Compensation Beads

Pricing & Availability
Regulatory Status
RUO
Other Names
Compensation, Comp Beads
Ave. Rating
Submit a Review
Product Citations
publications
a_CompBead_ContentImage
Kit content image for the Compensation Beads
  • a_CompBead_ContentImage
    Kit content image for the Compensation Beads
  • b_Composition-Beads_Flow-Human_060322
    Compensation Beads were stained with 23 different FITC-conjugated isotypes of antibodies of mouse, rat, rabbit, donkey, hamster and human origin. Beads were stained with 0.05 µg of antibody per test.
Cat # Size Price Quantity Check Availability Save
424601 25 tests 82€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
424602 100 tests 188€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Compensation Beads can bind fluorescently tagged mouse, rat, rabbit, donkey, hamster and human antibodies. Each kit contains 1 dropper bottle of negative beads and 1 dropper bottle of positive beads. The positive beads will bind any mouse, rat, rabbit, donkey, hamster or human antibody. Antibodies from other host species have not been verified to bind to the positive beads. The negative beads will not bind any antibody. Compensation Beads can be used as compensation controls for multicolor flow cytometry assays.

Compensation Beads can be used for dyes excited by blue (488 nm), green (532 nm), yellow/green (561 nm), violet (405 nm), ultraviolet (355 nm), and red (633-635 nm) lasers.

Product Details
Technical Data Sheet (pdf)

Product Details

Formulation
Each kit will contain sets of two dropper bottles as listed below:

1. Negative beads
2. Positive beads
Preparation
Compensation Beads are supplied ready to use, 1 drop (~25-30 µL) from each bottle is sufficient for one test.
Storage & Handling
Store the kit at 2°C - 8°C upon receipt.
Application

FC - Quality tested

Recommended Usage

1 drop of positive beads plus one drop of negative beads

Application Notes

Compensation Beads can bind mouse, rat, rabbit, donkey, hamster and human monoclonal or polyclonal antibodies. Antibodies from other host species have not been verified to bind to the positive beads and may not be compatible for use with this product. Product is a kit of one positive beads bottle and one negative beads bottle. Compensation Beads can be used as compensation controls for multicolor flow cytometry assays or in any other assay that require antibody binding beads.

Protocol for using Compensation Beads:

  1. Vortex beads vigorously for 1-2 minutes prior to using to disrupt aggregates that may have formed during storage.
  2. Prepare tubes with appropriate antibodies (single color).
  3. Add one drop of beads from each bottle (positive and negative). Mix thoroughly. Ensure that any stray liquid on the side of the tube is mixed in with the antibody. 
  4. Incubate at room temperature for 15-20 minutes, protected from exposure to light.
  5. Wash beads with Cell Staining Buffer (Cat. No. 420201) or equivalent.  
  6. Centrifuge at 350Xg for 5 minutes and re-suspend in Cell Staining Buffer or equivalent.  Beads are ready to acquire.

Antigen Details

Gene ID
NA

Related FAQs

I observed multiple positive peaks when running Compensation Beads. What could be causing this?

Multiple positive peaks can occur from insufficient vortexing or mixing of compensation beads. Be sure to vigorously vortex beads for at least one minute before dispensing drops. Longer vortexing helps to disrupt aggregates that can form during storage. Also, ensure that any stray droplets sticking to the side of the tube are thoroughly mixed in with your sample before incubation. If you have already prepared your single-color controls and do not wish to remake them, try setting your positive gate on the major peak, excluding minor stained populations.

Go To Top Version: 2    Revision Date: 11-08-2023

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account