APC anti-mouse CD31 (PECAM-1) Antibody

Pricing & Availability
Clone
W18222B (See other available formats)
Regulatory Status
RUO
Other Names
PECAM-1, EndoCAM
Isotype
Rat IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
W18222B_APC_CD31_Antibody_120321
C57BL/6 mouse splenocytes were stained with anti-mouse CD3 Alexa Fluor® 488 and anti-mouse CD31 (clone W18222B) APC (left) or rat IgG2b, κ isotype control (right).
  • W18222B_APC_CD31_Antibody_120321
    C57BL/6 mouse splenocytes were stained with anti-mouse CD3 Alexa Fluor® 488 and anti-mouse CD31 (clone W18222B) APC (left) or rat IgG2b, κ isotype control (right).
Compare all formats See APC spectral data
Cat # Size Price Quantity Check Availability Save
160209 25 µg $90
Check Availability


Need larger quantities of this item?
Request Bulk Quote
160210 100 µg $305
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD31 is a 130-140 kD glycoprotein, also known as platelet endothelial cell adhesion molecule (PECAM-1) and EndoCAM. It is a member of the Ig superfamily, expressed on endothelial cells, platelets, granulocytes, monocytes/macrophages, dendritic cells, and T and B cell subsets, and is critical for cell-cell interactions. The primary ligands for CD31 have been reported to be CD38 and the vitronectin receptor (αv β3 integrin, CD51/CD61). Other reported functions of CD31 are neutrophil emigration to sites of inflammation and angiogenesis.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Mouse CD31 transfected cell line
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with APC under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality Tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.06 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application.

Excitation Laser
Red Laser (633 nm)
RRID
AB_2904305 (BioLegend Cat. No. 160209)
AB_2904305 (BioLegend Cat. No. 160210)

Antigen Details

Structure
Ig superfamily, 130-140 kD
Distribution

Endothelial cells, platelets, granulocytes, monocytes/macrophages, dendritic cells, T and B cell subsets

Function
Adhesion
Ligand/Receptor
CD38, αV3 integrin
Cell Type
B cells, Dendritic cells, Endothelial cells, Granulocytes, Macrophages, Monocytes, Neutrophils, Platelets, T cells
Biology Area
Angiogenesis, Cell Adhesion, Cell Biology, Immunology, Neuroinflammation, Neuroscience
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References
  1. Barclay AN, et al. 1997. The Leukocyte Antigen FactsBook Academic Press.
  2. DeLisser HM, et al. 1994. Immunol Today. 15:490-5.
  3. Newman PJ, et al. 1990. Science. 247:1219-22.
Gene ID
18613 View all products for this Gene ID
UniProt
View information about CD31 on UniProt.org

Related FAQs

There are no FAQs for this product.
Go To Top Version: 1    Revision Date: 12/03/2021

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account