies by functional assays unless otherwise indicated. Due to the possible complexities and variations of uses of biofunctional antibodies in different assays and because of the large product portfolio, BioLegend does not currently perform functional assays as a routine QC for the antibodies. However, we do provide references in which the antibodies were used for functional assays and we do perform QC to verify the specificity and quality of the antibody based on our strict specification criteria.

Does BioLegend test each Ultra-LEAF™ antibody for potential pathogens?

No, BioLegend does not test for pathogens in-house unless otherwise indicated.  However, we can recommend an outside vendor to perform this testing as needed.

Have you tested this Ultra-LEAF™ antibody for in vivo or in vitro applications?

We don't test our antibodies for in vivo or in vitro applications unless otherwise indicated. Depending on the product, the TDS may describe literature supporting usage of a particular product for bioassay. It may be best to further consult the literature to find clone specific information.

Go To Top Version: 1    Revision Date: 02/27/2020

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account