Biotin anti-mouse CD117 (c-Kit) Antibody

Pricing & Availability
Clone
2B8 (See other available formats)
Regulatory Status
RUO
Other Names
c-KIT, Stem Cell Factor Receptor (SCFR)
Isotype
Rat IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
2B8_Biotin_1_112911
C57BL/6 mouse bone marrow cells were stained with B220 APC and biotinylated CD117 (clone 2B8) or rat IgG2b, κ isotype control, followed by Sav-PE.
  • 2B8_Biotin_1_112911
    C57BL/6 mouse bone marrow cells were stained with B220 APC and biotinylated CD117 (clone 2B8) or rat IgG2b, κ isotype control, followed by Sav-PE.
  • 2B8_Biotin_2_112911
Compare all formats
Cat # Size Price Quantity Check Availability Save
105803 50 µg 62€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
105804 500 µg 219€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD117 is a 145 kD immunoglobulin superfamily member also known as c-Kit and stem cell factor receptor (SCFR). It is a transmembrane tyrosine-kinase receptor that binds the c-Kit ligand (also known as steel factor, stem cell factor, and mast cell growth factor). CD117 is expressed on hematopoietic stem cells (including multipotent hematopoietic stem cells, progenitors committed to myeloid and/or erythroid lineages, and T and B cell precursors), mast cells, and acute myeloid leukemia (AML) cells. CD117 interaction with its ligand is critical for the development of hematopoietic stem cells.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Mouse bone marrow mast cells
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography, and conjugated with biotin under optimal conditions.
Concentration
0.5 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.25 µg per 106 cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Application Notes

Additional reported applications (for the relevant formats) include: immunoprecipitation1, immunohistochemistry of acetone fixed frozen sections2, and spatial biology (IBEX)5,6. The 2B8 antibody does not block c-Kit activity.

Application References

(PubMed link indicates BioLegend citation)
  1. Ikuta K, et al. 1992. P. Natl. Acad. Sci. USA 89:1502. (FC)
  2. Podd BS, et al. 2006. J. Immunol. 176:6532. PubMed (IHC)
  3. Bachelet I, et al. 2008. J. Immunol. 180:6064. PubMed (FC)
  4. Charles N, et al. 2010. Nat. Med. 16:701. PubMed (FC)
  5. Radtke AJ, et al. 2020. Proc Natl Acad Sci U S A. 117:33455-65. (SB) PubMed
  6. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed
Product Citations
  1. Drobek A, et al. 2015. J Immunol. 195: 3416 - 3426. PubMed
  2. Kuroki S, et al. 2020. Stem Cell Reports. 0.919444444. PubMed
  3. Gargaro M, et al. 2022. Immunity. 55:1032. PubMed
  4. Moore AR, et al. 2022. Cell Rep. 41:111651. PubMed
  5. Ye B, et al. 2022. Cell Mol Immunol. 19:619. PubMed
  6. Peng YJ, et al. 2023. Development. 150:. PubMed
  7. Larsen SB, et al. 2021. Cell Stem Cell. 28:1758. PubMed
  8. Yamamoto K, et al. 2021. Cell Reports. 36(8):109576. PubMed
  9. Onodera T, et al. 2019. J Immunol. 203:3282. PubMed
  10. Li Y, et al. 2020. Cell Stem Cell. 27(5):732-747.e7. PubMed
  11. Adam RC et al. 2018. Cell stem cell. 22(3):398-413 . PubMed
  12. Rai S, et al. 2014. PLoS One. 9:109441. PubMed
  13. Harnett MM, et al. 2022. Front Immunol. 13:953053. PubMed
  14. Onodera T, et al. 2021. Immunity. 54:2385. PubMed
  15. Kandalla P, et al. 2016. J Exp Med. 213: 2269 - 2279. PubMed
  16. Fujii T, et al. 2021. Bone Res. 9:4. PubMed
  17. Adachi Y, et al. 2019. Nat Commun. 10:3883. PubMed
  18. Laurin M, et al. 2019. Elife. 8. PubMed
  19. Miao Y et al. 2019. Cell. 177(5):1172-1186 . PubMed
  20. Bae S, et al. 2021. Cell Reports. 35(11):109264. PubMed
RRID
AB_313212 (BioLegend Cat. No. 105803)
AB_313212 (BioLegend Cat. No. 105804)

Antigen Details

Structure
Ig superfamily, 145 kD
Distribution

Hematopoietic stem cells, AML, mast cells

Function
Growth factor receptor, tyrosine kinase
Ligand/Receptor
Stem Cell Factor (SCF)
Cell Type
Embryonic Stem Cells, Hematopoietic stem and progenitors, Leukemia, Mast cells, Mesenchymal Stem Cells
Biology Area
Immunology, Stem Cells
Molecular Family
CD Molecules
Antigen References

1. Barclay A, et al. 1997. The Leukocyte Antigen FactsBook Academic Press.
2. Galli SJ, et al. 1994. Adv. Immunol. 55:1.
3. Ikuta K, et al. 1992. Annu. Rev. Immunol. 10:759.
4. Besmer P, et al. 1986. Nature 320:415.
5. Witte ON. 1990. Cell 63:5.

Gene ID
16590 View all products for this Gene ID
UniProt
View information about CD117 on UniProt.org

Related FAQs

How many biotin molecules are per antibody structure?
We don't routinely measure the number of biotins with our antibody products but the number of biotin molecules range from 3-6 molecules per antibody.

Other Formats

View All CD117 Reagents Request Custom Conjugation
Description Clone Applications
APC anti-mouse CD117 (c-Kit) 2B8 FC
Biotin anti-mouse CD117 (c-Kit) 2B8 FC
FITC anti-mouse CD117 (c-Kit) 2B8 FC
PE anti-mouse CD117 (c-Kit) 2B8 FC
PE/Cyanine5 anti-mouse CD117 (c-Kit) 2B8 FC
Purified anti-mouse CD117 (c-Kit) 2B8 FC,IHC-F
PE/Cyanine7 anti-mouse CD117 (c-Kit) 2B8 FC
Alexa Fluor® 488 anti-mouse CD117 (c-Kit) 2B8 FC,IHC-F
Alexa Fluor® 647 anti-mouse CD117 (c-Kit) 2B8 FC,IHC-F
Pacific Blue™ anti-mouse CD117 (c-Kit) 2B8 FC
PerCP/Cyanine5.5 anti-mouse CD117 (c-kit) 2B8 FC
PerCP anti-mouse CD117 (c-kit) 2B8 FC
APC/Cyanine7 anti-mouse CD117 (c-kit) 2B8 FC
Brilliant Violet 421™ anti-mouse CD117 (c-Kit) 2B8 FC,SB
Purified anti-mouse CD117 (c-Kit) (Maxpar® Ready) 2B8 FC,CyTOF®
PE/Dazzle™ 594 anti-mouse CD117 (c-Kit) 2B8 FC
Brilliant Violet 711™ anti-mouse CD117 (c-Kit) 2B8 FC
Alexa Fluor® 594 anti-mouse CD117 (c-Kit) 2B8 IHC-F,3D IHC
APC/Fire™ 750 anti-mouse CD117 (c-Kit) 2B8 FC
Brilliant Violet 510™ anti-mouse CD117 (c-Kit) 2B8 FC
Brilliant Violet 785™ anti-mouse CD117 (c-Kit) 2B8 FC
TotalSeq™-A0012 anti-mouse CD117 (c-kit) 2B8 PG
Brilliant Violet 605™ anti-mouse CD117 (c-Kit) 2B8 FC
Alexa Fluor® 700 anti-mouse CD117 (c-Kit) 2B8 FC
TotalSeq™-B0012 anti-mouse CD117 (c-Kit) 2B8 PG
TotalSeq™-C0012 anti-mouse CD117 (c-Kit) 2B8 PG
Spark NIR™ 685 anti-mouse CD117 (c-kit) 2B8 FC
Brilliant Violet 650™ anti-mouse CD117 (c-kit) 2B8 FC
Spark Red™ 718 anti-mouse CD117 (c-kit) (Flexi-Fluor™) 2B8 FC
Spark Blue™ 574 anti-mouse CD117 (c-kit) (Flexi-Fluor™) 2B8 FC
Spark Blue™ 550 anti-mouse CD117 (c-kit) (Flexi-Fluor™) 2B8 FC
Go To Top Version: 2    Revision Date: 06.28.2013

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account