LEGENDplex™ Mouse B cell Panel - S/P (12-plex) w/VbP

Pricing & Availability
Regulatory Status
RUO
Other Names
IL-4, IL-6, IL-12p70, IL-17A, IL-2, TNF-α, TGF-β1 (Free Active Form), IL-13, IFN-γ, BCMA, sCD40L, IL-10
Ave. Rating
Submit a Review
Cat # Size Price Quantity Save
740827 100 tests 1316€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

The LEGENDplex™ Mouse B cell Panel (13-plex) is a bead-based multiplex assay panel, using fluorescence-encoded beads suitable for use on various flow cytometers. This panel focuses on 13 key biomarkers involved in B cell function, activation, and survival. It allows for simultaneous quantification of 13 mouse targets such as IL-4, IL-6, IL-12p70, IL-17A, IL-2, TNF-α, Free Active TGF-β1, IL-13, IFN-γ, BAFF, BCMA, sCD40L, and IL-10. This assay panel provides higher detection sensitivity and broader dynamic range than traditional ELISA methods. The panel has been validated for use on cell culture supernatant, serum, and plasma samples.

 

The LEGENDplex™ Mouse B cell Panel is configured as shown below depending on sample types and required dilutions:

 

Catalog

No.

Plex

Size

Targets

Recommended

Sample Type

Recommended

Dilution Factor

740818

740819

13-plex

IL-4, IL-6, IL-12p70, IL-17A, IL-2, TNF-α, Free Active TGF-β1, IL-13, IFN-γ, BAFF, BCMA, sCD40L, IL-10

Tissue Culture*

Varies

740826

740827

12-plex

IL-4, IL-6, IL-12p70, IL-17A, IL-2, TNF-α, Free Active TGF-β1, IL-13, IFN-γ, BCMA, sCD40L, IL-10

Serum, Plasma

2

Tissue Culture

Varies

740982

740983

1-plex

BAFF

Serum, Plasma

25

Tissue Culture

Varies

740824

740825

3-plex

IL-12p70, TNF-α, IFN-γ

Serum, Plasma

2

Tissue Culture

Varies

740822

740823

5-plex

IL-4, IL-6, IL-2, TNF-α, IL-13

Serum, Plasma

2

Tissue Culture

Varies

740820

740821

8-plex

IL-4, IL-6, IL-12p70, IL-17A, IL-2, TNF-α, IL-13, IFN-γ

Serum, Plasma

2

Tissue Culture

Varies

740828

740829

2-plex

Free Active TGF-β1, IL-10

Serum, Plasma

2

Tissue Culture

Varies

*Note: Serum and plasma are not the recommended sample type. Refer to Sample Dilution section in the manual for details.

 

The LEGENDplex™ Mouse B cell Panel is designed to allow flexible customization within the panel. Please visit www.biolegend.com/legendplex for more information on how to mix and match within the panel. This assay is for research use only.

Product Details
View Current Manual (pdf)

Kit Contents

Kit Contents
  • Setup Beads: PE Beads 
  • Setup Beads: Raw Beads 
  • Capture Beads 
  • Detection Antibodies 
  • Standard Cocktail, Lyophilized 
  • Matrix C1, Lyophilized 
  • SA-PE 
  • Assay Buffer 
  • Wash Buffer 
  • Plate Sealers 
  • V-bottom Plate

Product Details

Verified Reactivity
Mouse
Application

Multiplex


Learn more about LEGENDplex™ at biolegend.com/legendplex

Download the LEGENDplex™ software here.
Materials Not Included
  • Flow Cytometer
  • Pipettes and Tips
  • Reagent Reservoirs for Multichannel Pipettes
  • Polypropylene Microfuge Tubes
  • Vortex Mixer
  • Aluminum foil
  • Absorbent pads or paper towels
  • Sonicator
  • Plate Shaker
  • Tabletop centrifuge
  • 1.1 mL polypropylene micro FACS tubes, in 96-tube rack
  • A Vacuum Filtration Unit and a Vacuum Source (if using filter plates)
  • Manual

Related FAQs

If I don't have a vacuum, how do I remove the liquid from my plate?

If you do not have a vacuum, the assay should be run in a V-bottom plate. After centrifugation using a swinging-bucket rotor with a plate adaptor, you can remove the liquid by flicking the plate quickly, dumping the contents into a sink, and patting it dry carefully on a stack of clean paper towels without losing the beads. Alternatively, you can remove the liquid by using a pipette.

Should I perform the assay with the filter plates or with V-bottom plates?

Filter plates or V-bottom plates have been included in some kits for your convenience. A vacuum filtration unit is required to work with the filter plates. However, if you don’t have access to a vacuum manifold or if you prefer, then you can use the V-bottom plates and follow the recommended assay protocols for the type of plates you choose. All plates should be made from low binding polypropylene. Polystyrene ELISA or cell culture plates should not be used.

After I finish the staining process, how long can I wait before reading my LEGENDplex™ samples?

The samples can be kept overnight at 4°C while being protected from exposure to light and be read the next day. There may be a decrease in signal, but overall, the assay results should not be affected. Storing the samples for extended periods of time is not recommended, as it could lead to further reductions in signal.

What is the shelf life of LEGENDplex™ kits?

LEGENDplex™ kits are guaranteed for 6 months from the date of receipt, but may have a shelf life of up to 2 years from the date of manufacture.

Is special software required for data analysis?

Typically flow cytometers generate output files in FCS format (e.g. FCS 2.0, 3.0, or 3.1) and in some cases in list mode file format (LMD). Other software may be available to analyze FCS files. Data generated using LEGENDplex™ kits can be analyzed using the freely available LEGENDplex™ data analysis software. Please check our website for the most updated versions of the software.

Go To Top Version: 5    Revision Date: 01-12-2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587


Login / Register
Remember me
Forgot your password? Reset password?
Create an Account