Purified anti-human CD183 (CXCR3) (Maxpar® Ready) Antibody

Pricing & Availability
Clone
G025H7 (See other available formats)
Regulatory Status
RUO
Other Names
CXCR3, G protein-coupled receptor 9 (GPR9), CKR-L2
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
G025H7_Purified_CD183_Cytof_060314.jpg
Human PBMCs stained with 170Er-anti-CD3 (UCHT1) and 156Gd-anti-CD183 (G025H7). Lymphocytes are displayed in the analysis. Data provided by DVS Sciences.
  • G025H7_Purified_CD183_Cytof_060314.jpg
    Human PBMCs stained with 170Er-anti-CD3 (UCHT1) and 156Gd-anti-CD183 (G025H7). Lymphocytes are displayed in the analysis. Data provided by DVS Sciences.
Compare all formats
Cat # Size Price Quantity Check Availability Save
353733 100 µg 193€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Human CXCR3, also known as GPR9, is a chemokine receptor that binds CXCL9, CXCL10, and CXCL11. It is a 38 kD seven-pass transmembrane receptor coupled to G-protein. CXCR3 is highly expressed by T cells (Th1), natural killer cells (NK cells), dendritic cells, mast cells, alveolar macrophages, eosinophils, and human airway epithelial cells. CXCR3 is important for effector lymphocyte recruitment into inflamed tissue in various inflammatory and autoimmune diseases, such as chronically inflamed liver, Crohn's disease, rheumatoid arthritis, multiple sclerosis, and inflammatory skin diseases.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human, Cynomolgus, Rhesus
Reported Reactivity
African Green, Baboon
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Human CXCR3 transfectants
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and EDTA.
Preparation
The antibody was purified by affinity chromatography.
Concentration
1.0 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C.
Application

FC - Quality tested
CyTOF® - Verified

Recommended Usage

This product is suitable for use with the Maxpar® Metal Labeling Kits. For metal labeling using Maxpar® Ready antibodies, proceed directly to the step to Partially Reduce the Antibody by adding 100 µl of Maxpar® Ready antibody to 100 µl of 4 mM TCEP-R in a 50 kDa filter and continue with the protocol. Always refer to the latest version of Maxpar® User Guide when conjugating Maxpar® Ready antibodies.

Additional Product Notes

Maxpar® is a registered trademark of Standard BioTools Inc.

Product Citations
  1. Roussel M, et al. 2021. Cell Reports Medicine. 2(6):100291. PubMed
  2. Jordan S, et al. 2020. Cell. 178(5):1102-1114.e17.. PubMed
RRID
AB_2563724 (BioLegend Cat. No. 353733)

Antigen Details

Structure
CXC-chemokine receptor, G protein-coupled receptor, seven-pass transmembrane receptor
Distribution

T cell subset, NK cells, plasmacytoid dendritic cells, GM-CSF activated CD34+ hematopoietic progenitors, mast cells, alveolar macrophages, eosinophils, and airway epithelial cells

Function
Essential in T cell recruitment to sites of inflammation
Ligand/Receptor
CXCL9, CXCL10, and CXCL11
Cell Type
Dendritic cells, Eosinophils, Epithelial cells, Hematopoietic stem and progenitors, Macrophages, Mast cells, NK cells, T cells, Tregs
Biology Area
Cell Biology, Immunology, Neuroinflammation, Neuroscience
Molecular Family
CD Molecules, Cytokine/Chemokine Receptors, GPCR
Antigen References

1. Loetscher M, et al. 1996. J. Exp. Med. 184:963.
2. Cole KE, et al. 1998. J. Exp. Med. 187:2009.
3. Aksoy MO, et al. 2006. Am. J. Physiol. Lung Cell Mol. Physiol. 290:L909.
4. Curbishley SM, et al. 2005. Am. J. Pathol. 167:887.
5. Turner JE, et al. 2007. Mini. Rev. Med. Chem. 7:1089.
6. Wenzel J, et al. 2008. J. Invest. Dermatol. 128:67.

Gene ID
2833 View all products for this Gene ID
UniProt
View information about CD183 on UniProt.org

Related FAQs

Does staining at room temperature or even at 37°C help for checking chemokine receptors expression?

Due to continuous recycling of many chemokine receptors, it may be worthwhile to consider staining at room temperature or at 37°C if the staining at lower temperature (which can potentially reduce receptor turnover) is not optimal.

Can I obtain CyTOF data related to your Maxpar® Ready antibody clones?

We do not test our antibodies by mass cytometry or on a CyTOF machine in-house. The data displayed on our website is provided by Fluidigm®. Please contact Fluidigm® directly for additional data and further details.

http://techsupport.fluidigm.com/

Can I use Maxpar® Ready format clones for flow cytometry staining?

We have not tested the Maxpar® Ready antibodies formulated in solution containing EDTA for flow cytometry staining. While it is likely that this will work in majority of the situations, it is best to use the non-EDTA formulated version of the same clone for flow cytometry testing. The presence of EDTA in some situations might negatively affect staining.

I am having difficulty observing a signal after conjugating a metal tag to your Maxpar® antibody. Please help troubleshoot.

We only supply the antibody and not test that in house. Please contact Fluidigm® directly for troubleshooting advice: http://techsupport.fluidigm.com/

Is there a difference between buffer formulations related to Maxpar® Ready and purified format antibodies?

The Maxpar® Ready format antibody clones are formulated in Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and EDTA. The regular purified format clones are formulated in solution that does not contain any EDTA. Both formulations are however without any extra carrier proteins.

Other Formats

View All CD183 Reagents Request Custom Conjugation
Description Clone Applications
Purified anti-human CD183 (CXCR3) G025H7 FC
APC/Cyanine7 anti-human CD183 (CXCR3) G025H7 FC
FITC anti-human CD183 (CXCR3) G025H7 FC
PE anti-human CD183 (CXCR3) G025H7 FC
APC anti-human CD183 (CXCR3) G025H7 FC
Alexa Fluor® 488 anti-human CD183 (CXCR3) G025H7 FC
Alexa Fluor® 647 anti-human CD183 (CXCR3) G025H7 FC
PerCP/Cyanine5.5 anti-human CD183 (CXCR3) G025H7 FC
Brilliant Violet 421™ anti-human CD183 (CXCR3) G025H7 FC
PE/Cyanine7 anti-human CD183 (CXCR3) G025H7 FC
Pacific Blue™ anti-human CD183 (CXCR3) G025H7 FC
Brilliant Violet 510™ anti-human CD183 (CXCR3) G025H7 FC
Brilliant Violet 605™ anti-human CD183 (CXCR3) G025H7 FC
Brilliant Violet 650™ anti-human CD183 (CXCR3) G025H7 FC
Brilliant Violet 711™ anti-human CD183 (CXCR3) G025H7 FC
Purified anti-human CD183 (CXCR3) (Maxpar® Ready) G025H7 FC,CyTOF®
PE/Dazzle™ 594 anti-human CD183 (CXCR3) G025H7 FC
PerCP anti-human CD183 (CXCR3) G025H7 FC
Brilliant Violet 785™ anti-human CD183 (CXCR3) G025H7 FC
Alexa Fluor® 700 anti-human CD183 (CXCR3) G025H7 FC
Biotin anti-human CD183 (CXCR3) G025H7 FC
TotalSeq™-A0140 anti-human CD183 (CXCR3) G025H7 PG
TotalSeq™-C0140 anti-human CD183 (CXCR3) G025H7 PG
Ultra-LEAF™ Purified anti-human CD183 (CXCR3) G025H7 Block,FC
TotalSeq™-B0140 anti-human CD183 (CXCR3) G025H7 PG
APC/Fire™ 750 anti-human CD183 (CXCR3) G025H7 FC
TotalSeq™-D0140 anti-human CD183 (CXCR3) G025H7 PG
PE/Fire™ 810 anti-human CD183 (CXCR3) Antibody G025H7 FC
APC/Fire™ 810 anti-human CD183 (CXCR3) Antibody G025H7 FC
PE/Cyanine5 anti-human CD183 (CXCR3) Antibody G025H7 FC
PE/Fire™ 640 anti-human CD183 (CXCR3) G025H7 FC
PerCP/Fire™ 780 anti-human CD183 (CXCR3) G025H7 FC
Spark Red™ 718 anti-human CD183 (CXCR3) (Flexi-Fluor™) G025H7 FC
PE/Fire™ 700 anti-human CD183 (CXCR3) G025H7 FC
PerCP/Fire™ 806 anti-human CD183 (CXCR3) G025H7 FC
PE anti-human CD183 G025H7 FC
Go To Top Version: 2    Revision Date: 07/22/2022

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account