Ultra-LEAF™ Purified anti-human CD197 (CCR7) Antibody

Pricing & Availability
Clone
G043H7 (See other available formats)
Regulatory Status
RUO
Other Names
BLR2, CDw197, EBI1, CMKBR7
Isotype
Mouse IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
Chemotaxis of human CCR7-transfected BaF3 cells was performed in the presence of 15 ng/ml of recombinant CCL19. Addition of LEAF™ purified anti-human CCR7 (clone G043H7) inhibited migration of hCCR7 transfected BaF3 cells (ED 1.42 µg/ml).
  • Chemotaxis of human CCR7-transfected BaF3 cells was performed in the presence of 15 ng/ml of recombinant CCL19. Addition of LEAF™ purified anti-human CCR7 (clone G043H7) inhibited migration of hCCR7 transfected BaF3 cells (ED 1.42 µg/ml).
Compare all formats
Cat # Size Price Quantity Check Availability Save
353255 100 µg 190€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
353256 1 mg 551€
Check Availability


Need larger quantities of this item?
Request Bulk Quote

Select size of product is eligible for a 40% discount! Promotion valid until December 31, 2024. Exclusions apply. To view full promotion terms and conditions or to contact your local BioLegend representative to receive a quote, visit our webpage.

Description

CCR7, also known as CD197, is a chemokine receptor that binds CCL19 and CCL21. CCR7 and its ligands link innate and adaptive immunity by affecting interactions between T cells and dendritic cells and their downstream effect. Naïve T cells enter the lymph node through high endothelial venules, which express CCL21. Dendritic cells and macrophages enter the lymph node through afferent lymphatics. The encounter of T cells and dendritic cells in the T cell zone is CCR7-dependent. In addition, during immunological surveillance, B cells recirculate between B-cell-rich compartments (follicles or B cell zones) in secondary lymphoid organs, surveying for antigen. After antigen binding, B cells move to the boundary of B and T zones to interact with T-helper cells; this B cell migration is directed by CCR7 and its ligands. CCR7-positive cancer cell expression has been associated with lymph node metastasis.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Reported Reactivity
African Green, Baboon, Cynomolgus, Rhesus
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
CCR7-transfected cells
Formulation
0.2 µm filtered in phosphate-buffered solution, pH 7.2, containing no preservative.
Endotoxin Level
Less than 0.01 EU/µg of the protein (< 0.001 ng/µg of the protein) as determined by the LAL test.
Preparation
The Ultra-LEAF™ (Low Endotoxin, Azide-Free) antibody was purified by affinity chromatography.
Concentration
The antibody is bottled at the concentration indicated on the vial, typically between 2 mg/mL and 3 mg/mL. Older lots may have also been bottled at 1 mg/mL. To obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C. This Ultra-LEAF™ solution contains no preservative; handle under aseptic conditions.
Application

FC, Block - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.5 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Product Citations
  1. Chan S, et al. 2022. Nat Cancer. . PubMed
  2. Taft J, et al. 2021. Cell. 184(17):4447-4463.e20. PubMed
  3. Gruber CN, et al. 2020. Immunity. 53(3):672-684. PubMed
  4. Yang R, et al. 2020. Cell. 183(7):1826-1847.e31. PubMed
RRID
AB_2814290 (BioLegend Cat. No. 353255)
AB_2814290 (BioLegend Cat. No. 353256)

Antigen Details

Structure
Chemokine receptor, G protein-coupled receptors (GPCR), seven transmembrane receptor.
Distribution

T cells, B cells, NK, dendritic cells.

Function
The chemokine receptor CCR7 plays a pivotal role in the homing of naïve T cells and regulatory T cells to secondary lymphoid organs, and the migration of dendritic cells into afferent lymphatic vessels.
Ligand/Receptor
CCL19 and CCL21.
Cell Type
B cells, Dendritic cells, NK cells, T cells
Biology Area
Immunology
Molecular Family
CD Molecules, Cytokine/Chemokine Receptors, GPCR
Antigen References

1. Yanagihara S, et al. 1998. J. Immunol. 161:3096.
2. Charo IF, et al. 2006. N. Engl. J. Med. 354:610.
3. Reif K, et al. 2002. Nature 416:94.
4. Nakata B, et al. 2008. Oncology 74:69.
5. Brodie T. et al. 2013. Cytometry A. 6: 530-2. PubMed
6. Graves A.J. et al. 2014. Cytometry A. 7: 576–9 PubMed
7. Moncunill G. et al. 2014. Cytometry A. 12: 995-8 PubMed

Gene ID
1236 View all products for this Gene ID
UniProt
View information about CD197 on UniProt.org

Related FAQs

Does staining at room temperature or even at 37°C help for checking chemokine receptors expression?

Due to continuous recycling of many chemokine receptors, it may be worthwhile to consider staining at room temperature or at 37°C if the staining at lower temperature (which can potentially reduce receptor turnover) is not optimal.

Do you guarantee that your antibodies are totally pathogen free?

BioLegend does not test for pathogens in-house aside from the GoInVivo™ product line. However, upon request, this can be tested on a custom basis with an outside, independent laboratory.

Does BioLegend test each Ultra-LEAF™ antibody by functional assay?

No, BioLegend does not test Ultra-LEAF™ antibodies by functional assays unless otherwise indicated. Due to the possible complexities and variations of uses of biofunctional antibodies in different assays and because of the large product portfolio, BioLegend does not currently perform functional assays as a routine QC for the antibodies. However, we do provide references in which the antibodies were used for functional assays and we do perform QC to verify the specificity and quality of the antibody based on our strict specification criteria.

Does BioLegend test each Ultra-LEAF™ antibody for potential pathogens?

No, BioLegend does not test for pathogens in-house unless otherwise indicated.  However, we can recommend an outside vendor to perform this testing as needed.

Have you tested this Ultra-LEAF™ antibody for in vivo or in vitro applications?

We don't test our antibodies for in vivo or in vitro applications unless otherwise indicated. Depending on the product, the TDS may describe literature supporting usage of a particular product for bioassay. It may be best to further consult the literature to find clone specific information.

Other Formats

View All CD197 Reagents Request Custom Conjugation
Description Clone Applications
Purified anti-human CD197 (CCR7) G043H7 FC
Alexa Fluor® 488 anti-human CD197 (CCR7) G043H7 FC
Brilliant Violet 421™ anti-human CD197 (CCR7) G043H7 FC
PE anti-human CD197 (CCR7) G043H7 FC
APC/Cyanine7 anti-human CD197 (CCR7) G043H7 FC
Pacific Blue™ anti-human CD197 (CCR7) G043H7 FC
APC anti-human CD197 (CCR7) G043H7 FC
FITC anti-human CD197 (CCR7) G043H7 FC
Alexa Fluor® 647 anti-human CD197 (CCR7) G043H7 FC
PerCP/Cyanine5.5 anti-human CD197 (CCR7) G043H7 FC
Brilliant Violet 605™ anti-human CD197 (CCR7) G043H7 FC
PE/Cyanine7 anti-human CD197 (CCR7) G043H7 FC
Brilliant Violet 711™ anti-human CD197 (CCR7) G043H7 FC
Brilliant Violet 785™ anti-human CD197 (CCR7) G043H7 FC
Brilliant Violet 510™ anti-human CD197 (CCR7) G043H7 FC
Brilliant Violet 650™ anti-human CD197 (CCR7) G043H7 FC
PE/Dazzle™ 594 anti-human CD197 (CCR7) G043H7 FC
Biotin anti-human CD197 (CCR7) G043H7 FC
Purified anti-human CD197 (CCR7) (Maxpar® Ready) G043H7 FC,CyTOF®
PerCP anti-human CD197 (CCR7) G043H7 FC
Alexa Fluor® 700 anti-human CD197 (CCR7) G043H7 FC
APC/Fire™ 750 anti-human CD197 (CCR7) G043H7 FC
TotalSeq™-A0148 anti-human CD197 (CCR7) G043H7 PG
TotalSeq™-B0148 anti-human CD197 (CCR7) G043H7 PG
TotalSeq™-C0148 anti-human CD197 (CCR7) G043H7 PG
Brilliant Violet 750™ anti-human CD197 (CCR7) G043H7 FC
Ultra-LEAF™ Purified anti-human CD197 (CCR7) G043H7 FC,Block
Spark NIR™ 685 anti-human CD197 (CCR7) G043H7 FC
KIRAVIA Blue 520™ anti-human CD197 (CCR7) G043H7 FC
PE/Fire™ 640 anti-human CD197 (CCR7) G043H7 FC
Spark YG™ 581 anti-human CD197 (CCR7) G043H7 FC
APC/Fire™ 810 anti-human CD197 (CCR7) Antibody G043H7 FC
TotalSeq™-D0148 anti-human CD197 (CCR7) G043H7 PG
PE/Fire™ 810 anti-human CD197 (CCR7) Antibody G043H7 FC
PE/Cyanine5 anti-human CD197 (CCR7) G043H7 FC
Spark YG™ 593 anti-human CD197 (CCR7) G043H7 FC
PE/Fire™ 744 anti-human CD197 (CCR7) G043H7 FC
Spark Red™ 718 anti-human CD197 (CCR7) (Flexi-Fluor™) G043H7 FC
Spark Red™ 718 anti-human CD197 (CCR7) G043H7 FC
PE anti-human CD197 G043H7 FC
Spark PLUS UV395™ anti-human CD197 (CCR7) G043H7 FC
Go To Top Version: 1    Revision Date: 08/15/2019

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account