Brilliant Violet 421™ anti-Tubulin Beta 3 (TUBB3) Antibody

Pricing & Availability
Clone
AA10 (See other available formats)
Regulatory Status
RUO
Other Names
β-3 Tubulin, Neuronal class III beta-tubulin, β3-tub
Isotype
Mouse IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
AA10_BV421_TUBB3_Antibody_1_ICC_080819
Human lung adenocarcinoma cell line A549 was fixed with 1% paraformaldehyde (PFA) for ten minutes, permeabilized with 0.5 % Triton X-100 for ten minutes, and blocked with 5% FBS for 30 minutes. Then, the tissue was stained with 2.5 µg/ml of Brilliant Violet 421™ anti-Tubulin Beta 3 (TUBB3) (clone AA10, blue) overnight at 4°C. Nuclei were counterstained with DRAQ5™ (red). The image was captured with a 40X objective.
  • AA10_BV421_TUBB3_Antibody_1_ICC_080819
    Human lung adenocarcinoma cell line A549 was fixed with 1% paraformaldehyde (PFA) for ten minutes, permeabilized with 0.5 % Triton X-100 for ten minutes, and blocked with 5% FBS for 30 minutes. Then, the tissue was stained with 2.5 µg/ml of Brilliant Violet 421™ anti-Tubulin Beta 3 (TUBB3) (clone AA10, blue) overnight at 4°C. Nuclei were counterstained with DRAQ5™ (red). The image was captured with a 40X objective.
  • AA10_BV421_TUBB3_Antibody_2_IHCF_080819
    C57BL/6 mouse frozen brain (cerebellum) tissue was fixed with 4% paraformaldehyde (PFA) for ten minutes, permeabilized with 0.5 % Triton X-100 for ten minutes, and blocked with 5% FBS for one hour. Then, the tissue was stained with 2.5 µg/ml of Brilliant Violet 421™ anti-Tubulin Beta 3 (TUBB3) (clone AA10, blue) and 5 µg/ml of Alexa Fluor® 488 anti-GFAP (clone 2E1.E9, green) in 5% FBS, overnight at 4°C. Nuclei were counterstained with DRAQ5™ (red). The image was captured with a 10X objective.
Compare all formats See Brilliant Violet 421™ spectral data
Cat # Size Price Quantity Check Availability Save
657412 100 µg $435
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Tubulin is the main component of microtubules. In adults, tubulin beta 3 (TUBB3) is primarily expressed in neurons and is commonly used as a neuronal marker. It plays an important role in neuronal cell proliferation and differentiation. Mutations in this gene cause congenital fibrosis of the type 3 extraocular muscles. Tubulin beta 3 (TUBB3) is also found in a wide range of tumors. Studies indicate that it is a predictive and prognostic marker in various tumors.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Mouse, Rat, Human
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Fusion protein
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA).
Preparation
The antibody was purified by affinity chromatography and conjugated with Brilliant Violet 421™ under optimal conditions.
Concentration
0.2 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

IHC-F - Quality tested
ICC - Verified

SB - Reported in the literature, not verified in house

Recommended Usage

Each lot of this antibody is quality control tested by immunohistochemical staining on frozen tissue sections. For immunohistochemical staining on frozen tissue sections, the suggested use of this reagent is 1.25 - 5.0 µg/ml. For immunocytochemistry, a concentration range of 1.25 - 5.0 μg/ml is recommended. It is recommended that the reagent be titrated for optimal performance for each application.

Brilliant Violet 421™ excites at 405 nm and emits at 421 nm. The standard bandpass filter 450/50 nm is recommended for detection. Brilliant Violet 421™ is a trademark of Sirigen Group Ltd.


Learn more about Brilliant Violet™.

This product is subject to proprietary rights of Sirigen Inc. and is made and sold under license from Sirigen Inc. The purchase of this product conveys to the buyer a non-transferable right to use the purchased product for research purposes only. This product may not be resold or incorporated in any manner into another product for resale. Any use for therapeutics or diagnostics is strictly prohibited. This product is covered by U.S. Patent(s), pending patent applications and foreign equivalents.
Excitation Laser
Violet Laser (405 nm)
Application Notes

Additional reported application (for relevant formats) include: spatial biology (IBEX)1,2.

Additional Product Notes

Iterative Bleaching Extended multi-pleXity (IBEX) is a fluorescent imaging technique capable of highly-multiplexed spatial analysis. The method relies on cyclical bleaching of panels of fluorescent antibodies in order to image and analyze many markers over multiple cycles of staining, imaging, and, bleaching. It is a community-developed open-access method developed by the Center for Advanced Tissue Imaging (CAT-I) in the National Institute of Allergy and Infectious Diseases (NIAID, NIH).

Application References

(PubMed link indicates BioLegend citation)
  1. Radtke AJ, et al. 2020. Proc Natl Acad Sci U S A. 117:33455-65. (SB) PubMed
  2. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed
RRID
AB_2632699 (BioLegend Cat. No. 657412)

Antigen Details

Structure
450 amino acids with predicted molecular weight of 50 kD
Distribution

Cytosol

Function
Plays important roles in neuronal cell proliferation and differentiation
Interaction
Alpha tubulin, kinesin and dynein
Cell Type
Mature Neurons
Biology Area
Cell Biology, Cell Cycle/DNA Replication, Cell Motility/Cytoskeleton/Structure, Immunology, Neuroscience, Neuroscience Cell Markers
Molecular Family
Microtubules
Antigen References

1. Katsetos CD, et al. 2003. J. Child Neurol. 18:851.
2. Mobarakeh ZT, et al. 2012. Cell Biol. Int. Rep. (2010) 19:e00015.
3. Locher H, et al. 2013. Differentiation. 85:173.
4. Karki R, et al. 2013. Expert Opin. Ther. Targets. 17:461.
5. Mariani M, et al. 2011. Curr. Mol. Med. 11:726.
6. Koh Y, et al. 2009. Ann. Oncol. 20:1414.

Gene ID
10381 View all products for this Gene ID
UniProt
View information about Tubulin beta-3 on UniProt.org

Related FAQs

What is the F/P ratio range of our BV421™ format antibody reagents?

It is lot-specific. On average it ranges between 2-4.

If an antibody clone has been previously successfully used in IBEX in one fluorescent format, will other antibody formats work as well?

It’s likely that other fluorophore conjugates to the same antibody clone will also be compatible with IBEX using the same sample fixation procedure. Ultimately a directly conjugated antibody’s utility in fluorescent imaging and IBEX may be specific to the sample and microscope being used in the experiment. Some antibody clone conjugates may perform better than others due to performance differences in non-specific binding, fluorophore brightness, and other biochemical properties unique to that conjugate.

Will antibodies my lab is already using for fluorescent or chromogenic IHC work in IBEX?

Fundamentally, IBEX as a technique that works much in the same way as single antibody panels or single marker IF/IHC. If you’re already successfully using an antibody clone on a sample of interest, it is likely that clone will have utility in IBEX. It is expected some optimization and testing of different antibody fluorophore conjugates will be required to find a suitable format; however, legacy microscopy techniques like chromogenic IHC on fixed or frozen tissue is an excellent place to start looking for useful antibodies.

Are other fluorophores compatible with IBEX?

Over 18 fluorescent formats have been screened for use in IBEX, however, it is likely that other fluorophores are able to be rapidly bleached in IBEX. If a fluorophore format is already suitable for your imaging platform it can be tested for compatibility in IBEX.

The same antibody works in one tissue type but not another. What is happening?

Differences in tissue properties may impact both the ability of an antibody to bind its target specifically and impact the ability of a specific fluorophore conjugate to overcome the background fluorescent signal in a given tissue. Secondary stains, as well as testing multiple fluorescent conjugates of the same clone, may help to troubleshoot challenging targets or tissues. Using a reference control tissue may also give confidence in the specificity of your staining.

How can I be sure the staining I’m seeing in my tissue is real?

In general, best practices for validating an antibody in traditional chromogenic or fluorescent IHC are applicable to IBEX. Please reference the Nature Methods review on antibody based multiplexed imaging for resources on validating antibodies for IBEX.

Go To Top Version: 4    Revision Date: 09/13/2023

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account