Alexa Fluor® 594 anti-Vimentin Antibody

Pricing & Availability
Clone
O91D3 (See other available formats)
Regulatory Status
RUO
Other Names
CTRCT30, HEL 113, Epididymis Luminal Protein 113
Isotype
Mouse IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
1_O91D3_A594_Vimentin_Antibody_1_102720
HeLa cells were fixed with 2% paraformaldehyde (PFA) for ten minutes and then were permeabilized with 0.5% Triton X-100 for five minutes followed by blocking with 5% FBS for 30 minutes. The cells were then intracellularly stained with 2.5 µg/ml Alexa Fluor® 594 anti-Vimentin antibody (clone O91D3) (red) in a blocking buffer overnight at 4°C, followed by Alexa Fluor® 488 phalloidin (green) staining for 20 minutes at room temperature. Nuclei were counterstained with DAPI (blue).
  • 1_O91D3_A594_Vimentin_Antibody_1_102720
    HeLa cells were fixed with 2% paraformaldehyde (PFA) for ten minutes and then were permeabilized with 0.5% Triton X-100 for five minutes followed by blocking with 5% FBS for 30 minutes. The cells were then intracellularly stained with 2.5 µg/ml Alexa Fluor® 594 anti-Vimentin antibody (clone O91D3) (red) in a blocking buffer overnight at 4°C, followed by Alexa Fluor® 488 phalloidin (green) staining for 20 minutes at room temperature. Nuclei were counterstained with DAPI (blue).
  • 2_O91D3_A594_Vimentin_Antibody_2_102720
    Human paraffin-embedded colon tissue slices were prepared with a standard protocol of deparaffination and rehydration. Antigen retrieval was done with Tris-Buffered Saline 20X (1.0M, pH7.4) (BioLegend, Cat number 925501) at 95°C for 40 minutes. Tissue was washed with PBS/ 0.05% Tween20 twice for 5 minutes , permeabilized with 0.5% Trito-X 100 for ten minutes and blocked with 5% FBS and 0.2% Gelatin for 30 minutes. Then, the tissue was stained with 5 µg/ml of anti-human vimentin (clone O91D3) Alexa Fluor® 594 (red) and Pan-Cytokeratin Alexa Fluor® 488 (green) at 4°C overnight. Nuclei were counterstained with DAPI (blue). The image was captured with a 10X objective.
  • 3_22_Human_LN_CD49a_Vimentin
    Confocal image of human lymph node sample acquired using the IBEX method of highly multiplexed antibody-based imaging: CD49a (green) in Cycle 2 and Vimentin (blue) in Cycle 6. Tissues were prepared using ~1% (vol/vol) formaldehyde and a detergent. Following fixation, samples are immersed in 30% (wt/vol) sucrose for cryoprotection. Images are courtesy of Drs. Andrea J. Radtke and Ronald N. Germain of the Center for Advanced Tissue Imaging (CAT-I) in the National Institute of Allergy and Infectious Diseases (NIAID, NIH).
  • 4_30_Human_Skin_CD117_CD138_Vimentin
    Confocal image of human skin sample acquired using the IBEX method of highly multiplexed antibody-based imaging: CD117 (magenta) in Cycle 3, CD138 (cyan) in Cycle 4, and Vimentin (blue) in Cycle 5. Tissues were prepared using ~1% (vol/vol) formaldehyde and a detergent. Following fixation, samples are immersed in 30% (wt/vol) sucrose for cryoprotection. Images are courtesy of Drs. Andrea J. Radtke and Ronald N. Germain of the Center for Advanced Tissue Imaging (CAT-I) in the National Institute of Allergy and Infectious Diseases (NIAID, NIH).
Compare all formats See Alexa Fluor® 594 spectral data
Cat # Size Price Quantity Check Availability Save
677804 100 µg 278€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Vimentin are class-III intermediate filaments found in various non-epithelial cells, especially mesenchymal cells. Vimentin is a widely expressed and highly conserved 54 kD protein that is constitutively expressed in mesenchymal cells, endothelial cells lining blood vessels, renal tubular cells, macrophages, neutrophils, fibroblasts, and leukocytes1,2. Vimentin is used as a marker of mesenchymal cells to distinguish them from epithelial cells3. Increased vimentin expression is frequently used as an EMT marker in cancer4. Autoantibodies to vimentin are commonly found in patients with autoimmune diseases such as Lupus5 and rheumatoid arthritis6, and also found after transplantation7.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Full length human vimentin produced in E. coli.
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography and conjugated with Alexa Fluor® 594 under optimal conditions.
Concentration
0.5 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

ICC - Quality tested
IHC-P - Verified
SB - Reported in the literature, not verified in house

Recommended Usage

Each lot of this antibody is quality control tested by immunocytochemistry. For immunocytochemistry, a concentration range of 0.1 - 10 μg per mL is recommended. For immunohistochemistry on formalin-fixed paraffin-embedded tissue sections, a concentration range of 5.0 - 10 µg/mL is suggested. It is recommended that the reagent be titrated for optimal performance for each application.

* Alexa Fluor® 594 has an excitation maximum of 590 nm, and a maximum emission of 617 nm.


Alexa Fluor® and Pacific Blue™ are trademarks of Life Technologies Corporation.

View full statement regarding label licenses
Excitation Laser
Green Laser (532 nm)/Yellow-Green Laser (561 nm)
Application Notes

While this clone recognizes mouse Vimentin, we do not recommend its usage for western blot due to poor affinity of the antibody for the protein. Additional reported applications for the relevant formats include: spatial biology (IBEX)1,2.

Additional Product Notes

Iterative Bleaching Extended multi-pleXity (IBEX) is a fluorescent imaging technique capable of highly-multiplexed spatial analysis. The method relies on cyclical bleaching of panels of fluorescent antibodies in order to image and analyze many markers over multiple cycles of staining, imaging, and, bleaching. It is a community-developed open-access method developed by the Center for Advanced Tissue Imaging (CAT-I) in the National Institute of Allergy and Infectious Diseases (NIAID, NIH).

Application References
  1. Radtke AJ, et al. 2020. Proc Natl Acad Sci USA. 117:33455-33465. (SB) PubMed
  2. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed
Product Citations
  1. Alzubi MA, et al. 2019. Breast Cancer Res. 21:36. PubMed
  2. Li J, et al. 2020. Elife. 9:00. PubMed
  3. Aboulkheyr Es H, et al. 2021. J Cell Physiol. 236:3918. PubMed
  4. Es HA, et al. 2021. Cancers (Basel). 13:. PubMed
RRID
AB_2566179 (BioLegend Cat. No. 677804)

Antigen Details

Structure
466 amino acids with a predicted molecular weight of approximately 54 kD.
Distribution

Cytoplasm.

Function
Vimentins are class-III intermediate filaments found in various non-epithelial cells, especially mesenchymal cells. Vimentin is attached to the nucleus, endoplasmic reticulum, and mitochondria, either laterally or terminally.
Interaction
HCV core protein, LGSN, SYNM, PLEC, SLC6A4, STK33, LARP6, RAB8B, TOR1A, TOR1AIP1, and BCAS3.
Cell Type
B cells, Mesenchymal Stem Cells, Neural Stem Cells, Neutrophils
Biology Area
Cell Adhesion, Cell Biology, Cell Motility/Cytoskeleton/Structure, Immunology, Neuroscience, Neuroscience Cell Markers, Stem Cells
Molecular Family
Intermediate Filaments
Antigen References

1. Kidd ME, et al. 2014. Am. J. Respir. Cell Mol. Biol. 50:1.
2. Fuchs E, et al. 1994. Annu. Rev. Biochem. 63:345.
3. Zeisberg M, et al. 2009. J. Clin. Invest. 119:1429.
4. Scanlon CS, et al. 2013. J. Dent. Res. 92:114.
5. Thebault S, et al. 2002. J. Immunol. 169:4046.
6. Vossenaar ER, et al. 2004. Arthritis Res. Ther. 6:R142.
7. Rose ML. 2013. Hum. Immunol. 74:1459.

Gene ID
7431 View all products for this Gene ID
UniProt
View information about Vimentin on UniProt.org

Related FAQs

If an antibody clone has been previously successfully used in IBEX in one fluorescent format, will other antibody formats work as well?

It’s likely that other fluorophore conjugates to the same antibody clone will also be compatible with IBEX using the same sample fixation procedure. Ultimately a directly conjugated antibody’s utility in fluorescent imaging and IBEX may be specific to the sample and microscope being used in the experiment. Some antibody clone conjugates may perform better than others due to performance differences in non-specific binding, fluorophore brightness, and other biochemical properties unique to that conjugate.

Will antibodies my lab is already using for fluorescent or chromogenic IHC work in IBEX?

Fundamentally, IBEX as a technique that works much in the same way as single antibody panels or single marker IF/IHC. If you’re already successfully using an antibody clone on a sample of interest, it is likely that clone will have utility in IBEX. It is expected some optimization and testing of different antibody fluorophore conjugates will be required to find a suitable format; however, legacy microscopy techniques like chromogenic IHC on fixed or frozen tissue is an excellent place to start looking for useful antibodies.

Are other fluorophores compatible with IBEX?

Over 18 fluorescent formats have been screened for use in IBEX, however, it is likely that other fluorophores are able to be rapidly bleached in IBEX. If a fluorophore format is already suitable for your imaging platform it can be tested for compatibility in IBEX.

The same antibody works in one tissue type but not another. What is happening?

Differences in tissue properties may impact both the ability of an antibody to bind its target specifically and impact the ability of a specific fluorophore conjugate to overcome the background fluorescent signal in a given tissue. Secondary stains, as well as testing multiple fluorescent conjugates of the same clone, may help to troubleshoot challenging targets or tissues. Using a reference control tissue may also give confidence in the specificity of your staining.

How can I be sure the staining I’m seeing in my tissue is real?

In general, best practices for validating an antibody in traditional chromogenic or fluorescent IHC are applicable to IBEX. Please reference the Nature Methods review on antibody based multiplexed imaging for resources on validating antibodies for IBEX.

Go To Top Version: 5    Revision Date: 06-10-2022

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account