Spark Blue™ 574 anti-mouse F4/80 (Flexi-Fluor™) Antibody

Pricing & Availability
Clone
BM8 (See other available formats)
Regulatory Status
RUO
Other Names
EMR1, Ly71
Isotype
Rat IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Save
285165 50 µg 269€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

F4/80, also known as EMR1 or Ly71, is a 160 kD glycoprotein of the epidermal growth factor (EGF)-transmembrane 7 (TM7) family. F4/80 has been widely used as a murine macrophage marker. It is expressed on a majority of tissue macrophages, including macrophages in the lung, gut, peritoneal cavity, thymus, and red pulp of the spleen, Kupffer cells, Langerhans cells, microglia, and certain dendritic cells. It is not expressed on macrophages located in the T cell areas of the spleen, lymph node, or Peyer's patch. The biological ligand of F4/80 has not been identified, but it has been reported that F4/80 is required for the induction of CD8+ T cells-mediated peripheral tolerance.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Murine macrophages
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark Blue™ 574 under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage

Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.

Excitation Laser
Blue Laser (488 nm)
Application Notes

Additional reported applications (for the relevant formats) include: immunohistochemical staining of acetone-fixed frozen sections1,2 and formalin-fixed paraffin-embedded sections6,7, Western blotting, and spatial biology (IBEX)12,13.

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References

(PubMed link indicates BioLegend citation)
  1. Schaller E, et al. 2002. Mol. Cell. Biol. 22:8035. (IHC)
  2. Stevceva L, et al. 2001. BMC Clin Pathol. 1:3. (IHC)
  3. Kobayashi M, et al.2008. J. Leukoc. Biol. 83:1354. PubMed
  4. Poeckel D, et al. 2009. J. Biol Chem. 284:21077. PubMed
  5. Glass AM, et al. 2013. J. Immunol. 190:4830. PubMed
  6. Koehm S, et al. 2007. J. Allergy Clin. Immunol. 120:570. (IHC)
  7. Rankin AL, et al. 2010. J. Immunol. 184:1526. (IHC)
  8. Sasi SP, et al. 2014. J Biol Chem. 289:14178. PubMed
  9. Thakus VS, et al. 2014. Toxicol Lett. 230:322. PubMed
  10. Watson NB, et al. 2015. J Immunol. 194:2796. PubMed
  11. Hirakawa H, et al. 2015. PLoS One. 10:119360. PubMed
  12. Radtke AJ, et al. 2020. Proc Natl Acad Sci U S A. 117:33455-65. (SB) PubMed
  13. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed
RRID
AB_3662505 (BioLegend Cat. No. 285165)

Antigen Details

Structure
EGF-TM7 family member, 160 kD glycoprotein
Distribution

Majority of tissue macrophages including peritoneal macrophages, macrophages in lung, gut, thymus and red pulp of spleen, Kupffer cells, Langerhans cells, bone marrow stromal cells, and a subset of dendritic cells

Function
Induction of immunological tolerance
Cell Type
Dendritic cells, Langerhans cells, Macrophages, Tregs
Biology Area
Cell Biology, Immunology, Innate Immunity, Neuroinflammation, Neuroscience
Antigen References

1. Austy JM and Gordon S. 1981. Eur. J. Immunol. 11:805.
2. Hume DA, et al. 1983. J. Exp. Med. 158:1522.
3. Ruedl C, et al. 1996. Eur. J. Immunol. 26:1801.
4. McKnight AJ, et al. 1996. J. Biol. Chem. 271:486.
5. Lin HH, et al. 2005. J. Exp. Med. 201:1615.

Gene ID
NA
UniProt
View information about F4/80 on UniProt.org

Related FAQs

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

Other Formats

View All F4/80 Reagents Request Custom Conjugation
Description Clone Applications
Brilliant Violet 605™ anti-mouse F4/80 BM8 FC
Purified anti-mouse F4/80 BM8 FC,IHC,WB
Biotin anti-mouse F4/80 BM8 FC,IHC
FITC anti-mouse F4/80 BM8 FC
PE anti-mouse F4/80 BM8 FC
PE/Cyanine5 anti-mouse F4/80 BM8 FC
PE/Cyanine7 anti-mouse F4/80 BM8 FC
APC anti-mouse F4/80 BM8 FC
APC/Cyanine7 anti-mouse F4/80 BM8 FC
Alexa Fluor® 488 anti-mouse F4/80 BM8 FC,IHC-F,3D IHC
Alexa Fluor® 647 anti-mouse F4/80 BM8 FC,IHC-F,3D IHC
Pacific Blue™ anti-mouse F4/80 BM8 FC
PerCP anti-mouse F4/80 BM8 FC
PerCP/Cyanine5.5 anti-mouse F4/80 BM8 FC
Alexa Fluor® 700 anti-mouse F4/80 BM8 FC
Brilliant Violet 421™ anti-mouse F4/80 BM8 FC,IHC-F,SB
Brilliant Violet 510™ anti-mouse F4/80 BM8 FC
Alexa Fluor® 594 anti-mouse F4/80 BM8 IHC-F
Brilliant Violet 785™ anti-mouse F4/80 BM8 FC
Purified anti-mouse F4/80 (Maxpar® Ready) BM8 FC,CyTOF®
PE/Dazzle™ 594 anti-mouse F4/80 BM8 FC
Brilliant Violet 650™ anti-mouse F4/80 BM8 FC
Brilliant Violet 711™ anti-mouse F4/80 BM8 FC
APC/Fire™ 750 anti-mouse F4/80 BM8 FC
TotalSeq™-A0114 anti-mouse F4/80 BM8 PG
TotalSeq™-B0114 anti-mouse F4/80 BM8 PG
TotalSeq™-C0114 anti-mouse F4/80 BM8 PG
Spark YG™ 570 anti-mouse F4/80 BM8 IHC-F
KIRAVIA Blue 520™ anti-mouse F4/80 BM8 FC
Ultra-LEAF™ Purified anti-mouse F4/80 BM8 FC,IHC,WB
APC/Fire™ 810 anti-mouse F4/80 BM8 FC
Spark NIR™ 685 anti-mouse F4/80 BM8 FC
Spark Blue™ 550 anti-mouse F4/80 BM8 FC
Brilliant Violet 570™ anti-mouse F4/80 BM8 FC
Brilliant Violet 750™ anti-mouse F4/80 BM8 FC
PE/Fire™ 810 anti-mouse F4/80 BM8 FC
Spark Red™ 718 anti-mouse F4/80 (Flexi-Fluor™) BM8 FC
Spark Blue™ 574 anti-mouse F4/80 (Flexi-Fluor™) BM8 FC
Go To Top Version: 1    Revision Date: 09.06.2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account