Brilliant Violet 421™ anti-human GM-CSF Antibody

Pricing & Availability
Clone
BVD2-21C11 (See other available formats)
Regulatory Status
RUO
Other Names
Granulocyte/macrophage colony-stimulating factor, CSF-α, Pluripoietin-α, Eosinophil colony stimulating factor (Eo-CSF), Burst promoting activity (BPA)
Isotype
Rat IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
BVD2-21C11_BV421_GM-CSF_Antibody_111423
PMA+ ionomycin stimulated (6 hours) human peripheral blood lymphocytes (in the presence of monensin) were surface stained with anti-human CD3 (clone UCHT1) PE. Cells were then fixed, permeabilized, then intracellularly stained with anti-human GM-CSF (clone BVD2-21C11) Brilliant Violet 421™ (left) or rat lgG2a, κ Brilliant Violet 421™ isotype control (right).
  • BVD2-21C11_BV421_GM-CSF_Antibody_111423
    PMA+ ionomycin stimulated (6 hours) human peripheral blood lymphocytes (in the presence of monensin) were surface stained with anti-human CD3 (clone UCHT1) PE. Cells were then fixed, permeabilized, then intracellularly stained with anti-human GM-CSF (clone BVD2-21C11) Brilliant Violet 421™ (left) or rat lgG2a, κ Brilliant Violet 421™ isotype control (right).
Compare all formats See Brilliant Violet 421™ spectral data
Cat # Size Price Quantity Check Availability Save
502323 25 tests 152€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
502324 100 tests 312€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Granulocyte/macrophage - colony stimulating factor (GM-CSF) is a hematopoietic factor that is produced by activated T cells, B cells, mast cells, macrophages, fibroblasts, and endothelial cells. In addition to supporting colony formation of granulocyte/macrophage progenitors, GM-CSF is a growth factor for erythroid, megakaryocyte, and eosinophil progenitors.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Reported Reactivity
Cynomolgus, Rhesus
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
E. coli-expressed, recombinant human GM-CSF.
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA)
Preparation
The antibody was purified by affinity chromatography and conjugated with Brilliant Violet 421™ under optimal conditions.
Concentration
Lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

ICFC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by intracellular immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

Brilliant Violet 421™ excites at 405 nm and emits at 421 nm. The standard bandpass filter 450/50 nm is recommended for detection. Brilliant Violet 421™ is a trademark of Sirigen Group Ltd.


Learn more about Brilliant Violet™.

This product is subject to proprietary rights of Sirigen Inc. and is made and sold under license from Sirigen Inc. The purchase of this product conveys to the buyer a non-transferable right to use the purchased product for research purposes only. This product may not be resold or incorporated in any manner into another product for resale. Any use for therapeutics or diagnostics is strictly prohibited. This product is covered by U.S. Patent(s), pending patent applications and foreign equivalents.
Excitation Laser
Violet Laser (405 nm)
Application Notes

Additional reported applications (for the relevant formats) include: ELISA1-4 or ELISPOT3,4 Detection, Neutralization1, immunohistochemical staining of paraformaldehyde-fixed, saponin-treated5,6 and acetone-fixed7 frozen tissue sections, and immunocytochemistry.

Note: For testing human GM-CSF in serum or plasma, BioLegend's ELISA Max™ Sets (Cat. No. 432001 to 432006) are specially developed and recommended.

Application References
  1. Abrams J, et al. 1992. Immunol. Rev. 127:5. (ELISA, Neut, IP)
  2. Abrams J, et al. 1994. Eosinophils in Allergy and Inflammation. Marcel Dekker New York. p.133. (ELISA)
  3. Bacchetta R, et al. 1990. J. Immunol. 144:902. (ELISA)
  4. Kita H, et al. 1991. J. Exp. Med. 174:745. (ELISA)
  5. Andersson U, et al. 1999. Detection and quantification of gene expression. New York:Springer-Verlag. (IHC)
  6. Andersson J, et al. 1994. Immunology 83:16. (IHC)
  7. Rasouli J, et al. 2015. J. Immunol. 11:5085-93. (IHC)
RRID
AB_3097305 (BioLegend Cat. No. 502323)
AB_3097305 (BioLegend Cat. No. 502324)

Antigen Details

Structure
Cytokine; 22 kD (Mammalian)
Bioactivity
Growth/development factor for granulocyte/macrophage progenitors; differentiates myeloblasts/monoblasts; synergizes with Epo proliferation of erythroid/megakaryocytic progenitors
Cell Sources
T cells, macrophages, fibroblasts, endothelial cells, mast cells
Cell Targets
Granulocyte/macrophage/erythroid/megakaryocytic progenitors, myeloblasts, monoblasts
Receptors
Heterodimer GM-CSFR α subunit (CDw116); β-subunit (CDw131), which is also shared with the IL-3 and IL-5 receptor α chains
Biology Area
Cell Biology, Stem Cells
Molecular Family
Cytokines/Chemokines, Growth Factors
Antigen References

1. Fitzgerald K, et al. Eds. 2001. The Cytokine FactsBook. Academic Press San Diego.
2. Demetri G, et al. 1991. Blood 78:2791.
3. Fan D, et al. 1991. In vivo 5:571.
4. Negrin R, et al. 1992. Adv. Pharmacol. 23:263.

Regulation
Synergistic with IL-1, IL-3, G-CSF; E21R competitive antagonist for receptor binding; stored in ECM with heparan sulfate proteoglycans
Gene ID
1437 View all products for this Gene ID
UniProt
View information about GM-CSF on UniProt.org

Related FAQs

What is the F/P ratio range of our BV421™ format antibody reagents?

It is lot-specific. On average it ranges between 2-4.

Other Formats

View All GM-CSF Reagents Request Custom Conjugation
Description Clone Applications
Biotin anti-human GM-CSF BVD2-21C11 ELISA Detection,ELISPOT Detection,ICFC
PE anti-human GM-CSF BVD2-21C11 ICFC
Purified anti-human GM-CSF BVD2-21C11 ELISA Capture,ICFC,IP,WB
PerCP/Cyanine5.5 anti-human GM-CSF BVD2-21C11 ICFC
APC anti-human GM-CSF BVD2-21C11 ICFC
Pacific Blue™ anti-human GM-CSF BVD2-21C11 ICFC
Purified anti-human GM-CSF (Maxpar® Ready) BVD2-21C11 ELISA Capture,CyTOF®
PE/Dazzle™ 594 anti-human GM-CSF BVD2-21C11 ICFC
Ultra-LEAF™ Purified anti-human GM-CSF BVD2-21C11 Neut
TotalSeq™-B0943 anti-human GM-CSF BVD2-21C11 ICPG
Brilliant Violet 421™ anti-human GM-CSF BVD2-21C11 ICFC
Go To Top Version: 1    Revision Date: 11-14-2023

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account