APC/Fire™ 750 anti-mouse IgG1 Antibody

Pricing & Availability
Clone
RMG1-1 (See other available formats)
Regulatory Status
RUO
Other Names
Immunoglobulin G1
Isotype
Rat IgG
Ave. Rating
Submit a Review
Product Citations
publications
RMG1-1_APCFire750_IgG1_Antibody_081417
Human peripheral blood lymphocytes were stained with purified anti-human CD3 (clone UCHT1 isotype mouse IgG1, κ) followed by APC/Fire™ 750 anti-mouse IgG1 antibody (filled histogram) or APC/Fire™ 750 anti-mouse IgG1 antibody alone (open histogram).
  • RMG1-1_APCFire750_IgG1_Antibody_081417
    Human peripheral blood lymphocytes were stained with purified anti-human CD3 (clone UCHT1 isotype mouse IgG1, κ) followed by APC/Fire™ 750 anti-mouse IgG1 antibody (filled histogram) or APC/Fire™ 750 anti-mouse IgG1 antibody alone (open histogram).
Compare all formats See APC/Fire™ 750 spectral data
Cat # Size Price Quantity Check Availability Save
406623 25 µg 72€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
406624 100 µg 165€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

The RMG1-1 monoclonal antibody reacts with immunoglobulin G1 (IgG1) in all tested mouse haplotype (Igh-a and b). It does not react with other isotypes. The RMG1-1 monoclonal antibody may be used as a primary or secondary reagent for ELISA or immunofluorescent analysis.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Mouse Ig cocktail
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography and conjugated with APC/Fire™ 750 under optimal conditions.
Concentration
0.2 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤0.125 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application.

* APC/Fire™ 750 has a maximum excitation of 650 nm and a maximum emission of 774 nm.

Excitation Laser
Red Laser (633 nm)
Application References
  1. Rucci F, et al. 2010. P. Natl. Acad. Sci. USA 107:3024. (FC) PubMed
  2. Zhang JG, et al. 2011. Int. Immunopharmacol. 11:1685. PubMed
Product Citations
  1. Rabe DC, et al. 2021. Cancers (Basel). 13:. PubMed
RRID
AB_2715963 (BioLegend Cat. No. 406623)
AB_2715963 (BioLegend Cat. No. 406624)

Related FAQs

There are no FAQs for this product.
Go To Top Version: 0    Revision Date: 08-14-2017

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account