Purified anti-mouse Slc7a1 (Cat-1, ERR) Antibody

Pricing & Availability
Clone
SA191A10 (See other available formats)
Regulatory Status
RUO
Other Names
Slc7a1, MLV, ERR, Ecotropic Retroviral Receptor, Cat1, hCat-1
Isotype
Rat IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
SA191A10_PURE_Slc7a1_FC_093015
C57BL/6 mouse splenocytes were stained with Slc7a1 (clone SA191A10) purified (filled histogram) or rat IgG2a, κ purified (open histogram), followed by anti-rat IgG2a PE.
  • SA191A10_PURE_Slc7a1_FC_093015
    C57BL/6 mouse splenocytes were stained with Slc7a1 (clone SA191A10) purified (filled histogram) or rat IgG2a, κ purified (open histogram), followed by anti-rat IgG2a PE.
Compare all formats
Cat # Size Price Quantity Check Availability Save
150502 100 µg 259€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Slc7a1, also known as Cat-1, is a 63 kD receptor that is associated with the transport of cationic amino acids. Slc7a1 is targeted for gene transduction in mouse cells using retroviral vectors. Slc7a1 is found in most cell types, but is not expressed in hepatic cells.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Mouse mCat-1 transfectants.
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography.
Concentration
0.5 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤0.5 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Product Citations
  1. Dominguez-Molina B, et al. 2019. Front Immunol. 9:2897. PubMed
RRID
AB_2565998 (BioLegend Cat. No. 150502)

Antigen Details

Structure
63 kD.
Distribution
T-cells, endothelial cells, glial cells, and is not expressed in hepatic cells.
Function
Transport of cationic amino acids.
Ligand/Receptor
Ecotropic murine leukemia virus, cationic amino acids.
Cell Type
T cells, Endothelial cells
Biology Area
Immunology
Antigen References

1. Wang X, et al. 2014. Biol. Reprod. 91:59.
2. Vina-Vilaseca A, et al. 2011. J. Biol. Chem. 10:8697.
3. Albritton LM, et al. 1989. Cell 57:659.
4. Kim JW, et al. 1991. Nature 352:725.

Gene ID
11987 View all products for this Gene ID
UniProt
View information about Slc7a1 on UniProt.org

Related FAQs

There are no FAQs for this product.
Go To Top Version: 1    Revision Date: 10/09/2015

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account