Rainbow Fluorescent Particles, 1 peak (3.0-3.4 µm) - Bright Intensity

Pricing & Availability
Regulatory Status
RUO
Other Names
Sphero™ brand beads, 1 peak Rainbow Calibration Bead
Ave. Rating
Submit a Review
Product Citations
publications
RFP_1-peakBI_1_080812
Bead fluorescence at 405 nm excitation with a 450/50 BP filter (Pacific Blue™ channel).
  • RFP_1-peakBI_1_080812
    Bead fluorescence at 405 nm excitation with a 450/50 BP filter (Pacific Blue™ channel).
  • RFP_1-peakBI_2_080812
    Bead fluorescence at 488 nm excitation with a 530/30 BP filter (FITC channel).
  • RFP_1-peakBI_3_080812
    Bead fluorescence at 561 nm excitation with a 582/15 BP filter (PE channel).

    Rainbow Fluorescent Particles were analysed on a 4-laser BD LSRFortessa™ using detector voltages from a 15-color surface phenotyping assay identifying immune cell subsets in lysed whole blood.
Cat # Size Price Quantity Check Availability Save
422907 5 mL 231€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

These Rainbow Fluorescent Particles consist of uniformly sized particles dyed with a mixture of fluorophores. These particles produce a single peak with tight CV in each detection channel of conventional flow cytometers within the specified excitation range. Rainbow Fluorescent Particles can be used with most optical filters intended for analysis of fluorophores commonly used for flow cytometry. As the excitation range of these rainbow particles is 365 - 650 nm, they can be used with most lasers. However, they are not for use with the UV laser. The emission spectra of these rainbow particles is compatible with many common fluorophores used in immunofluorescent staining with flow cytometric analysis.

 

For standardization of cytometer detector settings between experiments, Rainbow Fluorescent Particles can be used to provide target channels to facilitate set up, ensuring data consistency in consequent runs.  Rainbow Fluorescent Particles are available in two intensity levels: Mid Range Intensity (Cat. No. 422905) and Bright Intensity (Cat. No. 422907), providing flexibility to accommodate samples with different levels of background fluorescence.

Product Details
Technical Data Sheet (pdf)

Product Details

Formulation
Rainbow Fluorescent Particles are in deionized water with 0.02% sodium azide and 0.01% NP-40.
Concentration
107 particles per ml.
Storage & Handling
Store between 2°C and 8°C. Do not freeze. Protect from light.
Application

FC

Recommended Usage

Resuspend well (e.g. vortex briefly) before adding 3-5 drops to 1 ml of filtered DI water.

Application Notes

Use of Rainbow Fluorescent Particles, 1 peak (3.0-3.4 µm) - Bright Range Intensity, is common for the following purposes:
1. Laser alignment
2. Standardization of instrument settings for longitudinal studies (can also use Fluorescent Calibration Particles, 1 peak, Mid Range Intensity (Cat. No. 422905) and multi-peak Rainbow Calibration Particles (Cat No. 422901 and 422903)

Application References
  1. Perfetto SP, et al. 2006. Nat. Protoc. 1:1522.

Antigen Details

Gene ID
NA

Related FAQs

There are no FAQs for this product.
Go To Top Version: 1    Revision Date: 11-30-2012

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account