GMP PE anti-human CD24 Antibody

Pricing & Availability
Clone
ML5 (See other available formats)
Workshop
V CD24.5
Other Names
Ly-52, Heat Stable Antigen (HSA), Nectadrin, BA-1
Isotype
Mouse IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
ML5_GMP-PE_CD24_Antibody_082622
Typical results from human peripheral blood lymphocytes stained either with ML5 PE used at 5 µL/test (filled histogram) or with an isotype control (open histogram).
  • ML5_GMP-PE_CD24_Antibody_082622
    Typical results from human peripheral blood lymphocytes stained either with ML5 PE used at 5 µL/test (filled histogram) or with an isotype control (open histogram).
Compare all formats See GMP PE spectral data
Cat # Size Price Quantity Check Availability Save
260166 100 tests $286
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD24 is a 35-45 kD glycosylphosphatidylinositol (GPI)-linked protein also known as heat stable antigen (HSA), BA-1, Ly-52, and nectadrin. It is expressed on the surface of B cells (but not plasma cells), granulocytes, follicular dendritic cells, and epithelial cells. CD24 may play a role in the regulation of B-cell proliferation and maturation. CD24 crosslinking induces a Ca2+ flux in mature B cells. CD24 has been shown to interact with CD62P (P-selectin).

Product Details
Technical data sheet

Product Details

Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and 0.2% (w/v) BSA (origin USA) and a stabilizer
Preparation
The antibody was purified by affinity chromatography and conjugated with PE under optimal conditions.
Concentration
200 µg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

Excitation Laser
Blue Laser (488 nm)
Green Laser (532 nm)/Yellow-Green Laser (561 nm)
Application Notes

Additional reported applications (for the relevant formats) include: immunofluorescence microscopy3.

Application References

(PubMed link indicates BioLegend citation)
  1. Schlossman S, et al. Eds. 1995. Leukocyte Typing V:White Cell Differentiation Antigens. Oxford University Press. New York.
  2. McMichael A, et al. 1987. Leucocyte Typing III. Oxford University Press. New York.
  3. Yang GP, et al. 1999. Nucleic Acids Research 27:1517. (IF)
  4. Kristiansen G, et al. 2003. Clin. Cancer Res. 9:4906. (FC)
Disclaimer

GMP RUO Flow Cytometry Antibodies. BioLegend GMP RUO fluorophore conjugated antibodies are manufactured in a dedicated GMP facility and compliant with ISO 13485:2016. For research use only. Not for use in diagnostic or therapeutic procedures. Our processes include:

  • Batch-to-batch consistency
  • Material traceability
  • Documented procedures
  • Documented employee training
  • Equipment maintenance and monitoring records
  • Lot-specific certificates of analysis
  • Quality audits per ISO 13485:2016
  • QA review of released products

Antigen Details

Structure
GPI-linked glycoprotein, 35-45 kD
Distribution

B cells, granulocytes, epithelial cells

Function
B cell proliferation and differentiation
Ligand/Receptor
CD62P (P-Selectin)
Cell Type
B cells, Epithelial cells, Granulocytes
Biology Area
Immunology
Molecular Family
CD Molecules
Antigen References

1. Schlossman S, et al. Eds. 1995. Leukocyte Typing V. Oxford University Press. New York.

Gene ID
100133941 View all products for this Gene ID
UniProt
View information about CD24 on UniProt.org

Related FAQs

What type of PE do you use in your conjugates?
We use R-PE in our conjugates.
Go To Top Version: 1    Revision Date: 09/19/2022

For Research Use Only. Suitable for ex vivo cell processing. Not for injection or diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account